28 resultados para 200-1224
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To assess (1) how large-scale correlation of intracranial EEG signals in the high-frequency range (80-200Hz) evolves from the pre-ictal, through the ictal into the postictal state and (2) whether the contribution of local neuronal activity to large-scale EEG correlation differentiates epileptogenic from non-epileptogenic brain tissue.
Resumo:
Current guidelines suggest that primary prophylaxis for Pneumocystis jiroveci pneumonia (PcP) can be safely stopped in human immunodeficiency virus (HIV)-infected patients who are receiving combined antiretroviral therapy (cART) and who have a CD4 cell count >200 cells/microL. There are few data regarding the incidence of PcP or safety of stopping prophylaxis in virologically suppressed patients with CD4 cell counts of 101-200 cells/microL.
Resumo:
In Switzerland, more and more patients go directly to the emergency department, bypassing general practitioners. However, a mixture of non-urgent walk-in patients and acute emergencies in the same emergency department can inevitably make it more difficult to provide genuine emergencies with rapid treatment, leading to deterioration in the quality of emergency services, and tending to increase on-floor mortality and morbidity, together with higher overall costs.
Resumo:
In excisional body-contouring surgery the surgeon is often confronted with time-consuming closure of long wounds. Recently, a new combination of a self-adhering mesh together with a liquid 2-octyl cyanoacrylate adhesive (Prineo™; Ethicon, Inc., Somerville, NJ, USA) has been introduced to replace intracutaneous running suture.
Seismic evidence of up to 200 m lake-level change in Southern Patagonia since Marine Isotope Stage 4
Resumo:
The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 mu A C- out of gaseous samples with an efficiency of 3-6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3-30 mu g carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of C-14/C-12 could be repeated within statistical errors to better than 1.0% and the C-13/C-12 ratios to better than 0.2%. The blank was < 1 pMC.