8 resultados para Apertureless aplanatic lens

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report on the outcome of combined pars plana phacofragmentation, vitrectomy, and Artisan lens implantation in the management of subluxated cataracts. METHODS: This prospective, interventional, nonrandomized case series included nine eyes of seven consecutive adult patients with traumatic lens subluxation. Pre- and postoperative data (complete manifest refraction, best spectacle-corrected visual acuity, slit-lamp examination findings, intraocular pressure, fundus status, numerical density of endothelial cells, corneal thickness, and complications) were collected prospectively for all patients. RESULTS: After a median postoperative follow-up of 12 months (range, 8-18 months), a mean spherical equivalent of -0.50 +/- 0.87 diopter (range, +1 to -1.50 diopter) was achieved. The mean logarithm of the minimum angle of resolution visual acuity improved from 1 (preoperatively) to 0.1 (postoperatively) (P = 0.007, Wilcoxon test). Median endothelial cell losses of 15 +/- 8% (P = 0.008) and 14 +/- 16% (P = 0.011) were registered at follow-ups of 1 month and 12 months, respectively. Postoperative complications included chronic intraocular inflammation and superior corectopia. CONCLUSIONS: Our procedure appears to be a safe, accurate, stable, and efficacious option for the management of traumatic subluxated cataracts in adults. However, longer-term data are needed to evaluate the corneal endothelium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PurposeTo investigate the causal relationship between acute postoperative endophthalmitis (POE) after cataract surgery and the biomaterial properties of the intraocular lens (IOLs) implanted.MethodsThis retrospective cohort study included all patients who had undergone cataract surgery with IOL implantation at the Lyon Croix-Rousse University Hospital between 1st January 1994 and 31st December 2004. Details respecting the type of IOL implanted (material and manufacturer) were meticulously recorded. The number of patients presenting with POE within 6 weeks of cataract surgery was documented together with their medical characteristics. These data were then compared, and Fisher's exact test was used to establish the significance of any apparent associations.ResultsEight of the 5837 eyes manifested acute POE (0.14%). Seven of these were composed of polymethylmethacrylate (PMMA) and one of heparinized PMMA. Patients with PMMA IOLs carried a higher risk of developing POE than did those implanted with either heparinized PMMA (P=0.001), hydrophilic acrylic, or hydrophobic acrylic IOLs (P=0.002).ConclusionsThe incidence of acute POE after cataract surgery in our hospital is similar to that currently reported for other institutions in developed countries. Our results add further evidence that IOL material and type are factors contributing to the risk to develop an acute POE after cataract surgery, and that PMMA IOLs may be associated with an increased risk of POE.Eye advance online publication, 15 September 2006; doi:10.1038/sj.eye.6702544.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study presents an evaluation of the preoperative and postoperative best corrected visual acuity (BCVA), as well as of the incidence of perioperative and postoperative complications after opacified hydrogel intraocular lens (IOL) exchange. PATIENTS AND METHODS: We exchanged opacified hydrogel IOLs (Hydroview H 60 M, Bausch ; Lomb) in 55 patients (55 eyes). Preoperative and postoperative BCVA were compared. Intraoperative and postoperative complications were recorded. Follow-up period ranged from 3 months to 24 months. RESULTS: Mean BCVA improved significantly from 0.05 preoperatively to 0.4 at 3 months postoperatively and to 0.2 at the end of the follow-up period. Forty patients (72.7 %) reported visual improvement. The procedure was uneventful in 30 eyes (54.5 %) with complete removal of the opacified IOL optics and haptics. Intraoperative complications included partial zonular dehiscence in 10 eyes (18.2 %), en block capsular bag-IOL extraction in 2 eyes (3.6 %), posterior capsule rupture in 2 eyes (3.6 %), hyphema in 3 eyes (5.5 %), retained haptics in 8 eyes (14.5 %). Postoperative complications included corneal decompensation in 5 eyes (9.1 %), cystoid macular edema in 15 eyes (27.3 %), elevated intraocular pressure in 6 eyes (10.9 %), and retinal detachment in 1 eye (1.8 %). CONCLUSIONS: Visual acuity improved after opacified hydrogel IOL exchange, however, coexistent ocular morbidity as well as the appearance of serious postoperative complications may not yield the expected results. For these reasons extensive informed consent is mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To report the incidence of anterior capsule contraction syndrome (ACCS) and to present a novel minimally invasive bimanual technique for anterior segment revision surgery associated with ACCS with anterior flexion of the intraocular lens haptics. METHODS A consecutive cohort of 268 eyes of 161 patients undergoing phacoemulsification and implantation of the same type of hydrophilic acrylic aspheric intraocular lens cohort were analysed and a novel technique of minimally invasive bimanual technique for anterior segment revision surgery is described. RESULTS We identified four eyes (1.5%) of three patients with advanced ACCS. Successful restoration of a clear visual axis with minimal induction of astigmatism and rapid visual rehabilitation was achieved in all four cases. CONCLUSION This technique is a safe and minimally invasive alternative to laser or vitrector-cut capsulotomy to restore a clear visual axis. In cases of advanced ACCS, it offers the option for haptic reposition or amputation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sanitation has evolved from a purely technical discipline to one that includes social, environmental, economic and, increasingly, gender considerations. However, blurry notions of gender are frequently offered in the sanitation literature. Although it has been recognized that gender-responsive sanitation does not mean ‘toilets for women’, substantial alternatives are rarely debated. We structure our review of sanitation in developing countries along three lines: we start by fine-tuning the concept of gender both from the academic and the practitioner's perspective, analyse relevant developments in gender-specific policies and programming, and finally review the most appropriate toilet room and menstrual hygiene technologies. We argue that strategies to make technologies gender-responsive need to be based upon a thorough analysis of the social arrangements of the intimate, and how these are negotiated and institutionalized in a specific context. A lack of robust gender-segregated data on sanitation policies and technologies, along with reductionist framings of gender are to blame for limited progress in verifying the need for, and impact of, gender-responsive sanitation. Technology and policy development and implementation would benefit from gender-considerate interpretations of shame, dignity, safety and status. Further progress could be achieved by improving the translation process between different academic framings of the sanitation crisis. Keywords: appropriate technology; development; gender; menstrual hygiene management (MHM); sanitation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Starting from the early descriptions of Kraepelin and Bleuler, the construct of schizotypy was developed from observations of aberrations in nonpsychotic family members of schizophrenia patients. In contemporary diagnostic manuals, the positive symptoms of schizotypal personality disorder were included in the ultra high-risk (UHR) criteria 20 years ago, and nowadays are broadly employed in clinical early detection of psychosis. The schizotypy construct, now dissociated from strict familial risk, also informed research on the liability to develop any psychotic disorder, and in particular schizophrenia-spectrum disorders, even outside clinical settings. Against the historical background of schizotypy it is surprising that evidence from longitudinal studies linking schizotypy, UHR, and conversion to psychosis has only recently emerged; and it still remains unclear how schizotypy may be positioned in high-risk research. Following a comprehensive literature search, we review 18 prospective studies on 15 samples examining the evidence for a link between trait schizotypy and conversion to psychosis in 4 different types of samples: general population, clinical risk samples according to UHR and/or basic symptom criteria, genetic (familial) risk, and clinical samples at-risk for a nonpsychotic schizophrenia-spectrum diagnosis. These prospective studies underline the value of schizotypy in high-risk research, but also point to the lack of evidence needed to better define the position of the construct of schizotypy within a developmental psychopathology perspective of emerging psychosis and schizophrenia-spectrum disorders