18 resultados para 3899

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stress response can be considered a consequence of psychological or physiological threats to the human organism. Elevated cortisol secretion represents a biological indicator of subjective stress. The extent of subjectively experienced stress depends on individual coping strategies or self-regulation skills. Because of their experience with competitive pressure, athletes might show less pronounced biological stress responses during stressful events compared to non-athletes. In the present study, the short version of the Berlin Intelligence Structure Test, a paper-pencil intelligence test, was used as an experimental stressor. Cortisol responses of 26 female Swiss elite athletes and 26 female non-athlete controls were compared. Salivary free cortisol responses were measured 15 minutes prior to, as well as immediately before and after psychometric testing. In both groups, a significant effect of time was found: High cortisol levels prior to testing decreased significantly during the testing session. Furthermore, athletes exhibited reliably lower cortisol levels than non-athlete controls. No significant interaction effects could be observed. The overall pattern of results supports the idea that elite athletes show a less pronounced cortisol-related stress response due to more efficient coping strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the most recent work of the OMERACT Ultrasound Task Force (post OMERACT 8) and highlights of future research priorities discussed at the OMERACT 9 meeting, Kananaskis, Canada, May 2008. Results of 3 studies were presented: (1) assessing intermachine reliability; (2) applying the scoring system developed in the hand to other joints most commonly affected in rheumatoid arthritis (RA); and (3) assessing interobserver reliability on a deep target joint (shoulder). Results demonstrated good intermachine reliability between multiple examiners, and good applicability of the scoring system for the hand on other joints (including shoulder). Study conclusions were discussed and a future research agenda was generated, notably the further development of a Global OMERACT Sonography Scoring (GLOSS) system in RA, emphasizing the importance of testing feasibility and added value over standard clinical variables. Future disease areas of importance to develop include a scoring system for enthesitis and osteoarthritis.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cochrane Musculoskeletal Group (CMSG), one of 53 groups of the not-for-profit, international Cochrane Collaboration, prepares, maintains, and disseminates systematic reviews of treatments for musculoskeletal diseases. It is important that authors conducting CMSG reviews and the readers of our reviews be aware of and use updated, state-of-the-art systematic review methodology. One hundred sixty reviews have been published. Previous method guidelines for systematic reviews of interventions in the musculoskeletal field published in 2006 have been substantially updated to incorporate methodological advances that are mandatory or highly desirable in Cochrane reviews and knowledge translation advances. The methodological advances include new guidance on searching, new risk-of-bias assessment, grading the quality of the evidence, the new Summary of Findings table, and comparative effectiveness using network metaanalysis. Method guidelines specific to musculoskeletal disorders are provided by CMSG editors for various aspects of undertaking a systematic review. These method guidelines will help improve the quality of reporting and ensure high standards of conduct as well as consistency across CMSG reviews.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TheXENON100 experiment, installed underground at the LaboratoriNazionali del Gran Sasso, aims to directly detect dark matter in the form of weakly interacting massive particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from (alpha, n) reactions and spontaneous fission due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on MonteCarlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by theXENON100 experiment in 2011 and 2012, 0.11(-0.04)(+0.08) events and 0.17(-0.07)(+0.12) events, respectively, and conclude that they do not limit the sensitivity of the experiment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the initiation of and response to tumor necrosis factor (TNF) inhibitors for axial spondyloarthritis (axSpA) in private rheumatology practices versus academic centers. METHODS We compared newly initiated TNF inhibition for axSpA in 363 patients enrolled in private practices with 100 patients recruited in 6 university hospitals within the Swiss Clinical Quality Management (SCQM) cohort. RESULTS All patients had been treated with ≥ 1 nonsteroidal antiinflammatory drug and > 70% of patients had a baseline Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) ≥ 4 before anti-TNF agent initiation. The proportion of patients with nonradiographic axSpA (nr-axSpA) treated with TNF inhibitors was higher in hospitals versus private practices (30.4% vs 18.7%, p = 0.02). The burden of disease as assessed by patient-reported outcomes at baseline was slightly higher in the hospital setting. Mean levels (± SD) of the Ankylosing Spondylitis Disease Activity Score were, however, virtually identical in private practices and academic centers (3.4 ± 1.0 vs 3.4 ± 0.9, p = 0.68). An Assessment of SpondyloArthritis international Society (ASAS40) response at 1 year was reached for ankylosing spondylitis in 51.7% in private practices and 52.9% in university hospitals (p = 1.0) and for nr-axSpA in 27.5% versus 25.0%, respectively (p = 1.0). CONCLUSION With the exception of a lower proportion of patients with nr-axSpA newly treated with anti-TNF agents in private practices in comparison to academic centers, adherence to ASAS treatment recommendations for TNF inhibition was equally high, and similar response rates to TNF blockers were achieved in both clinical settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Abatacept (ABA), a selective T cell costimulation modulator that binds to CD80 and CD86 on antigen-presenting cells, was investigated for its antiinflammatory effect in treating severe chronic uveitis associated with juvenile idiopathic arthritis (JIA). METHODS Our retrospective study was conducted by members of the Multinational Interdisciplinary Working Group for Uveitis in Childhood (MIWGUC). Patients with JIA who are receiving ABA treatment for active uveitis were included. In all patients, uveitis had been refractory to previous topical and systemic corticosteroids, immunosuppressives, and at least 1 tumor necrosis factor-α inhibitor. A standardized protocol was used to document uveitis (MIWGUC) and arthritis. Baseline visit and visits at 3, 6, 9, and 12 months before and after ABA start were evaluated. Primary outcome measure was defined as achievement of uveitis inactivity; secondary outcome measures were tapering of corticosteroid and/or immunosuppressive treatment, and occurrence of complications. RESULTS In all, 21 patients (16 female) with active uveitis (n = 21) and arthritis (n = 18) were included (mean age 11.8 ± 3.6 yrs). In 7 of 18 patients with active arthritis at baseline, inactivity was achieved following ABA treatment. Uveitis inactivity was achieved in 11 patients, but recurred later in 8 of them, and remained active in another 10 cases. Systemic corticosteroids or immunosuppression were tapered in 3 patients, but uveitis recurred in all of them during further followup. Ocular complications secondary to uveitis were present in 17 patients at baseline, while 3 patients developed new ocular complications during followup. CONCLUSION A sustained response to ABA was uncommon in patients with severe and refractory uveitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ligand 1,2-bis(1H-benzimidazol-2-yl)-1,2-ethanediol, 1, and its methylated derivative 2 are readily synthesized from tartaric acid, and act as chiral, facially coordinating tridentate ligands, forming complexes of composition ML2 with octahedral transition metals. The copper(II) complexes show distorted 4 + 2 coordination with benzimidazoles occupying the equatorial sites and alcohol functions weakly binding in the axial sites. Nickel(II) complexes in three different states of protonation show regular octahedral geometry with the alcohols mutually cis. Deprotonation of the coordinated alcohol produces little structural change but the monodeprotonated complex forms a hydrogen bonded dimer. Magnetic measurements show the hydrogen bonded bridge to offer a pathway for weak antiferromagnetic coupling. UV-Visible spectroscopy shows the ligand to have a field intermediate between water and pyridine. The diastereoselectivity of complexation depends on the geometry: nickel(II) shows a weak preference for the homochiral complex, whereas copper(II) forms almost exclusively homochiral complexes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.