6 resultados para Active material
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
A pi-conjugated tetrathiafulvalene-fused perylenediimide (TTF-PDI) molecular dyad is successfully used as a solution-processed active material for light sensitive ambipolar field-effect transistors with balanced hole and electron mobilities. The photo-response of the TTF-PDI dyad resembles its absorption profile. Wavelength-dependent photoconductivity measurements reveal an important photo-response at an energy corresponding to a PDI-localized electronic pi-pi* transition and also a more moderate effect due to an intramolecular charge transfer from the HOMO localized on the TTF unit to the LUMO localized on the PDI moiety. This work clearly elucidates the interplay between intra- and intermolecular electronic processes in organic devices.
Resumo:
AIM: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. MATERIAL AND METHODS: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). RESULTS: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). CONCLUSION: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with active Crohn's disease alters small-bowel motility in distant, non-affected segments. The motility patterns revealed reduced contraction-wave frequencies, amplitudes, and decreased luminal occlusion rates. Thus evaluation of these characteristics potentially helps to differentiate between chronic and active Crohn's disease.
Resumo:
AIM To investigate risk factors for the loss of multi-rooted teeth (MRT) in subjects treated for periodontitis and enrolled in supportive periodontal therapy (SPT). MATERIAL AND METHODS A total of 172 subjects were examined before (T0) and after active periodontal therapy (APT)(T1) and following a mean of 11.5 ± 5.2 (SD) years of SPT (T2). The association of risk factors with loss of MRT was analysed with multilevel logistic regression. The tooth was the unit of analysis. RESULTS Furcation involvement (FI) = 1 before APT was not a risk factor for tooth loss compared with FI = 0 (p = 0.37). Between T0 and T2, MRT with FI = 2 (OR: 2.92, 95% CI: 1.68, 5.06, p = 0.0001) and FI = 3 (OR: 6.85, 95% CI: 3.40, 13.83, p < 0.0001) were at a significantly higher risk to be lost compared with those with FI = 0. During SPT, smokers lost significantly more MRT compared with non-smokers (OR: 2.37, 95% CI: 1.05, 5.35, p = 0.04). Non-smoking and compliant subjects with FI = 0/1 at T1 lost significantly less MRT during SPT compared with non-compliant smokers with FI = 2 (OR: 10.11, 95% CI: 2.91, 35.11, p < 0.0001) and FI = 3 (OR: 17.18, 95% CI: 4.98, 59.28, p < 0.0001) respectively. CONCLUSIONS FI = 1 was not a risk factor for tooth loss compared with FI = 0. FI = 2/3, smoking and lack of compliance with regular SPT represented risk factors for the loss of MRT in subjects treated for periodontitis.
Resumo:
OBJECTIVES To assess the association between presence of periodontal pathogens and recurrence of disease in patients with aggressive periodontitis (AgP) after active periodontal therapy (APT) and further influencing factors. MATERIAL & METHODS Microbiological samples were taken from 73 patients with AgP 5-17 years after APT at 292 sites (deepest site per quadrant). Real-time polymerase chain reactions were used to detect the periodontal pathogens Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia and Treponema denticola. Uni- and multivariate analyses evaluated the associations between pathogens and recurrence of disease, smoking and adjunctive antibiotic therapy. RESULTS At re-examination A. actinomycetemcomitans could be detected in six patients (8.2%), P. gingivalis in 24 (32.9%), T. forsythia in 31 (42.5%) and T. denticola in 35 (48.0%). Increased levels of T. forsythia and T. denticola at re-examination were significantly associated with recurrence of disease in multivariate analyses (OR: 12.72, p < 0.001; OR 5.55, p = 0.002 respectively). Furthermore, high counts of T. denticola were found in patients with increased percentage of sites with clinical attachment levels (CAL) ≥ 6 mm compared to those with low counts (13.8% versus 3.2%, p = 0.005). CONCLUSION In patients with recurrence of disease T. forsythia and T. denticola were detected more frequently and in higher counts. Furthermore, T. denticola was found more frequently in patients with increased CAL.
Resumo:
Here we report the first study on the electrochemical energy storage application of a surface-immobilized ruthenium complex multilayer thin film with anion storage capability. We employed a novel dinuclear ruthenium complex with tetrapodal anchoring groups to build well-ordered redox-active multilayer coatings on an indium tin oxide (ITO) surface using a layer-by-layer self-assembly process. Cyclic voltammetry (CV), UV-Visible (UV-Vis) and Raman spectroscopy showed a linear increase of peak current, absorbance and Raman intensities, respectively with the number of layers. These results indicate the formation of well-ordered multilayers of the ruthenium complex on ITO, which is further supported by the X-ray photoelectron spectroscopy analysis. The thickness of the layers can be controlled with nanometer precision. In particular, the thickest layer studied (65 molecular layers and approx. 120 nm thick) demonstrated fast electrochemical oxidation/reduction, indicating a very low attenuation of the charge transfer within the multilayer. In situ-UV-Vis and resonance Raman spectroscopy results demonstrated the reversible electrochromic/redox behavior of the ruthenium complex multilayered films on ITO with respect to the electrode potential, which is an ideal prerequisite for e.g. smart electrochemical energy storage applications. Galvanostatic charge–discharge experiments demonstrated a pseudocapacitor behavior of the multilayer film with a good specific capacitance of 92.2 F g−1 at a current density of 10 μA cm−2 and an excellent cycling stability. As demonstrated in our prototypical experiments, the fine control of physicochemical properties at nanometer scale, relatively good stability of layers under ambient conditions makes the multilayer coatings of this type an excellent material for e.g. electrochemical energy storage, as interlayers in inverted bulk heterojunction solar cell applications and as functional components in molecular electronics applications.
Resumo:
We are currently setting up a facility for low-background gamma-ray spectrometry based on a HPGe detector. It is dedicated to material screening for the XENON and DARWIN dark matter projects as well as to the characterization of meteorites. The detector will be installed in a medium depth (∼620 m.w.e.) underground laboratory in Switzerland with several layers of shielding and an active muon-veto. The GeMSE facility will be operational by fall 2015 with an expected background rate of ∼250 counts/day (100-2700 keV).