7 resultados para Ammunition containers

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In den Jahren 2001 bis 2007 ist bei den Polizeien der deutschen Bundesländer und bei den Polizeikorps der Schweiz die so genannte Polizeimunition eingeführt worden. Von dieser mit einem deformierenden Geschoss ausgerüsteten Munition verspricht man sich eine größere Wirksamkeit und wegen der begrenzten Durchschlagsleistung eine geringere Gefährdung unbeteiligter Personen. Bei geringerer Auftreffenergie deformiert sich jedoch das Geschoss weniger, die Wirksamkeit wird kleiner und die Eindringtiefe größer. In der hier vorgestellten Arbeit wurde die Abhängigkeit der Deformation und der Eindringtiefe in ballistische Seife von der Auftreffenergie für alle 4 gegenwärtig vorhandenen Polizeigeschosse untersucht. Bereits bei Schussdistanzen von 25–30 m ist mit einer verminderten Wirksamkeit zu rechnen. Bei einer viel gebrauchten Waffe kann zudem die Mündungsenergie so stark reduziert sein, dass sich bereits bei kurzen Schussdistanzen die Geschosse nicht mehr erwartungsgemäß deformieren.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The stable isotopic composition of fossil resting eggs (ephippia) of Daphnia spp. is being used to reconstruct past environmental conditions in lake ecosystems. However, the underlying assumption that the stable isotopic composition of the ephippia reflects the stable isotopic composition of the parent Daphnia, of their diet and of the environmental water have yet to be confirmed in a controlled experimental setting. We performed experiments with Daphnia pulicaria cultures, which included a control treatment conducted at 12 °C in filtered lake water and with a diet of fresh algae and three treatments in which we manipulated the stable carbon isotopic composition (δ13C value) of the algae, stable oxygen isotopic composition (δ18O value) of the water and the water temperature, respectively. The stable nitrogen isotopic composition (δ15N value) of the algae was similar for all treatments. At 12 °C, differences in algal δ13C values and in δ18O values of water were reflected in those of Daphnia. The differences between ephippia and Daphnia stable isotope ratios were similar in the different treatments (δ13C: +0.2 ± 0.4 ‰ (standard deviation); δ15N: −1.6 ± 0.4 ‰; δ18O: −0.9 ± 0.4 ‰), indicating that changes in dietary δ13C values and in δ18O values of water are passed on to these fossilizing structures. A higher water temperature (20 °C) resulted in lower δ13C values in Daphnia and ephippia than in the other treatments with the same food source and in a minor change in the difference between δ13C values of ephippia and Daphnia (to −1.3 ± 0.3 ‰). This may have been due to microbial processes or increased algal respiration rates in the experimental containers, which may not affect Daphnia in natural environments. There was no significant difference in the offset between δ18O and δ15N values of ephippia and Daphnia between the 12 and 20 °C treatments, but the δ18O values of Daphnia and ephippia were on average 1.2 ‰ lower at 20 °C than at 12 °C. We conclude that the stable isotopic composition of Daphnia ephippia provides information on that of the parent Daphnia and of the food and water they were exposed to, with small offsets between Daphnia and ephippia relative to variations in Daphnia stable isotopic composition reported from downcore studies. However, our experiments also indicate that temperature may have a minor influence on the δ13C, δ15N and δ18O values of Daphnia body tissue and ephippia. This aspect deserves attention in further controlled experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In an effort to reduce firearm mortality rates in the USA, US states have enacted a range of firearm laws to either strengthen or deregulate the existing main federal gun control law, the Brady Law. We set out to determine the independent association of different firearm laws with overall firearm mortality, homicide firearm mortality, and suicide firearm mortality across all US states. We also projected the potential reduction of firearm mortality if the three most strongly associated firearm laws were enacted at the federal level. METHODS We constructed a cross-sectional, state-level dataset from Nov 1, 2014, to May 15, 2015, using counts of firearm-related deaths in each US state for the years 2008-10 (stratified by intent [homicide and suicide]) from the US Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System, data about 25 firearm state laws implemented in 2009, and state-specific characteristics such as firearm ownership for 2013, firearm export rates, and non-firearm homicide rates for 2009, and unemployment rates for 2010. Our primary outcome measure was overall firearm-related mortality per 100 000 people in the USA in 2010. We used Poisson regression with robust variances to derive incidence rate ratios (IRRs) and 95% CIs. FINDINGS 31 672 firearm-related deaths occurred in 2010 in the USA (10·1 per 100 000 people; mean state-specific count 631·5 [SD 629·1]). Of 25 firearm laws, nine were associated with reduced firearm mortality, nine were associated with increased firearm mortality, and seven had an inconclusive association. After adjustment for relevant covariates, the three state laws most strongly associated with reduced overall firearm mortality were universal background checks for firearm purchase (multivariable IRR 0·39 [95% CI 0·23-0·67]; p=0·001), ammunition background checks (0·18 [0·09-0·36]; p<0·0001), and identification requirement for firearms (0·16 [0·09-0·29]; p<0·0001). Projected federal-level implementation of universal background checks for firearm purchase could reduce national firearm mortality from 10·35 to 4·46 deaths per 100 000 people, background checks for ammunition purchase could reduce it to 1·99 per 100 000, and firearm identification to 1·81 per 100 000. INTERPRETATION Very few of the existing state-specific firearm laws are associated with reduced firearm mortality, and this evidence underscores the importance of focusing on relevant and effective firearms legislation. Implementation of universal background checks for the purchase of firearms or ammunition, and firearm identification nationally could substantially reduce firearm mortality in the USA. FUNDING None.