66 resultados para Apnea Monitors

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the hypothesis that day/night patterns of prothrombotic activity differ between patients with obstructive sleep apnea (OSA) and individuals with no OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is aimed at addressing the current state of the art in epidemiology, pathophysiology, diagnostic procedures and treatment options for appropriate management of obstructive sleep apnea (OSA) in cardiovascular (particularly hypertensive) patients, as well as for the management of cardiovascular diseases (particularly arterial hypertension) in OSA patients. The present document is the result of the work done by a panel of experts participating in the European Union COST (COoperation in Scientific and Technological research) ACTION B26 on OSA, with the endorsement of the European Respiratory Society (ERS) and the European Society of Hypertension (ESH). These recommendations are particularly aimed at reminding cardiovascular experts to consider the occurrence of sleep-related breathing disorders in patients with high blood pressure. They are at the same time aimed at reminding respiration experts to consider the occurrence of hypertension in patients with respiratory problems at night.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent case reports have alerted the medical community of fatality in children receiving codeine after tonsillectomy and/or adenoidectomy for obstructive sleep apnea syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obstructive sleep apnea (OSA) has been associated with an increased risk of atherothrombotic events. A prothrombotic state might partially explain this link. This study investigated OSA patients' day/night rhythm of several prothrombotic markers and their potential changes with therapeutic continuous positive airway pressure (CPAP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A few publications documented the coexistence of epilepsy and obstructive sleep apnea (OSA). The extent, nature, and clinical relevance of this association remain poorly understood. We retrospectively reviewed the database of our sleep center to identify patients with both sleep apnea and epilepsy. Characteristics of epilepsy, sleep history, presence of excessive daytime sleepiness [Epworth Sleepiness Scale (ESS)] and polysomnographic data were assessed. The effect of continuous positive airway pressure (CPAP) on seizure reduction was prospectively analyzed after a median interval of 26 months (range: 2-116 months) from the diagnosis of OSA. OSA was found in 29 epilepsy patients (25 men and 4 women) with a median age of 56 years (range: 37-79). The median apnea hypopnea index was 33 (range: 10-85), the oxygen desaturation index was 12 (range 0-92), and 52% of the patients had an ESS score >10. In 27 patients, epilepsy appeared 1 month to 44 years prior to the diagnosis of OSA. In 21 patients, the appearance of OSA symptoms coincided with a clear increase in seizure frequency or the first appearance of a status epilepticus. Treatment with CPAP was continued with good compliance in 12 patients and led to a significant reduction of both ESS scores and seizure frequency in 4 patients. Our data suggest the importance of considering diagnosis and treatment of OSA in epilepsy patients with poor seizure control and/or reappearance of seizures after a seizure-free interval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prothrombotic state may contribute to the elevated cardiovascular risk in patients with obstructive sleep apnea (OSA). We investigated the relationship between apnea severity and hemostasis factors and effect of continuous positive airway pressure (CPAP) treatment on hemostatic activity. We performed full overnight polysomnography in 44 OSA patients (mean age 47+/-10 years), yielding apnea-hypopnea index (AHI) and mean nighttime oxyhemoglobin saturation (SpO2) as indices of apnea severity. For treatment, subjects were double-blind randomized to 2 weeks of either therapeutic CPAP (n = 18), 3 l/min supplemental nocturnal oxygen (n = 16) or placebo-CPAP (<1 cm H2O) (n = 10). Levels of von Willebrand factor antigen (VWF:Ag), soluble tissue factor (sTF), D-dimer, and plasminogen activator inhibitor (PAI)-1 antigen were measured in plasma pre- and posttreatment. Before treatment, PAI-1 was significantly correlated with AHI (r = 0.47, p = 0.001) and mean nighttime SpO2 (r = -0.32, p = 0.035), but these OSA measures were not significantly related with VWF:Ag, sTF, and D-dimer. AHI was a significant predictor of PAI-1 (R2 = 0.219, standardized beta = 0.47, p = 0.001), independent of mean nighttime SpO2, body mass index (BMI), and age. A weak time-by-treatment interaction for PAI-1 was observed (p = 0.041), even after adjusting for age, BMI, pre-treatment AHI, and mean SpO2 (p = 0.046). Post hoc analyses suggested that only CPAP treatment was associated with a decrease in PAI-1 (p = 0.039); there were no changes in VWF:Ag, sTF, and D-dimer associated with treatment with placebo-CPAP or with nocturnal oxygen. Apnea severity may be associated with impairment in the fibrinolytic capacity. To the extent that our sample size was limited, the observation that CPAP treatment led to a decrease in PAI-1 in OSA must be regarded as tentative.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Due to the increasing importance of quality of life assessments in obstructive sleep apnea (OSA) patients and due to an increased use of the International Classification of Functioning, Disability and Health (ICF), for comparative purposes it is essential to understand the relationship between health-related quality of life (HRQOL) instruments and the ICF. The purpose of this study was to compare the content covered by OSA-specific instruments using the ICF. PATIENTS AND METHODS: OSA-specific instruments were identified, including the Calgary Sleep Apnea Quality of Life Index, the Functional Outcomes of Sleep Questionnaire, the Obstructive Sleep Apnea Patient-Oriented Severity Index, and the Quebec Sleep Questionnaire, and linked to the ICF by six health professionals according to standardized guidelines. The degree of agreement between health professionals was calculated by means of the kappa statistic. RESULTS: A total of 308 concepts were identified and linked to 78 different ICF categories; 35 categories of the component body function, one category of the component body structure, 38 categories of the component activities and participation, and four categories of the component environmental factors. Only contents within the chapters mental functions, mobility and social life were addressed by all instruments. Forty-seven categories were covered by only one instrument. CONCLUSION: The ICF proved highly useful for the comparison of HRQOL instruments. This analysis may help researchers and clinicians to choose the most appropriate HRQOL instrument for a specific purpose as well as help to compare study outcomes of studies using different instruments for HRQOL assessment.