3 resultados para Acoustic wave refraction

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Cardiac shock wave therapy (CSWT) delivered to the myocardium increases capillary density and regional myocardial blood flow in animal experiments. In addition, nonenzymatic nitric oxide production and the upregulation of vascular growth factor's mRNA by CSWT have been described. The aim of the study was therefore to test its potential to relieve symptoms in patients with chronic stable angina pectoris. Methods: Twenty-one patients (mean age 68.2 ± 8.3 years, 19 males) with chronic refractory angina pectoris and evidence of inducible myocardial ischemia during MIBI-SPECT imaging, were randomized into a treatment (n = 11) and a placebo arm (n = 10). The region of exercise-induced ischemia was treated with echocardiographic guidance during nine sessions over a period of 3 months. One session of CSWT consisted of 200 shots/spot (9--12 spots/session) with an energy intensity of 0.09 mJ/mm2. In the control group acoustic simulation was performed without energy application. Medication was kept unchanged during the whole treatment period. Results: In the treatment group, symptoms improved in 9/11 patients, and the ischemic threshold, determined by cardiopulmonary exercise stress testing, increased from 80 ± 28 to 95 ± 28 W (P= 0.036). In the placebo arm, only 2/10 patients reported an improvement and the ischemic threshold remained unchanged (98 ± 23 to 107 ± 23 W; P= 0.141). The items “physical functioning” (P= 0.043), “general health perception” (P= 0.046), and “vitality” (P= 0.035) of the SF-36 questionnaire significantly improved in the treatment arm, whereas in the placebo arm, no significant change was noted. Neither arrhythmias, troponin rise nor complications were observed during treatment. Conclusions: This placebo controlled trial shows a significant improvement in symptoms, quality of life parameters and ischemic threshold during exercise in patients with chronic refractory angina pectoris treated with CSWT. Thus, CSWT represents a new option for the treatment of patients with refractory AP.