26 resultados para Aorta -- Enfermedades

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aberrant origin of a pulmonary artery from the ascending aorta is an uncommon congenital vascular malformation with poor survival without surgery. In this case report, we describe the unusual late diagnosis of this congenital malformation in an otherwise asymptomatic young man presenting with mild hemoptysis. We review the natural and modified history of this defect and the relevant aspects of follow-up in adult life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated long-term results of thoracic endovascular aortic repair for atherosclerotic aneurysms involving descending aorta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Midterm results of TEVAR (thoracic endovascular aortic repair) in patients with aneurysms involving the descending aorta originating from chronic type B dissections are not known.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aims to identify risk constellations for symptomatic spinal cord malperfusion in patients undergoing extensive stent-graft coverage of the thoracic aorta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is not well known if the size of the ascending thoracic aorta at presentation predicts features of presentation, management, and outcomes in patients with acute type B aortic dissection. The International Registry of Acute Aortic Dissection (IRAD) database was queried for all patients with acute type B dissection who had documentation of ascending thoracic aortic size at time of presentation. Patients were categorized according to ascending thoracic aortic diameters ≤4.0, 4.1 to 4.5, and ≥4.6 cm. Four hundred eighteen patients met inclusion criteria; 291 patients (69.6%) were men with a mean age of 63.2 ± 13.5 years. Ascending thoracic aortic diameter ≤4.0 cm was noted in 250 patients (59.8%), 4.1 to 4.5 cm in 105 patients (25.1%), and ≥4.6 cm in 63 patients (15.1%). Patients with an ascending thoracic aortic diameter ≥4.6 cm were more likely to be men (p = 0.01) and have Marfan syndrome (p <0.001) and known bicuspid aortic valve disease (p = 0.003). In patients with an ascending thoracic aorta ≥4.1 cm, there was an increased incidence of surgical intervention (p = 0.013). In those with an ascending thoracic aorta ≥4.6 cm, the root, ascending aorta, arch, and aortic valve were more often involved in surgical repair. Patients with an ascending thoracic aorta ≤4.0 were more likely to have endovascular therapy than those with larger ascending thoracic aortas (p = 0.009). There was no difference in overall mortality or cause of death. In conclusion, ascending thoracic aortic enlargement in patients with acute type B aortic dissection is common. Although its presence does not appear to predict an increased risk of mortality, it is associated with more frequent open surgical intervention that often involves replacement of the proximal aorta. Those with smaller proximal aortas are more likely to receive endovascular therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracic endovascular aortic repair has broadened the spectrum of treatment options for various acute and chronic thoracic aortic diseases. In clinical practice, aneurysms of the descending aorta are rarely limited to 1 segment. Thus, various surgical and endovascular options have been developed to offer treatment to those patients with more extended descending thoracic aortic disease. We have summarized the most common methods of arch rerouting, depending on the aortic involvement, emphasizing that these techniques should be used very selectively by experienced cardiovascular surgery teams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 77-year-old woman underwent aortic valve replacement and coronary bypass grafting in 2007 in the Emirates. Evolution was uneventful until December 2011. After repeated episodes of unspecific infections, a computed tomographic scan showed a large pseudoaneurysm of the distal ascending aorta. The site of aortic rupture was closed with a Gore-Tex patch and a Staphylococcus aureus infection treated appropriately. Two months later, a small cutaneous lesion on the cranial part of the sternotomy started bleeding. Computed tomographic scan demonstrated recurrence of a false aneurysm with erosion of the sternum and a large subcutaneous hematoma caused by the fistula. The patient was transferred to our institution. The challenges of this case included safe surgical approach (sternotomy, cannulation, perfusion, cerebral protection) as well as complete removal and extensive debridement of the infected material and reconstruction of the aortic arch. Using fully biological material, reconstruction of the ascending aorta and proximal arch was successfully performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adult-type Pompe's disease (glycogen storage disease type II) has rarely been shown to present with dilatative arteriopathy, suggesting potential smooth muscle involvement in addition to lysosomal glycogen deposits usually restricted to skeletal muscle tissue. We report the case of a middle-aged man under enzyme replacement therapy presenting with an exceedingly large thoracic aortic aneurysm. Surprisingly, the histological work-up of resected aortic tissue revealed changes mimicking those observed in patients with classic connective tissue diseases. Enzyme replacement therapy, in addition to musculoskeletal and pulmonary treatment for patients with Pompe's disease, may prolong survival and lead to patients presenting with vascular alterations that may pose surgical and potential diagnostic challenges in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural abnormalities of the medial aorta have been described for conotruncal defects (e.g., tetralogy of Fallot [TOF] and complete transposition of the great arteries (dextrotransposition [d]-TGA). In TOF, progressive aortic dilation is a frequent finding. In patients with d-TGA with an atrial switch, this problem is less often described. The aim of the present study was to compare the extent of dilative aortopathy and aortic distensibility in adults with an atrial switch procedure (n = 39) to that in adults with repaired TOF (n = 39) and controls (n = 39), using cardiac magnetic resonance imaging. The groups were matched for age and gender. Diameters of the aorta indexed to the body surface area were significantly increased in the patients with d-TGA and TOF compared to that of the controls at the aortic sinus up to the level of the right pulmonary artery. On multivariate testing, the diagnosis of a conotruncal defect (β = 0.260; p = 0.003) and aortic regurgitant fraction (β = 0.405; p <0.001) were independent predictors of an increased aortic sinus diameter. Ascending aorta distensibility was significantly reduced in those with d-TGA and TOF compared to controls: 3.6 (interquartile range 1.5 to 4.4) versus 2.8 (interquartile range 2.0 to 3.7) versus 5.5 (interquartile range 4.8 to 6.9) ×10(-3) mm Hg(-1) (p <0.001). The independent predictors of ascending aorta distensibility were the diagnosis of a conotruncal defect (p <0.001) and age (p = 0.028). In conclusion, intrinsic aortopathy, manifested as increased ascending aortic diameters and reduced ascending aortic distensibility, is not only evident in adults with TOF, but also in adults with d-TGA and an atrial switch procedure. Long-term follow-up is needed to monitor the aortic size in both patient groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Autopsy determination of fatal hemorrhage as the cause of death is often a difficult diagnosis in forensic medicine. No quantitative system for accurately measuring the blood volume in a corpse has been developed. MATERIALS AND METHODS: This article describes the measurement and evaluation of the cross-sectional areas of major blood vessels, of the diameter of the right pulmonary artery, of the volumes of thoracic aorta and spleen on MDCT, and of the volumes of heart chambers on MRI in 65 autopsy-verified cases of fatal hemorrhage or no fatal hemorrhage. RESULTS: Most cases with a cause of death of "fatal hemorrhage" had collapsed vessels. The finding of a collapsed superior vena cava, main pulmonary artery, or right pulmonary artery was 100% specific for fatal hemorrhage. The mean volumes of the thoracic aorta and of each of the heart chambers and the mean cross-sectional areas of all vessels except the inferior vena cava and abdominal aorta were significantly smaller in fatal hemorrhage than in no fatal hemorrhage. CONCLUSION: For the quantitative differentiation of fatal hemorrhage from other causes of death, we propose a three-step algorithm with measurements of the diameter of the right pulmonary artery, the cross-sectional area of the main pulmonary artery, and the volume of the right atrium (specificity, 100%; sensitivity, 95%). However, this algorithm must be corroborated in a prospective study, which would eliminate the limitations of this study. Quantitative postmortem cross-sectional imaging might become a reliable objective method to assess the question of fatal hemorrhage in forensic medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of complex aortic pathologies involving the ascending aorta, the aortic arch, and the descending aorta remains a challenging issue in aortic surgery. The frozen elephant trunk procedure effectively combines surgical and interventional technologies in the treatment of extensive aortic aneurysms and dissections. We present two patients with complex aortic lesions involving all three segments of the thoracic aorta. The device used in our series is the new E-vita open hybrid prosthesis consisting of a proximal woven polyester tube and a distal self-expandable nitinol stent graft, which can be delivered antegrade into the descending aorta.