3 resultados para 658.404 M488a

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To determine the pulmonary venous flow velocity (PVFV) values in a large normal population. DESIGN Prospective study in consecutive individuals. SETTING University hospital. METHODS Among 404 normal individuals, the flow velocity pattern in the right upper pulmonary vein was recorded in 315 subjects using transthoracic echocardiography, and in both upper pulmonary veins in 100 subjects using transoesophageal echocardiography. Subjects were divided into five age groups. The PVFV values were compared between transthoracic and transoesophageal echocardiography within the age groups, and intraindividually between the right and left upper pulmonary veins in transoesophageal echocardiography. RESULTS Normal PVFV values for the right upper pulmonary vein in transthoracic and transoesophageal echocardiography are presented. The duration of flow reversal at atrial contraction was overestimated using transthoracic echocardiography (mean (SD): 96 (21) ms in transoesophageal echocardiography, 120 (28) ms in transthoracic echocardiography, p < 0.0001). Systolic to diastolic peak flow velocity ratio (S:D) increased earlier with advancing age with transoesophageal echocardiography than with transthoracic echocardiography. Similar results were found for the corresponding time-velocity integrals. Data from the left and right upper pulmonary veins differed with respect to onset and deceleration of flow velocities, but not for flow durations or peak velocities. CONCLUSIONS Normal PVFV values generally show a wide range. The data presented will be of value in assessing left ventricular diastolic function and mitral regurgitation using the PVFV pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of the Cavalier trial was to evaluate the safety and performance of the Perceval sutureless aortic valve in patients undergoing aortic valve replacement (AVR). We report the 30-day clinical and haemodynamic outcomes from the largest study cohort with a sutureless valve. METHODS From February 2010 to September 2013, 658 consecutive patients (mean age 77.8 years; 64.4% females; mean logistic EuroSCORE 10.2%) underwent AVR in 25 European Centres. Isolated AVRs were performed in 451 (68.5%) patients with a less invasive approach in 219 (33.3%) cases. Of the total, 40.0% were octogenarians. Congenital bicuspid aortic valve was considered an exclusion criterion. RESULTS Implantation was successful in 628 patients (95.4%). In isolated AVR through sternotomy, the mean cross-clamp time and the cardiopulmonary bypass (CPB) time were 32.6 and 53.7 min, and with the less invasive approach 38.8 and 64.5 min, respectively. The 30-day overall and valve-related mortality rates were 3.7 and 0.5%, respectively. Valve explants, stroke and endocarditis occurred in 0.6, 2.1 and in 0.1% of cases, respectively. Preoperative mean and peak pressure gradients decreased from 44.8 and 73.24 mmHg to 10.24 and 19.27 mmHg at discharge, respectively. The mean effective orifice area improved from 0.72 to 1.46 cm(2). CONCLUSIONS The current 30-day results show that the Perceval valve is safe (favourable haemodynamic effect and low complication rate), and can be implanted with a fast and reproducible technique after a short learning period. Short cross-clamp and CPB times were achieved in both isolated and combined procedures. The Perceval valve represents a promising alternative to biological AVR, especially with a less invasive approach and in older patients.