5 resultados para 226
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: This study investigated the role of a negative FAST in the diagnostic and therapeutic algorithm of multiply injured patients with liver or splenic lesions. METHODS: A retrospective analysis of 226 multiply injured patients with liver or splenic lesions treated at Bern University Hospital, Switzerland. RESULTS: FAST failed to detect free fluid or organ lesions in 45 of 226 patients with spleen or liver injuries (sensitivity 80.1%). Overall specificity was 99.5%. The positive and negative predictive values were 99.4% and 83.3%. The overall likelihood ratios for a positive and negative FAST were 160.2 and 0.2. Grade III-V organ lesions were detected more frequently than grade I and II lesions. Without the additional diagnostic accuracy of a CT scan, the mean ISS of the FAST-false-negative patients would be significantly underestimated and 7 previously unsuspected intra-abdominal injuries would have been missed. CONCLUSION: FAST is an expedient tool for the primary assessment of polytraumatized patients to rule out high grade intra-abdominal injuries. However, the low overall diagnostic sensitivity of FAST may lead to underestimated injury patterns and delayed complications may occur. Hence, in hemodynamically stable patients with abdominal trauma, an early CT scan should be considered and one must be aware of the potential shortcomings of a "negative FAST".
Resumo:
AIMS Follicular thyroid carcinoma (FTC) has been a diagnostic challenge for decades. The PAX8-PPARγ rearrangement has been detected in FTC and classic papillary thyroid carcinomas (PTCs). The aims of this study were to assess the presence of PAX8-PPARγ by using tissue microarrays in a large cohort of different thyroid neoplasms, and to assess its diagnostic and prognostic implications. METHODS AND RESULTS Fluorescence in-situ hybridization (FISH) analysis for PAX8-PPARγ was performed on 226 thyroid tumours, comprising FTCs (n = 59), PTCs (n = 126), poorly differentiated thyroid carcinomas (PDs; n = 34), follicular thyroid adenomas (FTAs; n = 5), and follicular tumours of unknown malignant potential (FTUMPs; n = 2). PAX8-PPARγ was detected in 12% of FTCs, 1% of PTCs, 7% of PDs, and in both cases of FTUMP. There was no correlation between the extent of capsular or vascular invasion and PAX8-PPARγ, or between lymph node or haematogenous metastasis and PAX8-PPARγ. Overall survival (OS), tumour-specific survival (TSS) and relapse-free-survival (RFS) were not influenced by PAX8-PPARγ. CONCLUSIONS In this study, we demonstrate for the first time the presence of PAX8-PPARγ in PDs and FTUMPs, whereas in FTCs and PTCs the prevalence of PAX8-PPARγ is lower than previously reported. PAX8-PPARγ did not correlate with invasiveness or affect prognosis in any tumour type.
Resumo:
BACKGROUND The Journey bicruciate substituting (BCS) total knee replacement (TKR) is intended to improve knee kinematics by more closely approximating the surfaces of a normal knee. The purpose of this analysis was to address the safety of Journey BCS knees by studying early complication and revision rates in a consecutive case series. METHODS Between December 2006 and May 2011, a single surgeon implanted 226 Journey BCS total knee prostheses in 191 patients (124 women, 67 men) who were eligible for study. Mean age at surgery was 68 years (41-85 years).Outcome measures were early complications and minor and major revision rates. All complications were considered, irrespective of whether conservative treatment or revision was required. RESULTS The average implantation time was 3.5 years (range 1.3-5.8 years). Thirty-three complications (14.6% of 226 knees) required minor or major revision surgery in 25 patients. The remaining eight patients were treated conservatively. Sixteen minor revisions were performed in 12 patients. Thirteen major revisions were required in 13 patients, which results in a rate of 1.65 major revisions per 100 component years. The linear trend of the early complication rate by treatment year was not significant (p = .22).Multivariate logistic regression showed no significant predictors for the occurrence of a complication or for revision surgery. A tendency towards higher complication rates was observed in female patients, although it was not significant (p = .066). CONCLUSIONS The complication and revision rates of the Journey BCS knee implant are high in comparison with those reported for other established total knee systems. Caution is advised when using this implant, particularly for less experienced knee surgeons.