18 resultados para 730306 Evaluation of health outcomes

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate a protocol for a population-based programme targeting the prevention of rheumatic heart disease (RHD) progression by early echocardiographic diagnosis of valvular lesions and timely implementation of secondary prevention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Conventional factors do not fully explain the distribution of cardiovascular outcomes. Biomarkers are known to participate in well-established pathways associated with cardiovascular disease, and may therefore provide further information over and above conventional risk factors. This study sought to determine whether individual and/or combined assessment of 9 biomarkers improved discrimination, calibration and reclassification of cardiovascular mortality. METHODS 3267 patients (2283 men), aged 18-95 years, at intermediate-to-high-risk of cardiovascular disease were followed in this prospective cohort study. Conventional risk factors and biomarkers were included based on forward and backward Cox proportional stepwise selection models. RESULTS During 10-years of follow-up, 546 fatal cardiovascular events occurred. Four biomarkers (interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D) were retained during stepwise selection procedures for subsequent analyses. Simultaneous inclusion of these biomarkers significantly improved discrimination as measured by the C-index (0.78, P = 0.0001), and integrated discrimination improvement (0.0219, P<0.0001). Collectively, these biomarkers improved net reclassification for cardiovascular death by 10.6% (P<0.0001) when added to the conventional risk model. CONCLUSIONS In terms of adverse cardiovascular prognosis, a biomarker panel consisting of interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D offered significant incremental value beyond that conveyed by simple conventional risk factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Posterior lumbar fusion is a frequently performed procedure in spinal surgery. High percentages of good and excellent results are indicated by physicians. On the other hand patient-based outcomes are reported. Little is known about the correlations of these two assessment types. We aimed at their comparison. The analysis included 1013 patients with degenerative spinal disease or spondylolisthesis from an international spine registry, treated with posterior lumbar fusion. All patients were pre/postop assessed by physician-based McNab criteria (‘excellent’, ‘good’, ‘fair’, ‘poor’). Of these patients, 210 (mean age 61 years; 57% females) were in addition assessed by patient-based Oswestry Disability Index (ODI). The remaining 803 patients (mean age 59 years; 56% females) were assessed by patient-based Core Outcome Measure Index (COMI), including Visual Analogue Scale (VAS) for back and leg pain as well as verbal self-rating (‘helped a lot’, ‘helped’, ‘helped only little’, ‘didn’t help’, ‘made things worse’). McNab criteria were compared to the Minimal Clinically Important Difference (MCID) in ODI (12.8), in VAS back (1.2) and leg pain (1.6). We investigated the correlations between McNab criteria and these patient-based outcomes. In the ‘excellent’ group as rated by physicians, the proposed MCID was reached in 83% of patients for ODI, in 69% for VAS back and in 83% for VAS leg pain. All patients said the treatment had ‘helped’ or ‘helped a lot’. In the ‘good’ group 56% (ODI), 66% (back pain) and 86% (leg pain) reached the MCID. 96% of patients perceived the treatment as positive. In the ‘fair’ group 37% (ODI), 55% (back pain) and 63% (leg pain) reached the MCID. 49% had positive treatment considerations. The ‘poor’ group revealed 30% (ODI), 35% (back pain) and 44% (leg pain) of patients with reached MCID. Only 15% rated the treatment as positive. The Spearman correlation coefficients between McNab criteria on the one hand and ODI, back and leg pain as well as patients’ verbal self-rating on the other hand were 0.57, 0.37, 0.36 and 0.46 respectively. The comparison of physician and patient-based outcomes showed the highest correlations between McNab criteria and ODI, somewhat weaker correlations with patients’ self-rating and the weakest correlations with back and leg pain. Based on these findings, physicians’ evaluation of patient outcomes can be considered a valuable part of patient assessment, corresponding very well with patients’ perceptions of success or failure of spinal surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SPIRIT Women is the first interventional trial dedicated exclusively to women, focusing on symptoms at presentation, referral time to coronary intervention and the safety and performance of the XIENCE V stent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Although endoscopic scoring of the tracheal septum thickness is used as a diagnostic tool for evaluation of lower airway disease, its clinical relevance and reliability have never been critically assessed in the horse. OBJECTIVES: To investigate if septum thickness scores (STS) are reliable and serve as a clinically useful indicator of lower airway disease status and/or inflammation. METHODS: The variance of STS attributable to the horse, observer and changes over time was determined. The distribution of STS in a population of clinically normal horses and correlations of STS with age, gender, as well as mucus accumulation and cell differentials of tracheobronchial secretions and bronchoalveolar lavage fluid were investigated. Effects of altered pulmonary ventilation, induced by different drugs, on STS were assessed. Finally, STS of horses affected with recurrent airway obstruction (RAO) were compared to those of clinically normal horses. RESULTS: Recorded STS showed excellent intra- and satisfactory interobserver agreement Established clinical, endoscopic and cytological measures of lower airway inflammation, i.e. mucus accumulation scores and airway neutrophilia, did not correlate with STS. In horses age > or = 10 years, septum scores were significantly higher (P = 0.022) than in younger horses. Septum thickness scores did not differ significantly between clinically normal and RAO-affected horses both in exacerbation and in remission. Horses with markedly increased breathing effort (i.e. with metacholine- or lobeline hydrochloride-challenge), often differed markedly (up to 1.9 scores), but the average of end-inspiratory and end-expiratory STS did not differ from baseline STS. CONCLUSIONS AND CLINICAL RELEVANCE: Endoscopic STS are a reproducible measure, but STS did not correlate with clinical, endoscopic and cytological findings indicative of RAO or inflammatory airway disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to clinically and histologically evaluate the healing of human intrabony defects treated with open flap surgery (OFD) and application of a new, resorbable, fully synthetic, unsintered, nanocrystalline, phase-pure hydroxyapatite (nano-HA). MATERIALS AND METHODS Six patients, each of them displaying very advanced intrabony defects around teeth scheduled for extraction due to advanced chronic periodontitis and further prosthodontic considerations, were included in the study. Following local anaesthesia, mucoperiosteal flaps were reflected; the granulation tissue was removed, and the roots were meticulously debrided by hand and ultrasonic instruments. A notch was placed at the most apical extent of the calculus present on the root surface or at the most apical part of the defect (if no calculus was present) in order to serve as a reference for the histological evaluation. Following defect fill with nano-HA, the flaps were sutured by means of mattress sutures to allow primary intention healing. At 7 months after regenerative surgery, the teeth were extracted together with some of their surrounding soft and hard tissues and processed for histological analysis. RESULTS The postoperative healing was uneventful in all cases. At 7 months following surgery, mean PPD reduction and mean CAL gain measured 4.0 ± 0.8 and 2.5 ± 0.8 mm, respectively. The histological analysis revealed a healing predominantly characterized by epithelial downgrowth. Limited formation of new cementum with inserting connective tissue fibers and bone regeneration occurred in three out of the six biopsies (i.e. 0-0.86 and 0-1.33 mm, respectively). Complete resorption of the nano-HA was found in four out of the six biopsies. A few remnants of the graft particles (either surrounded by newly formed mineralized tissue or encapsulated in connective tissue) were found in two out of the six biopsies. CONCLUSION Within their limits, the present results indicate that nano-HA has limited potential to promote periodontal regeneration in human intrabony defects. CLINICAL RELEVANCE The clinical outcomes obtained following surgery with OFD + nano-HA may not reflect true periodontal regeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IMPORTANCE This study addresses the value of patients' reported symptoms as markers of tumor recurrence after definitive therapy for head and neck squamous cell carcinoma. OBJECTIVE To evaluate the correlation between patients' symptoms and objective findings in the diagnosis of local and/or regional recurrences of head and neck squamous cell carcinomas in the first 2 years of follow-up. DESIGN Retrospective single-institution study of a prospectively collected database. SETTING Regional hospital. PARTICIPANTS We reviewed the clinical records of patients treated for oral cavity, oropharyngeal, laryngeal, and hypopharyngeal carcinomas between January 1, 2008, and December 31, 2009, with a minimum follow-up of 2 years. MAIN OUTCOMES AND MEASURES Correlation between symptoms and oncologic status (recurrence vs remission) in the posttreatment period. RESULTS Of the 101 patients included, 30 had recurrences. Pain, odynophagia, and dysphonia were independently correlated with recurrence (odds ratios, 16.07, 11.20, and 5.90, respectively; P < .001). New-onset symptoms had the best correlation with recurrences. Correlation was better between 6 to 12 and 18 to 21 months after therapy and in patients initially treated unimodally (P < .05). Primary stage and tumor site had no effect. CONCLUSIONS AND RELEVANCE The correlation between symptoms and oncologic status is low during substantial periods within the first 2 years of follow-up. New-onset symptoms, especially pain, odynophagia, or dysphonia, better correlate with tumor recurrence, especially in patients treated unimodally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Contour augmentation around early-placed implants (Type 2 placement) using autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) and a collagen barrier membrane has been documented to predictably provide esthetically satisfactory clinical outcomes. In addition, recent data from cone beam computed tomography studies have shown the augmented volume to be stable long-term. However, no human histologic data are available to document the tissue reactions to this bone augmentation procedure. METHODS Over an 8-year period, 12 biopsies were harvested 14 to 80 months after implant placement with simultaneous contour augmentation in 10 patients. The biopsies were subjected to histologic and histomorphometric analysis. RESULTS The biopsies consisted of 32.0% ± 9.6% DBBM particles and 40.6% ± 14.6% mature bone. 70.3% ± 14.5% of the DBBM particle surfaces were covered with bone. On the remaining surface, multinucleated giant cells with varying intensity of tartrate-resistant acid phosphatase staining were regularly present. No signs of inflammation were visible, and no tendency toward a decreasing volume fraction of DBBM over time was observed. CONCLUSIONS The present study confirms previous findings that osseointegrated DBBM particles do not tend to undergo substitution over time. This low substitution rate may be the reason behind the clinically and radiographically documented long-term stability of contour augmentation using a combination of autogenous bone chips, DBBM particles, and a collagen membrane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSES Geriatric problems frequently go undetected in older patients in emergency departments (EDs), thus increasing their risk of adverse outcomes. We evaluated a novel emergency geriatric screening (EGS) tool designed to detect geriatric problems. BASIC PROCEDURES The EGS tool consisted of short validated instruments used to screen 4 domains (cognition, falls, mobility, and activities of daily living). Emergency geriatric screening was introduced for ED patients 75 years or older throughout a 4-month period. We analyzed the prevalence of abnormal EGS and whether EGS increased the number of EGS-related diagnoses in the ED during the screening, as compared with a preceding control period. MAIN FINDINGS Emergency geriatric screening was performed on 338 (42.5%) of 795 patients presenting during screening. Emergency geriatric screening was unfeasible in 175 patients (22.0%) because of life-threatening conditions and was not performed in 282 (35.5%) for logistical reasons. Emergency geriatric screening took less than 5 minutes to perform in most (85.8%) cases. Among screened patients, 285 (84.3%) had at least 1 abnormal EGS finding. In 270 of these patients, at least 1 abnormal EGS finding did not result in a diagnosis in the ED and was reported for further workup to subsequent care. During screening, 142 patients (42.0%) had at least 1 diagnosis listed within the 4 EGS domains, significantly more than the 29.3% in the control period (odds ratio 1.75; 95% confidence interval, 1.34-2.29; P<.001). Emergency geriatric screening predicted nursing home admission after the in-hospital stay (odds ratio for ≥3 vs <3 abnormal domains 12.13; 95% confidence interval, 2.79-52.72; P=.001). PRINCIPAL CONCLUSIONS The novel EGS is feasible, identifies previously undetected geriatric problems, and predicts determinants of subsequent care.