23 resultados para 3Helium Hyperpolarisation MRT

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factors such as instability and impingement lead to early cartilage damage and osteoarthritis of the hip joint. The surgical outcome of joint-preserving surgery about the hip joint depends on the preoperative quality of joint cartilage.For in vivo evaluation of cartilage quality, different biochemically sensitive magnetic resonance imaging (MRI) procedures have been tested, some of which have the potential of inducing a paradigm shift in the evaluation and treatment of cartilage damage and early osteoarthritis.Instead of reacting to late sequelae in a palliative way, physicians could assess cartilage damage early on, and the treatment intensity could be adequate and based on the disease stage. Furthermore, the efficiency of different therapeutic interventions could be evaluated and monitored.This article reviews the recent application of delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and discusses its use for assessing cartilage quality in the hip joint. dGEMRIC is more sensitive to early cartilage changes in osteoarthritis than are radiographic measures and might be a helpful tool for assessing cartilage quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Malignant rhabdoid tumor (MRT) of the liver is a rare malignancy with grave prognosis. This entity should be considered in the differential diagnosis of any aggressive liver tumor with low levels of alpha fetoprotein. We report 2 cases of hepatic MRT presenting in infancy. In these 2 cases, we show that loss of INI1 facilitates making the correct diagnosis of primary hepatic MRT utilizing BAF 47 (INI1 gene product) immunostains. Difficulty encountered in making this rare diagnosis, including the need for repeated biopsies, can be avoided if MRT is considered in the differential diagnosis early on and BAF 47 immunohistochemistry is ordered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zielsetzung In dieser Arbeit soll ein speziell zur extrakorporalen Organperfusion entwickeltes, MR-kompatibles System vorgestellt werden, das die Durchführung wirklichkeitsnaher Experimente im MRT erlaubt. Methodik Es wurden explantierte Schweinelebern unter kontinuierlicher Hämoperfusion im geschlossenen 1.5T MRT untersucht. Während der Untersuchungen wurde das explantierte Organ mit einem neu entwickelten Perfusionssystem unter physiologischen Bedingungen, mit Hämodialyse und Oxygenierung, mit Blut perfundiert und vital erhalten. Es wurden MR-Sequenzen der diagnostischen und interventionellen Untersuchungen des klinischen Betriebes verwendet. Ergebnisse Das evaluierte System erwies sich als vollständig MR-kompatibel. Die erreichte Bildqualität der verwendeten Sequenzen zeigte eine hohe anatomische Detailerkennbarkeit. Geplante Experimente ließen sich kurzfristig und mit vergleichsweise geringem Aufwand durchführen. Sowohl diagnostische als auch interventionelle Untersuchungen ließen sich durchführen. Die verwendeten Organe zeigten eine stabile Funktion innerhalb physiologischer Parameter bis zu 4 Stunden. Schlussfolgerungen Mit dem verwendeten MR-kompatiblen Organperfusionssystem lassen sich bildgestützte experimentelle Interventionen und thermale Ablationen an explantierten Organen unter In-vivo-Bedingungen durchführen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To quantify the late dose-related responses of the rat cervical spinal cord to X-ray irradiations by an array of microbeams or by a single millimeter beam. MATERIALS AND METHODS: Necks of anesthetized rats were irradiated transversely by an 11mm wide array of 52 parallel, 35μm wide, vertical X-ray microbeams, separated by 210μm intervals between centers. Comparison was made with rats irradiated with a 1.35mm wide single beam of similar X-rays. Rats were killed when paresis developed, or up to 383days post irradiation (dpi). RESULTS: Microbeam peak/valley doses of ≈357/12.7Gy to 715/25.4Gy to an 11mm long segment of the spinal cord, or single beam doses of ≈146-454Gy to a 1.35mm long segment caused foreleg paresis and histopathologically verified spinal cord damage; rats exposed to peak/valley doses up to 253/9Gy were paresis-free at 383dpi. CONCLUSIONS: Whereas microbeam radiation therapy [MRT] for malignant gliomas implanted in rat brains can be safe, palliative or curative, the high tolerance of normal rat spinal cords to similar microbeam exposures justifies testing MRT for autochthonous malignancies in the central nervous system of larger animals with a view to subsequent clinical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microbeam radiation therapy (MRT), a preclinical form of radiosurgery, uses spatially fractionated micrometre-wide synchrotron-generated X-ray beams. As MRT alone is predominantly palliative for animal tumors, the effects of the combination of MRT and a newly synthesized chemotherapeutic agent JAI-51 on 9L gliosarcomas have been evaluated. Fourteen days (D14) after implantation (D0), intracerebral 9LGS-bearing rats received either MRT, JAI-51 or both treatments. JAI-51, alone or immediately after MRT, was administered three times per week. Animals were kept up to ∼20 weeks after irradiation or sacrificed at D16 or D28 after treatment for cell cycle analysis. MRT plus JAI-51 increased significantly the lifespan compared with MRT alone (p = 0.0367). JAI-51 treatment alone had no effect on rat survival. MRT alone or associated with JAI-51 induced a cell cycle blockade in G2/M (p < 0.01) while the combined treatment also reduced the proportion of G0/G1 cells. At D28 after irradiation, MRT and MRT/JAI-51 had a smaller cell blockade effect in the G2/M phase owing to a significant increase in tumor cell death rate (<2c) and a proportional increase of endoreplicative cells (>8c). The combination of MRT and JAI-51 increases the survival of 9LGS-bearing rats by inducing endoreduplication of DNA and tumor cell death; further, it slowed the onset of tumor growth resumption two weeks after treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lameness in horses due to pain originating from the proximal metacarpal/metatarsal region remains a diagnostic challenge. In cases of obvious lameness the pain can be localised to this region by diagnostic anaesthesia. Because a variety of disorders can cause lameness in this region different imaging modalities including radiography, ultrasonography and scintigraphy should be used to arrive at an accurate diagnosis. Even though a precise anatomic-pathologic diagnosis can still be an enigma, because not only bone and joints, but also soft tissue structures including the proximal suspensory ligament, its origin at the proximal metacarpus/ metatarsus, its fascia, the superficial fascia, as well as the intermetacarpal/metatarsal ligaments, the accessory ligament of the deep digital flexor tendon and both digital flexor tendons may be involved. Magnet resonance tomography (MRT) shows a high diagnostic sensitivity in imaging soft tissue structures and bone. In horses MRT is still at the beginning. The MRT appearance of the proximal metacarpal/metatarsal region has not yet been evaluated in detail and there are only few anatomic studies of the origin of the suspensory ligament in horses. The first experiences showed, that more gross and histologic examinations are necessary to fully interpret MRT-images and to differentiate pathologic alterations from clinically not relevant variations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microbeam radiation therapy (MRT), a form of experimental radiosurgery of tumours using multiple parallel, planar, micrometres-wide, synchrotron-generated X-ray beams ('microbeams'), can safely deliver radiation doses to contiguous normal animal tissues that are much higher than the maximum doses tolerated by the same normal tissues of animals or patients from any standard millimetres-wide radiosurgical beam. An array of parallel microbeams, even in doses that cause little damage to radiosensitive developing tissues, for example, the chick chorioallantoic membrane, can inhibit growth or ablate some transplanted malignant tumours in rodents. The cerebella of 100 normal 20 to 38g suckling Sprague-Dawley rat pups and of 13 normal 5 to 12kg weanling Yorkshire piglets were irradiated with an array of parallel, synchrotron-wiggler-generated X-ray microbeams in doses overlapping the MRT-relevant range (about 50-600Gy) using the ID17 wiggler beamline tangential to the 6GeV electron synchrotron ring at the European Synchrotron Radiation Facility in Grenoble, France. Subsequent favourable development of most animals over at least 1 year suggests that MRT might be used to treat children's brain tumours with less risk to the development of the central nervous system than is presently the case when using wider beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although low-density lipoprotein (LDL) cholesterol is often normal in patients with type 2 diabetes mellitus, there is evidence for a reduced fractional catabolic rate and consequently an increased mean residence time (MRT), which can increase atherogenic risk. The dyslipidemia and insulin resistance of type 2 diabetes mellitus can be improved by aerobic exercise, but effects on LDL kinetics are unknown. The effect of 6-month supervised exercise on LDL apolipoprotein B kinetics was studied in a group of 17 patients with type 2 diabetes mellitus (mean age, 56.8 years; range, 38-68 years). Patients were randomized into a supervised group, who had a weekly training session, and an unsupervised group. LDL kinetics were measured with an infusion of 1-(13)C leucine at baseline in all groups and after 6 months of exercise in the patients. Eight body mass index-matched nondiabetic controls (mean age, 50.3 years; range, 40-67 years) were also studied at baseline only. At baseline, LDL MRT was significantly longer in the diabetic patients, whereas LDL production rate and fractional clearance rates were significantly lower than in controls. Percentage of glycated hemoglobin A(1c), body mass index, insulin sensitivity measured by the homeostasis model assessment, and very low-density lipoprotein triglyceride decreased (P < .02) in the supervised group, with no change in the unsupervised group. After 6 months, LDL cholesterol did not change in either the supervised or unsupervised group; but there was a significant change in LDL MRT between groups (P < .05) that correlated positively with very low-density lipoprotein triglyceride (r = 0.51, P < .04) and negatively with maximal oxygen uptake, a measure of fitness (r = -0.51, P = .035), in all patients. The LDL production and clearance rates did not change in either group. This study suggests that a supervised exercise program can reduce deleterious changes in LDL MRT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Synchrotron microbeam radiation therapy (MRT) is an innovative irradiation modality based on spatial fractionation of a high-dose X-ray beam into lattices of microbeams. The increase in lifespan of brain tumor-bearing rats is associated with vascular damage but the physiological consequences of MRT on blood vessels have not been described. In this manuscript, we evaluate the oxygenation changes induced by MRT in an intracerebral 9L gliosarcoma model. METHODS Tissue responses to MRT (two orthogonal arrays (2 × 400Gy)) were studied using magnetic resonance-based measurements of local blood oxygen saturation (MR_SO2) and quantitative immunohistology of RECA-1, Type-IV collagen and GLUT-1, marker of hypoxia. RESULTS In tumors, MR_SO2 decreased by a factor of 2 in tumor between day 8 and day 45 after MRT. This correlated with tumor vascular remodeling, i.e. decrease in vessel density, increases in half-vessel distances (×5) and GLUT-1 immunoreactivity. Conversely, MRT did not change normal brain MR_SO2, although vessel inter-distances increased slightly. CONCLUSION We provide new evidence for the differential effect of MRT on tumor vasculature, an effect that leads to tumor hypoxia. As hypothesized formerly, the vasculature of the normal brain exposed to MRT remains sufficiently perfused to prevent any hypoxia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchrotron Microbeam Radiation Therapy (MRT) relies on the spatial fractionation of the synchrotron photon beam into parallel micro-beams applying several hundred of grays in their paths. Several works have reported the therapeutic interest of the radiotherapy modality at preclinical level, but biological mechanisms responsible for the described efficacy are not fully understood to date. The aim of this study was to identify the early transcriptomic responses of normal brain and glioma tissue in rats after MRT irradiation (400Gy). The transcriptomic analysis of similarly irradiated normal brain and tumor tissues was performed 6 hours after irradiation of 9 L orthotopically tumor-bearing rats. Pangenomic analysis revealed 1012 overexpressed and 497 repressed genes in the irradiated contralateral normal tissue and 344 induced and 210 repressed genes in tumor tissue. These genes were grouped in a total of 135 canonical pathways. More than half were common to both tissues with a predominance for immunity or inflammation (64 and 67% of genes for normal and tumor tissues, respectively). Several pathways involving HMGB1, toll-like receptors, C-type lectins and CD36 may serve as a link between biochemical changes triggered by irradiation and inflammation and immunological challenge. Most immune cell populations were involved: macrophages, dendritic cells, natural killer, T and B lymphocytes. Among them, our results highlighted the involvement of Th17 cell population, recently described in tumor. The immune response was regulated by a large network of mediators comprising growth factors, cytokines, lymphokines. In conclusion, early response to MRT is mainly based on inflammation and immunity which appear therefore as major contributors to MRT efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess liver remnant volume regeneration and maintenance, and complications in the long-time follow-up of donors after living donor liver transplantation using CT and MRI. Materials and Methods: 47 donors with a mean age of 33.5 years who donated liver tissue for transplantation and who were available for follow-up imaging were included in this retrospective study. Contrast-enhanced CT and MR studies were acquired for routine follow-up. Two observers evaluated pre- and postoperative images regarding anatomy and pathological findings. Volumes were manually measured on contrast-enhanced images in the portal venous phase, and potential postoperative complications were documented. Pre- and postoperative liver volumes were compared for evaluating liver remnant regeneration. Results: 47 preoperative and 89 follow-up studies covered a period of 22.4 months (range: 1 - 84). After right liver lobe (RLL) donation, the mean liver remnant volume was 522.0 ml (± 144.0; 36.1 %; n = 18), after left lateral section (LLS) donation 1,121.7 ml (± 212.8; 79.9 %; n = 24), and after left liver lobe (LLL) donation 1,181.5 ml (± 279.5; 72.0 %; n = 5). Twelve months after donation, the liver remnant volume were 87.3 % (RLL; ± 11.8; n = 11), 95.0 % (LS; ± 11.6; n = 18), and 80.1 % (LLL; ± 2.0; n = 2 LLL) of the preoperative total liver volume. Rapid initial regeneration and maintenance at 80 % of the preoperative liver volume were observed over the total follow-up period. Minor postoperative complications were found early in 4 patients. No severe or late complications or mortality occurred. Conclusion: Rapid regeneration of liver remnant volumes in all donors and volume maintenance over the long-term follow-up period of up to 84 months without severe or late complications are important observations for assessing the safety of LDLT donors. Key Points: Liver remnant volumes of LDLT donors rapidly regenerated after donation and volumes were maintained over the long-term follow-up period of up to 84 months without severe or late complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Virtopsy ist eine progressive bildgebende Methode der Rechtsmedizin, mit welcher außergewöhnliche Todesfälle oder auch Verletzungen lebender Personen (klinisch forensische Bildgebung) untersucht werden können. Genutzt werden hierfür bildgebende Verfahren wie z. B. CT und MRT. Die Virtopsy an Verstorbenen bringt verschiedene Vorteile gegenüber einer Autopsie mit sich, wie beispielsweise die verständliche 3D-Darstellung. Demgegenüber ergeben sich aber auch Nachteile, wie etwa der Umstand, dass Organfarben nicht sichtbar sind. Per saldo überwiegen jedoch die Vorteile, insbesondere genießen bildgebende Untersuchungen bei Angehörigen aus Gründen der Pietät und der Religion eine größere Akzeptanz als konventionelle Leichenöffnungen. Die Virtopsy kann sowohl eine Autopsie ergänzen als auch eine Autopsie-Entscheidung erleichtern, indem sie Letzterer vorausgeht. David Alexander Zimmermann beschreibt in einer ersten monografischen Abhandlung zum Thema den umfassenden rechtlichen Rahmen für bildgebende Verfahren in der Forensik. Die rechtliche Diskussion umfasst dabei die Interpretation und Vergleichung rechtlicher Quellen sowohl aus verschiedenen Ländern wie z. B. Australien, Deutschland, Schweiz und USA, als auch aus unterschiedlichen Rechtsgebieten. Dabei richtet der Autor seinen Fokus auf die Festlegung gesetzlicher Grundlagen für forensische Bildgebung / Virtopsy und deren Zulässigkeit in Strafverfahren.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM To investigate risk factors for the loss of multi-rooted teeth (MRT) in subjects treated for periodontitis and enrolled in supportive periodontal therapy (SPT). MATERIAL AND METHODS A total of 172 subjects were examined before (T0) and after active periodontal therapy (APT)(T1) and following a mean of 11.5 ± 5.2 (SD) years of SPT (T2). The association of risk factors with loss of MRT was analysed with multilevel logistic regression. The tooth was the unit of analysis. RESULTS Furcation involvement (FI) = 1 before APT was not a risk factor for tooth loss compared with FI = 0 (p = 0.37). Between T0 and T2, MRT with FI = 2 (OR: 2.92, 95% CI: 1.68, 5.06, p = 0.0001) and FI = 3 (OR: 6.85, 95% CI: 3.40, 13.83, p < 0.0001) were at a significantly higher risk to be lost compared with those with FI = 0. During SPT, smokers lost significantly more MRT compared with non-smokers (OR: 2.37, 95% CI: 1.05, 5.35, p = 0.04). Non-smoking and compliant subjects with FI = 0/1 at T1 lost significantly less MRT during SPT compared with non-compliant smokers with FI = 2 (OR: 10.11, 95% CI: 2.91, 35.11, p < 0.0001) and FI = 3 (OR: 17.18, 95% CI: 4.98, 59.28, p < 0.0001) respectively. CONCLUSIONS FI = 1 was not a risk factor for tooth loss compared with FI = 0. FI = 2/3, smoking and lack of compliance with regular SPT represented risk factors for the loss of MRT in subjects treated for periodontitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Virtopsy ist eine progressive bildgebende Methode der Rechtsmedizin, mit welcher außergewöhnliche Todesfälle oder auch Verletzungen lebender Personen (klinisch forensische Bildgebung) untersucht werden können. Genutzt werden hierfür bildgebende Verfahren wie z. B. CT und MRT. Die Virtopsy an Verstorbenen bringt verschiedene Vorteile gegenüber einer Autopsie mit sich, wie beispielsweise die verständliche 3D-Darstellung. Demgegenüber ergeben sich aber auch Nachteile, wie etwa der Umstand, dass Organfarben nicht sichtbar sind. Per saldo überwiegen jedoch die Vorteile, insbesondere genießen bildgebende Untersuchungen bei Angehörigen aus Gründen der Pietät und der Religion eine größere Akzeptanz als konventionelle Leichenöffnungen. Die Virtopsy kann sowohl eine Autopsie ergänzen als auch eine Autopsie-Entscheidung erleichtern, indem sie Letzterer vorausgeht. David Alexander Zimmermann beschreibt in einer ersten monografischen Abhandlung zum Thema den umfassenden rechtlichen Rahmen für bildgebende Verfahren in der Forensik. Die rechtliche Diskussion umfasst dabei die Interpretation und Vergleichung rechtlicher Quellen sowohl aus verschiedenen Ländern wie z. B. Australien, Deutschland, Schweiz und USA, als auch aus unterschiedlichen Rechtsgebieten. Dabei richtet der Autor seinen Fokus auf die Festlegung gesetzlicher Grundlagen für forensische Bildgebung / Virtopsy und deren Zulässigkeit in Strafverfahren.