2 resultados para Aksakov, I. S. (Ivan Sergeevich), 1823-1886

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Physiologic data display is essential to decision making in critical care. Current displays echo first-generation hemodynamic monitors dating to the 1970s and have not kept pace with new insights into physiology or the needs of clinicians who must make progressively more complex decisions about their patients. The effectiveness of any redesign must be tested before deployment. Tools that compare current displays with novel presentations of processed physiologic data are required. Regenerating conventional physiologic displays from archived physiologic data is an essential first step. OBJECTIVES: The purposes of the study were to (1) describe the SSSI (single sensor single indicator) paradigm that is currently used for physiologic signal displays, (2) identify and discuss possible extensions and enhancements of the SSSI paradigm, and (3) develop a general approach and a software prototype to construct such "extended SSSI displays" from raw data. RESULTS: We present Multi Wave Animator (MWA) framework-a set of open source MATLAB (MathWorks, Inc., Natick, MA, USA) scripts aimed to create dynamic visualizations (eg, video files in AVI format) of patient vital signs recorded from bedside (intensive care unit or operating room) monitors. Multi Wave Animator creates animations in which vital signs are displayed to mimic their appearance on current bedside monitors. The source code of MWA is freely available online together with a detailed tutorial and sample data sets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Methodological evaluation of the proteomic analysis of cardiovascular-tissue material has been performed with a special emphasis on establishing examinations that allow reliable quantitative analysis of silver-stained readouts. Reliability, reproducibility, robustness and linearity were addressed and clarified. In addition, several types of normalization procedures were evaluated and new approaches are proposed. It has been found that the silver-stained readout offers a convenient approach for quantitation if a linear range for gel loading is defined. In addition, a broad range of a 10-fold input (loading 20-200 microg per gel) fulfills the linearity criteria, although at the lowest input (20 microg) a portion of protein species will remain undetected. The method is reliable and reproducible within a range of 65-200 microg input. The normalization procedure using the sum of all spot intensities from a silver-stained 2D pattern has been shown to be less reliable than other approaches, namely, normalization through median or through involvement of interquartile range. A special refinement of the normalization through virtual segmentation of pattern, and calculation of normalization factor for each stratum provides highly satisfactory results. The presented results not only provide evidence for the usefulness of silver-stained gels for quantitative evaluation, but they are directly applicable to the research endeavor of monitoring alterations in cardiovascular pathophysiology.