9 resultados para Active magnetic bearings (AMB)
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
For atmospheric CO2 reconstructions using ice cores, the technique to release the trapped air from the ice samples is essential for the precision and accuracy of the measurements. We present here a new dry extraction technique in combination with a new gas analytical system that together show significant improvements with respect to current systems. Ice samples (3–15 g) are pulverised using a novel centrifugal ice microtome (CIM) by shaving the ice in a cooled vacuum chamber (−27 °C) in which no friction occurs due to the use of magnetic bearings. Both, the shaving principle of the CIM and the use of magnetic bearings have not been applied so far in this field. Shaving the ice samples produces finer ice powder and releases a minimum of 90% of the trapped air compared to 50%–70% when needle crushing is employed. In addition, the friction-free motion with an optimized design to reduce contaminations of the inner surfaces of the device result in a reduced system offset of about 2.0 ppmv compared to 4.9 ppmv. The gas analytical part shows a higher precision than the corresponding part of our previous system by a factor of two, and all processes except the loading and cleaning of the CIM now run automatically. Compared to our previous system, the complete system shows a 3 times better measurement reproducibility of about 1.1 ppmv (1 σ) which is similar to the best reproducibility of other systems applied in this field. With this high reproducibility, no replicate measurements are required anymore for most future measurement campaigns resulting in a possible output of 12–20 measurements per day compared to a maximum of 6 with other systems.
Resumo:
Three-dimensional oxalate-based {[Ru(bpy)3][Cu2xNi2(1-x)(ox)3]}n (0≤ x ≤ 1, ox = C2O42-, bpy = 2,2‘bipyridine) were synthesized. The structure was determined for x = 1 by X-ray diffraction on single crystal. The compound crystallizes in the cubic space group P4132. It shows a three-dimensional 10-gon 3-connected (10,3) anionic network where copper(II) has an unusual tris(bischelated) environment. X-ray powder diffraction patterns and their Rietveld refinement show that all the compounds along the series are isostructural and single-phased. According to X-ray absorption spectroscopy, copper(II) and nickel(II) have an octahedral environment, respectively elongated and trigonally distorted. As shown by natural circular dichroism, the optically active forms of {[Ru(bpy)3][CuxNi2(1-x)(ox)3]}n are obtained starting from resolved Δ- or Λ-[Ru(bpy)3]2+. The Curie−Weiss temperatures range between −55 (x = 1) and −150 K (x = 0). The antiferromagnetic exchange interaction thus decreases when the copper contents increases in agreement with the crystallographic structure of the compounds and the electronic structure of the metal ions. At low temperature, the compounds exhibit complex long-range ordered magnetic behavior.
Resumo:
Adrenocortical tumors are rare in children and present with variable signs depending on the type of hormone excess. We herein describe the unusual presentation of a child with adrenocortical tumor and introduce the concept of in vitro chemosensitivity testing. CASE REPORT: A 10.5-year-old girl presented with hypertrichosis/hirsutism and weight loss. The weight loss and behavioral problems, associated with halted puberty and growth, led to the initial diagnosis of anorexia nervosa. However, subsequent weight gain but persisting arrest in growth and puberty and the appearance of central fat distribution prompted further evaluation. RESULTS AND FOLLOW-UP: 24h-urine free cortisol was elevated. Morning plasma ACTH was undetectable, while cortisol was elevated and circadian rhythmicity was absent. Thus a hormonally active adrenal cortical tumor (ACT) was suspected. On magnetic resonance imaging (MRI) a unilateral, encapsulated tumor was found which was subsequently removed surgically. Tissue was investigated histologically and for chemosensitivity in primary cell cultures. Although there were some risk factors for malignancy, the tumor was found to be a typical adenoma. Despite this histology, tumor cells survived in culture and were sensitive to cisplatin in combination with gemcitabine or paclitaxel. At surgery, the patient was started on hydrocortisone replacement which was unsuccessfully tapered over 3 months. Full recovery of the hypothalamus-pituitary-adrenal axis occurred only after 3 years. CONCLUSIONS: The diagnosis of a hormonally active adrenocortical tumor is often delayed because of atypical presentation. Cortisol replacement following unilateral tumor excision is mandatory and may be required for months or years. Individualized chemosensitivity studies carried out on primary cultures established from the tumor tissue itself may provide a tool in evaluating the effectiveness of chemotherapeutic drugs in the event that the adrenocortical tumor may prove to be carcinoma.
Resumo:
Automatic scan planning for magnetic resonance imaging of the knee aims at defining an oriented bounding box around the knee joint from sparse scout images in order to choose the optimal field of view for the diagnostic images and limit acquisition time. We propose a fast and fully automatic method to perform this task based on the standard clinical scout imaging protocol. The method is based on sequential Chamfer matching of 2D scout feature images with a three-dimensional mean model of femur and tibia. Subsequently, the joint plane separating femur and tibia, which contains both menisci, can be automatically detected using an information-augmented active shape model on the diagnostic images. This can assist the clinicians in quickly defining slices with standardized and reproducible orientation, thus increasing diagnostic accuracy and also comparability of serial examinations. The method has been evaluated on 42 knee MR images. It has the potential to be incorporated into existing systems because it does not change the current acquisition protocol.
Resumo:
The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety
Resumo:
A 29-year-old woman with a long-lasting history of oligoamenorrhea, fell pregnant shortly after being diagnosed with acromegaly. LABORATORY TESTS AND IMAGING: A high IGF-1 concentration and an oral glucose tolerance test confirmed the diagnosis. Cranial magnetic resonance imaging demonstrated a macroadenoma of the pituitary with suprasellar extension and compression of the optic chiasm leading to incomplete hemianopsia.
Resumo:
OBJECTIVES: To study the validity of both rheumatological and orthodontic examinations and ultrasound (US) as screening methods for early diagnosis of TMJ arthritis against the gold standard MRI. METHODS: Thirty consecutive juvenile idiopathic arthritis (JIA) patients were included in this pilot study. Rheumatological and orthodontic examinations as well as US were performed within 1 month of the MRI in a blinded fashion. Joint effusion and/or increased contrast enhancement of synovium or bone were considered signs of active arthritis on MRI. RESULTS: A total of 19/30 (63%) patients and 33/60 (55%) joints had signs of TMJ involvement on MRI. This was associated with condylar deformity in 9/19 (47%) patients and 15/33 (45%) joints. Rheumatological, orthodontic and US examinations correctly diagnosed 11 (58%), 9 (47%) and 6 (33%) patients, respectively, with active TMJ arthritis, but misdiagnosed 8 (42%), 10 (53%) and 12 (67%) patients, respectively, as having no signs of inflammation. The best predictor for active arthritis on MRI was a reduced maximum mouth opening. CONCLUSION: None of the methods tested was able to reliably predict the presence or absence of MRI-proven inflammation in the TMJ in our cohort of JIA patients. US was the least useful of all methods tested to exclude active TMJ arthritis.
Resumo:
AIM: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. MATERIAL AND METHODS: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). RESULTS: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). CONCLUSION: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with active Crohn's disease alters small-bowel motility in distant, non-affected segments. The motility patterns revealed reduced contraction-wave frequencies, amplitudes, and decreased luminal occlusion rates. Thus evaluation of these characteristics potentially helps to differentiate between chronic and active Crohn's disease.
Resumo:
Purpose: Proper delineation of ocular anatomy in 3D imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic Resonance Imaging (MRI) is nowadays utilized in clinical practice for the diagnosis confirmation and treatment planning of retinoblastoma in infants, where it serves as a source of information, complementary to the Fundus or Ultrasound imaging. Here we present a framework to fully automatically segment the eye anatomy in the MRI based on 3D Active Shape Models (ASM), we validate the results and present a proof of concept to automatically segment pathological eyes. Material and Methods: Manual and automatic segmentation were performed on 24 images of healthy children eyes (3.29±2.15 years). Imaging was performed using a 3T MRI scanner. The ASM comprises the lens, the vitreous humor, the sclera and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens and the optic nerve, then aligning the model and fitting it to the patient. We validated our segmentation method using a leave-one-out cross validation. The segmentation results were evaluated by measuring the overlap using the Dice Similarity Coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90±2.12% for the sclera and the cornea, 94.72±1.89% for the vitreous humor and 85.16±4.91% for the lens. The mean distance error was 0.26±0.09mm. The entire process took 14s on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor and the lens using MRI. We additionally present a proof of concept for fully automatically segmenting pathological eyes. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.