63 resultados para Agreement error

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical manifestations of lactase (LCT) deficiency include intestinal and extra-intestinal symptoms. Lactose hydrogen breath test (H2-BT) is considered the gold standard to evaluate LCT deficiency (LD). Recently, the single-nucleotide polymorphism C/T(-13910) has been associated with LD. The objectives of the present study were to evaluate the agreement between genetic testing of LCT C/T(-13910) and lactose H2-BT, and the diagnostic value of extended symptom assessment. Of the 201 patients included in the study, 194 (139 females; mean age 38, range 17-79 years, and 55 males, mean age 38, range 18-68 years) patients with clinical suspicion of LD underwent a 3-4 h H2-BT and genetic testing for LCT C/T(-13910). Patients rated five intestinal and four extra-intestinal symptoms during the H2-BT and then at home for the following 48 h. Declaring H2-BT as the gold standard, the CC(-13910) genotype had a sensitivity of 97% and a specificity of 95% with a of 0.9 in diagnosing LCT deficiency. Patients with LD had more intense intestinal symptoms 4 h following the lactose challenge included in the H2-BT. We found no difference in the intensity of extra-intestinal symptoms between patients with and without LD. Symptom assessment yielded differences for intestinal symptoms abdominal pain, bloating, borborygmi and diarrhoea between 120 min and 4 h after oral lactose challenge. Extra-intestinal symptoms (dizziness, headache and myalgia) and extension of symptom assessment up to 48 h did not consistently show different results. In conclusion, genetic testing has an excellent agreement with the standard lactose H2-BT, and it may replace breath testing for the diagnosis of LD. Extended symptom scores and assessment of extra-intestinal symptoms have limited diagnostic value in the evaluation of LD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients can make contributions to the safety of chemotherapy administration but little is known about their motivations to participate in safety-enhancing strategies. The theory of planned behavior was applied to analyze attitudes, norms, behavioral control, and chemotherapy patients' intentions to participate in medical error prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical errors are a serious threat to chemotherapy patients. Patients can make contributions to safety but little is known about the acceptability of error-preventing behaviors and its predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extension of 3-D atmospheric data products back into the past is desirable for a wide range of applications. Historical upper-air data are important in this endeavour, particularly in the maritime regions of the tropics and the southern hemisphere, where observations are extremely sparse. Here we present newly digitized and re-evaluated early ship-based upper-air data from two cruises: (1) kite and registering balloon profiles from onboard the ship SMS Planet on a cruise from Europe around South Africa and across the Indian Ocean to the western Pacific in 1906/1907, and (2) ship-based radiosonde data from onboard the MS Schwabenland on a cruise from Europe across the Atlantic to Antarctica and back in 1938/1939. We describe the data and provide estimations of the errors. We compare the data with a recent reanalysis (the Twentieth Century Reanalysis Project, 20CR, Compo et al., 2011) that provides global 3-D data back to the 19th century based on an assimilation of surface pressure data only (plus monthly mean sea-surface temperatures). In cruise (1), the agreement is generally good, but large temperature differences appear during a period with a strong inversion. In cruise (2), after a subset of the data are corrected, close agreement between observations and 20CR is found for geopotential height (GPH) and temperature notwithstanding a likely cold bias of 20CR at the tropopause level. Results are considerably worse for relative humidity, which was reportedly inaccurately measured. Note that comparing 20CR, which has limited skill in the tropical regions, with measurements from ships in remote regions made under sometimes difficult conditions can be considered a worst case assessment. In view of that fact, the anomaly correlations for temperature of 0.3–0.6 in the lower troposphere in cruise (1) and of 0.5–0.7 for tropospheric temperature and GPH in cruise (2) are considered as promising results. Moreover, they are consistent with the error estimations. The results suggest room for further improvement of data products in remote regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine interobserver and intraobserver agreement for results of low-field magnetic resonance imaging (MRI) in dogs with and without disk-associated wobbler syndrome (DAWS). DESIGN: Validation study. ANIMALS: 21 dogs with and 23 dogs without clinical signs of DAWS. PROCEDURES: For each dog, MRI of the cervical vertebral column was performed. The MRI studies were presented in a randomized sequence to 4 board-certified radiologists blinded to clinical status. Observers assessed degree of disk degeneration, disk-associated and dorsal compression, alterations in intraspinal signal intensity (ISI), vertebral body abnormalities, and new bone formation and categorized each study as originating from a clinically affected or clinically normal dog. Interobserver agreement was calculated for 44 initial measurements for each observer. Intraobserver agreement was calculated for 11 replicate measurements for each observer. RESULTS: There was good interobserver agreement for ratings of disk degeneration and vertebral body abnormalities and moderate interobserver agreement for ratings of disk-associated compression, dorsal compression, alterations in ISI, new bone formation, and suspected clinical status. There was very good intraobserver agreement for ratings of disk degeneration, disk-associated compression, alterations in ISI, vertebral body abnormalities, and suspected clinical status. There was good intraobserver agreement for ratings of dorsal compression and new bone formation. Two of 21 clinically affected dogs were erroneously categorized as clinically normal, and 4 of 23 clinically normal dogs were erroneously categorized as clinically affected. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that variability exists among observers with regard to results of MRI in dogs with DAWS and that MRI could lead to false-positive and false-negative assessments.