2 resultados para 3RD-GENERATION BIOSENSOR

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Four studies, including two being published as an abstract, have recently demonstrated the feasibility of oral treatment of pyelonephritis in children, with no increased risk of treatment failure, early urinary tract re-infection, or renal scars. To do so, the pediatrician must ensure that: (1) the patient does not appear toxic, has no vomiting; (2) there is no known severe obstructive or refluxing uropathy and (3) parents are deemed to be adherent to the treatment. If these criteria are fulfilled, the pediatrician can start an oral treatment with a 3rd generation cephalosporine for 10 to 14 days. Ambulatory follow-up is crucial, and persistance of fever after 3 days is a reason for a new outpatient visit, additional or supplementary imaging studies (renal ultrasonography) and eventually a switch to intravenous treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.