36 resultados para 500 MHZ

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quantitative meta-analyses of randomized clinical trials investigating the specific therapeutic efficacy of homeopathic remedies yielded statistically significant differences compared to placebo. Since the remedies used contained mostly only very low concentrations of pharmacologically active compounds, these effects cannot be accounted for within the framework of current pharmacology. Theories to explain clinical effects of homeopathic remedies are partially based upon changes in diluent structure. To investigate the latter, we measured for the first time high-field (600/500 MHz) 1H T1 and T2 nuclear magnetic resonance relaxation times of H2O in homeopathic preparations with concurrent contamination control by inductively coupled plasma mass spectrometry (ICP-MS). Homeopathic preparations of quartz (10c–30c, n = 21, corresponding to iterative dilutions of 100−10–100−30), sulfur (13x–30x, n = 18, 10−13–10−30), and copper sulfate (11c–30c, n = 20, 100−11–100−30) were compared to n = 10 independent controls each (analogously agitated dilution medium) in randomized and blinded experiments. In none of the samples, the concentration of any element analyzed by ICP-MS exceeded 10 ppb. In the first measurement series (600 MHz), there was a significant increase in T1 for all samples as a function of time, and there were no significant differences between homeopathic potencies and controls. In the second measurement series (500 MHz) 1 year after preparation, we observed statistically significant increased T1 relaxation times for homeopathic sulfur preparations compared to controls. Fifteen out of 18 correlations between sample triplicates were higher for controls than for homeopathic preparations. No conclusive explanation for these phenomena can be given at present. Possible hypotheses involve differential leaching from the measurement vessel walls or a change in water molecule dynamics, i.e., in rotational correlation time and/or diffusion. Homeopathic preparations thus may exhibit specific physicochemical properties that need to be determined in detail in future investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Millennial variability is a robust feature of many paleoclimate records, at least throughout the last several glacial cycles. Here we use the mean signal from Antarctic climate events 1 to 4 to probe the EPICA Dome C temperature proxy reconstruction through the last 500 ka for similar millennial-scale events. We find that clusters of millennial events occurred in a regular fashion over half of the time during this with a mean recurrence interval of 21 kyr. We find that there is no consistent link between ice-rafted debris deposition and millennial variability. Instead we speculate that changes in the zonality of atmospheric circulation over the North Atlantic form a viable alternative to freshwater release from icebergs as a trigger for millennial variability. We suggest that millennial changes in the zonality of atmospheric circulation over the North Atlantic are linked to precession via sea-ice feedbacks and that this relationship is modified by the presence of the large, Northern Hemisphere ice sheets during glacial periods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using data from a large European collaborative study, we aimed to identify the circumstances in which treated HIV-infected individuals will experience similar mortality rates to those of the general population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tree rings dominate millennium-long temperature reconstructions and many records originate from Scandinavia, an area for which the relative roles of external forcing and internal variation on climatic changes are, however, not yet fully understood. Here we compile 1,179 series of maximum latewood density measurements from 25 conifer sites in northern Scandinavia, establish a suite of 36 subset chronologies, and analyse their climate signal. A new reconstruction for the 1483–2006 period correlates at 0.80 with June–August temperatures back to 1860. Summer cooling during the early 17th century and peak warming in the 1930s translate into a decadal amplitude of 2.9°C, which agrees with existing Scandinavian tree-ring proxies. Climate model simulations reveal similar amounts of mid to low frequency variability, suggesting that internal ocean-atmosphere feedbacks likely influenced Scandinavian temperatures more than external forcing. Projected 21st century warming under the SRES A2 scenario would, however, exceed the reconstructed temperature envelope of the past 1,500 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress urinary incontinence (SUI) is common, impacts women's quality of life, and generates high costs. Physiotherapy is the first-line therapy, and if it fails, suburethral slings are the gold standard in SUI surgery. Bulking agents injected periurethrally might be a beneficial alternative, but there is a paucity of data on bulking therapy. The aim of this study was to prospectively analyze the efficacy and safety of bulking agents in the setting of a tertiary referral center.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the results of a unique "natural experiment" of the operation and cessation of a broadcast transmitter with its short-wave electromagnetic fields (6-22 MHz) on sleep quality and melatonin cycle in a general human population sample. In 1998, 54 volunteers (21 men, 33 women) were followed for 1 week each before and after shut-down of the short-wave radio transmitter at Schwarzenburg (Switzerland). Salivary melatonin was sampled five times a day and total daily excretion and acrophase were estimated using complex cosinor analysis. Sleep quality was recorded daily using a visual analogue scale. Before shut down, self-rated sleep quality was reduced by 3.9 units (95% CI: 1.7-6.0) per mA/m increase in magnetic field exposure. The corresponding decrease in melatonin excretion was 10% (95% CI: -32 to 20%). After shutdown, sleep quality improved by 1.7 units (95% CI: 0.1-3.4) per mA/m decrease in magnetic field exposure. Melatonin excretion increased by 15% (95% CI: -3 to 36%) compared to baseline values suggesting a rebound effect. Stratified analyses showed an exposure effect on melatonin excretion in poor sleepers (26% increase; 95% CI: 8-47%) but not in good sleepers. Change in sleep quality and melatonin excretion was related to the extent of magnetic field reduction after the transmitter's shut down in poor but not good sleepers. However, blinding of exposure was not possible in this observational study and this may have affected the outcome measurements in a direct or indirect (psychological) way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The CD4 T cell count recovery in human immunodeficiency virus type 1 (HIV-1)-infected individuals receiving potent antiretroviral therapy (ART) shows high variability. We studied the determinants and the clinical relevance of incomplete CD4 T cell restoration. METHODS: Longitudinal CD4 T cell count was analyzed in 293 participants of the Swiss HIV Cohort Study who had had a plasma HIV-1 RNA load <1000 copies/mL for > or =5 years. CD4 T cell recovery was stratified by CD4 T cell count 5 years after initiation of ART (> or =500 cells/microL was defined as a complete response, and <500 cells/microL was defined as an incomplete response). Determinants of incomplete responses and clinical events were evaluated using logistic regression and survival analyses. RESULTS: The median CD4 T cell count increased from 180 cells/microL at baseline to 576 cells/microL 5 years after ART initiation. A total of 35.8% of patients were incomplete responders, of whom 47.6% reached a CD4 T cell plateau <500 cells/microL. Centers for Disease Control and Prevention HIV-1 disease category B and/or C events occurred in 21% of incomplete responders and in 14.4% of complete responders (P>.05). Older age (adjusted odds ratio [aOR], 1.71 per 10-year increase; 95% confidence interval [CI], 1.21-2.43), lower baseline CD4 T cell count (aOR, 0.37 per 100-cell increase; 95% CI, 0.28-0.49), and longer duration of HIV infection (aOR, 2.39 per 10-year increase; 95% CI, 1.19-4.81) were significantly associated with a CD4 T cell count <500 cells/microL at 5 years. The median increases in CD4 T cell count after 3-6 months of ART were smaller in incomplete responders (P<.001) and predicted, in conjunction with baseline CD4 T cell count and age, incomplete response with 80% sensitivity and 72% specificity. CONCLUSION: Individuals with incomplete CD4 T cell recovery to <500 cells/microL had more advanced HIV-1 infection at baseline. CD4 T cell changes during the first 3-6 months of ART already reflect the capacity of the immune system to replenish depleted CD4 T lymphocytes.