17 resultados para Activity concentration index

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

High ³⁷Ar activity concentration in soil gas is proposed as a key evidence for the detection of underground nuclear explosion by the Comprehensive Nuclear Test-Ban Treaty. However, such a detection is challenged by the natural background of ³⁷Ar in the subsurface, mainly due to Ca activation by cosmic rays. A better understanding and improved capability to predict ³⁷Ar activity concentration in the subsurface and its spatial and temporal variability is thus required. A numerical model integrating ³⁷Ar production and transport in the subsurface is developed, including variable soil water content and water infiltration at the surface. A parameterized equation for ³⁷Ar production in the first 15 m below the surface is studied, taking into account the major production reactions and the moderation effect of soil water content. Using sensitivity analysis and uncertainty quantification, a realistic and comprehensive probability distribution of natural ³⁷Ar activity concentrations in soil gas is proposed, including the effects of water infiltration. Site location and soil composition are identified as the parameters allowing for a most effective reduction of the possible range of ³⁷Ar activity concentrations. The influence of soil water content on ³⁷Ar production is shown to be negligible to first order, while ³⁷Ar activity concentration in soil gas and its temporal variability appear to be strongly influenced by transient water infiltration events. These results will be used as a basis for practical CTBTO concepts of operation during an OSI.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gatifloxacin penetrated well into cerebrospinal fluid (CSF) (49 +/- 11%), measured by comparison of AUC(CSF)/AUC(serum), and showed good bactericidal activity (leading to a decrease of 0.75 +/- 0.17 log10 cfu/mL/h) in the treatment of experimental meningitis in rabbits caused by a penicillin-resistant pneumococcal strain (MIC 4 mg/L). It was significantly more effective than the standard regimen, ceftriaxone with vancomycin, which led to a decrease of 0.53 +/- 0.17 log10 cfu/mL/h. The addition of cefepime to gatifloxacin slightly improved the killing rates (giving a decrease of 0.84 +/- 0.14 log10 cfu/mL/h). In vitro, synergy was demonstrated between cefepime and gatifloxacin by the chequerboard method (fractional inhibitory concentration index = 0.5) and by viable counts over 8 h.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM of this study was the assessment of the radiation exposure from preparation and application of (90)Y-Zevalin, the measurement of the dose rate at the patient, the exposure of family members as well as the determination of the activity concentration in urine of patients. METHODS: Overall data from 31 therapeutic administrations carried out in four institutions were evaluated. During preparation and application of (90)Y-Zevalin the finger exposures of radiochemists, technicians, and physicians were measured. The dose rate of the patient was measured immediately after radioimmunotherapy. In patients treated in a nuclear medicine therapy unit, urine was collected over a two day period and the corresponding activity was determined. Family members of outpatients were asked to wear a dosimeter over a seven day period. RESULTS: During the preparation we found a maximum skin dose of 6 mSv at the average, and during application of 3 mSv, respectively. After administration of (90)Y the dose rate was 0.4 +/- 0.1 microSv/h at 2 m distance. Urine measurements yielded a cumulated 24 h excretion of 3.9 +/- 1.4% and 4.4 +/- 1.4% within 48 h, respectively, that is equivalent to 43 +/- 18 and 50 +/- 20 MBq of (90)Y, respectively. Family members received a radiation exposure of 40 +/- 14 microSv over seven days. CONCLUSION: During preparation and application of (90)Y-Zevalin appropriate radiation shielding is necessary. For family members as well as nursing staff no additional special radiation protection measures beyond those being common for other nuclear medicine procedures are necessary.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The bactericidal activities of monotherapy with trovafloxacin (-0.37 +/- 0.15 Delta log(10) CFU/ml. h), vancomycin (-0.32 +/- 0.12 Delta log(10) CFU/ml. h), and ceftriaxone (-0.36 +/- 0.19 Delta log(10) CFU/ml. h) for the treatment of experimental meningitis in rabbits due to a clinical penicillin-resistant pneumococcal strain (MIC, 4 mg/liter) were similar. The combination of ceftriaxone with trovafloxacin considerably improved the killing rates (-0.67 +/- 0.16 Delta log(10) CFU/ml. h) and was slightly superior to ceftriaxone with vancomycin (killing rate, -0.53 +/- 0. 22 Delta log(10) CFU/ml. h), the regimen most commonly used in clinical practice. In vitro, synergy was demonstrated between ceftriaxone and trovafloxacin by the checkerboard method (fractional inhibitory concentration index, 0.5) and by time-killing assays over 8 h.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tree-ring series were collected for radiocarbon analyses from the vicinity of Paks nuclear power plant (NPP) and a background area (Dunaföldvár) for a 10-yr period (2000–2009). Samples of holocellulose were prepared from the wood and converted to graphite for accelerator mass spectrometry (AMS) 14C measurement using the MICADAS at ETH Zürich. The 14C concentration data from these tree rings was compared to the background tree rings for each year. The global decreasing trend of atmospheric 14C activity concentration was observed in the annual tree rings both in the background area and in the area of the NPP. As an average of the past 10 yr, the excess 14C emitted by the pressurized-water reactor (PWR) NPP to the atmosphere shows only a slight systematic excess (~6‰) 14C in the annual rings. The highest 14C excess was 13‰ (in 2006); however, years with the same 14C level as the background were quite frequent in the tree-ring series.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In 2005, two ice cores with lengths of 58.7 and 57.6 m respectively to bedrock were recovered from the Miaoergou flat-topped glacier (43 degrees 03 ' 19 '' N, 94 degrees 19 ' 21 '' E; 4512 m a.s.l.), eastern Tien Shan. Pb-210 dating of one of the ice cores (57.6 m) was performed, and an age of AD 1851 +/- 6 at a depth of 35.2 m w.e. was determined. For the period AD 1851-2005, a mean annual net accumulation of 229 +/- 7 mm w.e. a(-1) was calculated. At the nearby oasis city of Hami (similar to 80 km from the Miaoergou flat-topped glacier) the annual precipitation rate is 38 mm w.e. a(-1), hence glacial meltwater is a major water supply for local residents. The surface activity concentration of Pb-210(ex) was found to be similar to 400 mBq kg(-1), which is higher than observed at other continental sites such as Belukha, Russia, and Tsambagarav, Mongolia, which have surface activity concentrations of 280 mBq kg(-1). The Pb-210 dating agrees well with the chronological sequence deduced from the annual-layer counting resulting from the seasonalities of delta O-18 and trace metals for the period AD 1953-2005, and beta-activity horizons resulting from atmospheric nuclear testing during the period AD 1962-63. We conclude that Pb-210 analysis is a suitable method for obtaining a continuous dating of the Miaoergou ice core for similar to 160 years, which can also be applied to other ice cores recovered from the mountains of western China.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Terbium-149 is among the most interesting therapeutic nuclides for medical applications. It decays by emission of short-range α-particles (Eα = 3.967 MeV) with a half-life of 4.12 h. The goal of this study was to investigate the anticancer efficacy of a 149Tb-labeled DOTA-folate conjugate (cm09) using folate receptor (FR)-positive cancer cells in vitro and in tumor-bearing mice. 149Tb was produced at the ISOLDE facility at CERN. Radiolabeling of cm09 with purified 149Tb resulted in a specific activity of ~1.2 MBq/nmol. In vitro assays performed with 149Tb-cm09 revealed a reduced KB cell viability in a FR-specific and activity concentration-dependent manner. Tumor-bearing mice were injected with saline only (group A) or with 149Tb-cm09 (group B: 2.2 MBq; group C: 3.0 MBq). A significant tumor growth delay was found in treated animals resulting in an increased average survival time of mice which received 149Tb-cm09 (B: 30.5 d; C: 43 d) compared to untreated controls (A: 21 d). Analysis of blood parameters revealed no signs of acute toxicity to the kidneys or liver in treated mice over the time of investigation. These results demonstrated the potential of folate-based α-radionuclide therapy in tumor-bearing mice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The majority of histopathological classifications of primary chronic viral hepatitis and recurrence of HCV infection in liver transplants is based on the histological activity index (HAI) introduced by Knodell et al in 1981; however, correlation between HAI and clinical/laboratory data is poor. Therefore, the aim of this study was to present a modification of HAI (mHAI) adapted to distinct features of graft infection, and to evaluate its usefulness in the description of disease activity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to quantify the effects of isoflurane at approximately the minimum alveolar concentration (peri-MAC) on the temporal summation (TS) of reflex activity in ponies. TS was evoked by repeated electrical stimulations applied at 5 Hz for 2 s on the digital nerve of the left forelimb of seven ponies. Surface electromyographic activity was recorded from the deltoid and common digital extensor muscles. TS thresholds and amplitude of response to stimulations of increasing intensities were assessed during anaesthesia at 0.85, 0.95 and 1.05 times the individual MAC, and after anaesthesia in standing animals. Under isoflurane anaesthesia, TS thresholds increased significantly in a concentration-dependent fashion and at each isoflurane MAC, the responses increased significantly for increasing stimulation intensities. A concentration-dependent depression of evoked reflexes with a reduction in the slopes of the stimulus-response function was observed for both muscles. The results demonstrated that with this model it is possible to describe and quantify the effects of anaesthetics on spinal sensory-motor processing in ponies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Melatonin has previously been suggested to affect hemostatic function but studies on the issue are scant. We hypothesized that, in humans, oral administration of melatonin is associated with decreased plasma levels of procoagulant hemostatic measures compared with placebo medication and that plasma melatonin concentration shows an inverse association with procoagulant measures. Forty-six healthy men (mean age 25 +/- 4 yr) were randomized, single-blinded, to either 3 mg of oral melatonin (n = 25) or placebo medication (n = 21). One hour thereafter, levels of melatonin, fibrinogen, and D-dimer as well as activities of coagulation factor VII (FVII:C) and VIII (FVIII:C) were measured in plasma. Multivariate analysis of covariance and regression analysis controlled for age, body mass index, mean arterial blood pressure, heart rate, and norepinephrine plasma level. Subjects on melatonin had significantly lower mean levels of FVIII:C (81%, 95% CI 71-92 versus 103%, 95% CI 90-119; P = 0.018) and of fibrinogen (1.92 g/L, 95% CI 1.76-2.08 versus 2.26 g/L, 95% CI 2.09-2.43; P = 0.007) than those on placebo explaining 14 and 17% of the respective variance. In all subjects, increased plasma melatonin concentration independently predicted lower levels of FVIII:C (P = 0.037) and fibrinogen (P = 0.022) explaining 9 and 11% of the respective variance. Melatonin medication and plasma concentration were not significantly associated with FVII:C and D-dimer levels. A single dose of oral melatonin was associated with lower plasma levels of procoagulant factors 60 min later. There might be a dose-response relationship between the plasma concentration of melatonin and coagulation activity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND The correlation between noninvasive markers with endoscopic activity according to the modified Baron Index in patients with ulcerative colitis (UC) is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), hemoglobin, platelets, blood leukocytes, and the Lichtiger Index (clinical score). METHODS UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Samples from feces and blood were analyzed in UC patients and controls. RESULTS We enrolled 228 UC patients and 52 healthy controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), platelets (r = 0.488), blood leukocytes (r = 0.401), and hemoglobin (r = -0.388). FC was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 16 [10-30] μg/g; grade 1, 35 [25-48] μg/g; grade 2, 102 [44-159] μg/g; grade 3, 235 [176-319] μg/g; grade 4, 611 [406-868] μg/g; P < 0.001 for discriminating the different grades). FC with a cutoff of 57 μg/g had a sensitivity of 91% and a specificity of 90% to detect endoscopically active disease (modified Baron Index ≥ 2). CONCLUSIONS FC correlated better with endoscopic disease activity than clinical activity, CRP, platelets, hemoglobin, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.