6 resultados para Aesthetic evaluation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The aim of the study was to analyse the aesthetic evaluation of head photographs of treated individuals with clefts by laypeople and professionals and to investigate how certain cephalometric variables could be related to their rating. A set of five standardized head photos (frontal, both laterals, three-quater right and left) of 12 Caucasian patients with treated unilateral cleft lip and palate were presented to 12 adult laypeople, 12 orthodontists, and 12 maxillofacial surgeons. For each set of photos the judges had to answer four questions on a visual analogue scale (VAS). The answers were analysed for intra- and inter-panel level of agreement and correlations of assessments with certain cephalometric parameters were determined. There was a high level of agreement for all assessments of each panel of raters. However, laypeople were less satisfied with lip and nose aesthetics compared to professionals. The three groups were similarly satisfied with the aesthetics of the jaws and the face. The anterior position of the maxilla (SNA) influenced positively professionals' ratings of facial aesthetics. Orthodontists were negatively influenced when the vertical dimension of the face or the distance of the lower lip to E-plane were relatively increased. The latter was the only cephalometric parameter correlated with lower aesthetic scores obtained from laypeople. Professionals report greater satisfaction from the treatment outcome and evaluate cleft consequences with less severity than laypeople. According to cephalometric findings, the relative positions of the lips seem to dominate facial aesthetics' appreciation by laypeople, while specialists appear to focus on different features of the face.
Resumo:
This paper presents a neuroscientific study of aesthetic judgments on written texts. In an fMRI experiment participants read a number of proverbs without explicitly evaluating them. In a post-scan rating they rated each item for familiarity and beauty. These individual ratings were correlated with the functional data to investigate the neural correlates of implicit aesthetic judgments. We identified clusters in which BOLD activity was correlated with individual post-scan beauty ratings. This indicates that some spontaneous aesthetic evaluation takes place during reading, even if not required by the task. Positive correlations were found in the ventral striatum and in medial prefrontal cortex, likely reflecting the rewarding nature of sentences that are aesthetically pleasing. On the contrary, negative correlations were observed in the classic left frontotemporal reading network. Midline structures and bilateral temporo-parietal regions correlated positively with familiarity, suggesting a shift from the task-network towards the default network with increasing familiarity.
Resumo:
OBJECTIVES The aim of the study was to identify differences in the aesthetic evaluation of profile and frontal photographs of (1) patients treated for complete left-sided cleft lip and palate and (2) control patients by laypeople and professionals. MATERIALS, SUBJECTS, AND METHODS Left-side profile and frontal photographs of 20 adult patients treated for complete left-sided cleft lip and palate (10 men, 10 women, mean age: 20.5 years) and of 10 control patients with a class I occlusion (five men, five women, mean age: 22.1 years) were included in the study. The post-treatment photographs were evaluated by 15 adult laypeople, 14 orthodontists, and 10 maxillofacial surgeons. Each photograph was judged on a modified visual analogue scale (VA S, 0-10; 0 'very unattractive' to 10 'very attractive'). A four-level mixed model was fitted in which the VA S score was the dependent variable; cases, profession, view, and rater were independent variables. RESULTS Compared with laypersons, orthodontists gave higher VA S scores (+0.69, 95% confidence interval (CI) [0.53, 0.84]; P < 0.001), followed by surgeons (+0.21, 95% CI [0.03, 0.38], P = 0.02). Controls were given significantly higher scores than patients with clefts for profile and frontal photographs (+1.97, 95% CI [1.60; 2.35], P < 0.001). No significant difference was found between the scores for the frontal and lateral views (P = 0.46). CONCLUSIONS All the different rater panels were less satisfied with the facial aesthetics of patients with clefts compared with that of control patients. Further research should evaluate whether these findings correlate with patients' self-perception and to what extent it affects the patients' psychosocial well-being.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.