63 resultados para Absorbed dose
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE: The aim of this study was to evaluate the feasibility of applying a previously described dose strategy based on (99m)Tc-pertechnetate thyroid uptake under thyrotropin suppression (TcTU(s)) to radioiodine therapy for unifocal thyroid autonomy. METHODS: A total of 425 consecutive patients (302 females, 123 males; age 63.1+/-10.3 years) with unifocal thyroid autonomy were treated at three different centres with (131)I, using Marinelli's formula for calculation of three different absorbed dose schedules: 100-300 Gy to the total thyroid volume according to the pre-treatment TcTU(s) (n=146), 300 Gy to the nodule volume (n=137) and 400 Gy to the nodule volume (n=142). RESULTS: Successful elimination of functional thyroid autonomy with either euthyroidism or hypothyroidism occurred at a mean of 12 months after radioiodine therapy in 94.5% of patients receiving 100-300 Gy to the thyroid volume, in 89.8% of patients receiving 300 Gy to the nodule volume and in 94.4% receiving 400 Gy to the nodule volume. Reduction in thyroid volume was highest for the 100-300 Gy per thyroid and 400 Gy per nodule strategies (36+/-19% and 38+/-20%, respectively) and significantly lower for the 300 Gy per nodule strategy (28+/-16%; p<0.01). CONCLUSION: A dose strategy based on the TcTU(s) can be used independently of the scintigraphic pattern of functional autonomous tissue in the thyroid.
Resumo:
AIM: Peptide receptor radionuclide therapy using the somatostatin analogue [(177)Lu-DOTA(0),Tyr(3)]octreotate is a convincing treatment modality for metastasized neuroendocrine tumors. Therapeutic doses are administered in 4 cycles with 6-10 week intervals. A high somatostatin receptor density on tumor cells is a prerequisite at every administration to enable effective therapy. In this study, the density of the somatostatin receptor subtype 2 (sst2) was investigated in the rat CA20948 pancreatic tumor model after low dose [(177)Lu-DOTA(0), Tyr(3)]octreotate administration resulting in approximately 20 Gy tumor radiation absorbed dose, whereas 60 Gy is needed to induce complete tumor regression in these and the majority of tumors. METHODS: Sixteen days after inoculation of the CA20948 tumor, male Lewis rats were injected with 185 MBq [(177)Lu-DOTA(0),Tyr(3)]octreotate to initiate a decline in tumor size. Approximately 40 days after injection, tumors re-grew progressively after initial response. Quantification of sst2 expression was performed using in vitro autoradiography on frozen sections of three groups: control (not-treated) tumors, tumors in regression and tumors in re-growth. Histology and proliferation were determined using HE- and anti-Ki-67-staining. RESULTS: The sst2 expression on CA20948 tumor cells decreased significantly after therapy to 5% of control level. However, tumors escaping from therapy showed an up-regulated sst2 level of 2-5 times higher sst2 density compared to control tumors. CONCLUSION: After a suboptimal therapeutic dose of [(177)Lu-DOTA(0),Tyr(3)]octreotate, escape of tumors is likely to occur. Since these cells show an up-regulated sst2 receptor density, a next therapeutic administration of radiolabelled sst2 analogue can be expected to be highly effective.
Resumo:
NCX-1000 (2(acetyloxy) benzoic acid-3(nitrooxymethyl)phenyl ester) is an nitric oxide (NO)-releasing derivative of ursodeoxycholic acid (UDCA), which showed selective vasodilatory effect on intrahepatic circulation in animal models of cirrhosis. This study was aimed at testing the efficacy and tolerability of this compound in patients with cirrhosis and portal hypertension.
Resumo:
The objective of our study was to compare the performance of low-dose linear slit digital radiography (DR) with computed radiography (CR) for the detection of trauma sequelae in the chest including rib fractures, pneumothorax, and lung contusion.
Resumo:
The primary objective was to determine the efficacy of a newly designed preoperative chemotherapy regimen in an attempt to improve the cure rate of children with high-risk hepatoblastoma.
Resumo:
Volumetric data at micrometer level resolution can be acquired within a few minutes using synchrotron-radiation-based tomographic microscopy. The field of view along the rotation axis of the sample can easily be increased by stacking several tomograms, allowing the investigation of long and thin objects at high resolution. On the contrary, an extension of the field of view in the perpendicular direction is non-trivial. This paper presents an acquisition protocol which increases the field of view of the tomographic dataset perpendicular to its rotation axis. The acquisition protocol can be tuned as a function of the reconstruction quality and scanning time. Since the scanning time is proportional to the radiation dose imparted to the sample, this method can be used to increase the field of view of tomographic microscopy instruments while optimizing the radiation dose for radiation-sensitive samples and keeping the quality of the tomographic dataset on the required level. This approach, dubbed wide-field synchrotron radiation tomographic microscopy, can increase the lateral field of view up to five times. The method has been successfully applied for the three-dimensional imaging of entire rat lung acini with a diameter of 4.1 mm at a voxel size of 1.48 microm.
Resumo:
Iron-platinum nanoparticles embedded in a poly(methacrylic acid) (PMA) polymer shell and fluorescently labeled with the dye ATTO 590 (FePt-PMA-ATTO-2%) are investigated in terms of their intracellular localization in lung cells and potential to induce a proinflammatory response dependent on concentration and incubation time. A gold core coated with the same polymer shell (Au-PMA-ATTO-2%) is also included. Using laser scanning and electron microscopy techniques, it is shown that the FePt-PMA-ATTO-2% particles penetrate all three types of cell investigated but to a higher extent in macrophages and dendritic cells than epithelial cells. In both cell types of the defense system but not in epithelial cells, a particle-dose-dependent increase of the cytokine tumor necrosis factor alpha (TNFalpha) is found. By comparing the different nanoparticles and the mere polymer shell, it is shown that the cores combined with the shells are responsible for the induction of proinflammatory effects and not the shells alone. It is concluded that the uptake behavior and the proinflammatory response upon particle exposure are dependent on the time, cell type, and cell culture.
Resumo:
to report acute and late toxicity in prostate cancer patients treated by high-dose intensity-modulated radiation therapy (IMRT) with daily image-guidance.
Resumo:
To describe biochemical relapse-free survival (BRFS) and late toxicity after combined high-dose rate brachytherapy (HDR-B) and intensity-modulated radiation therapy (IMRT) in intermediate- and high-risk prostate cancer patients.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation for 4 and 6 MeV electron beams of Varian linear accelerators.
Resumo:
Protective patient equipment for CT examinations is not routinely provided. The aim of this study was to determine whether, and if so what, specific protective equipment is beneficial during CT scans. The absorbed organ doses and the effective doses for thorax, abdomen/pelvis and brain CT investigation with and without the use of protective patient equipment have been determined and compared. All measurements were carried out on modern multislice CT scanner using an anthropomorphic phantom and thermoluminescence dosemeters. The measurements show that protective equipment reduces the dose within the scattered beam area. The highest organ dose reduction was found in organs that protrude from the trunk like the testes or the female breasts that can largely be covered by the protective equipment. The most reduction of the effective dose was found in the male abdomen/pelvis examination (0.32 mSv), followed by the brain (0.11 mSv) and the thorax (0.06 mSv). It is concluded that the use of protective equipment can reduce the applied dose to the patient.
Resumo:
Combined-modality treatment consisting of four to six cycles of chemotherapy followed by involved-field radiotherapy (IFRT) is the standard of care for patients with early unfavorable Hodgkin's lymphoma (HL). It is unclear whether treatment results can be improved with more intensive chemotherapy and which radiation dose needs to be applied.
Resumo:
Treatment strategies for relapsed/refractory AML are limited and disappointing. Recently, high-dose melphalan (HDM) chemotherapy and autologous hematopoietic SCT (HSCT) has been proposed for AML re-induction. We investigated the impact of HDM remission induction in highly advanced relapsed/refractory AML patients planned for allogeneic HSCT. A total of 23 patients with relapsed/refractory AML were prospectively scheduled for HDM with or without stem cell support followed by myeloablative allogeneic HSCT. Patients included nine individuals with a history of previous HSCT (seven allogeneic, two autologous). A total of 18 patients (78%) achieved a leukemia-free state and an additional four had substantial reduction of the initial leukemia burden warranting treatment continuation. There were no differences between patients with or without immediate stem cell support regarding mucositis or other organ toxicity. A total of 20 patients proceeded to myeloablative allogeneic HSCT. Outcome of allogeneic HSCT was poor: 11 patients (55%) relapsed, 7 patients (35%) died from TRM and only 2 patients (10%) were alive at the last follow-up. Our study shows that HDM is effective in inducing a leukemia-free state in patients with highly advanced relapsed/refractory AML. Leukemia burden reduction with HDM, however, did not translate into improved OS.
Resumo:
Computed tomography based navigation for endoscopic sinus surgery is inflationary used despite of major public concern about iatrogenic radiation induced cancer risk. Studies on dose reduction for CAS-CT are almost nonexistent. We validate the use of radiation dose reduced CAS-CT for clinically applied surface registration.