7 resultados para 2-hydroxyethyl methacrylate copolymers
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Poly(ethylene oxide) (PEO) has long been used as an additive in toothpaste, partly because it reduces biofilm formation on teeth. It does not, however, reduce the formation of dental calculus or support the remineralization of dental enamel or dentine. The present article describes the synthesis of new block copolymers on the basis of PEO and poly(3-sulfopropyl methacrylate) blocks using atom transfer radical polymerization. The polymers have very large molecular weights (over 10(6) g/mol) and are highly water-soluble. They delay the precipitation of calcium phosphate from aqueous solution but, upon precipitation, lead to relatively monodisperse hydroxyapatite (HAP) spheres. Moreover, the polymers inhibit the bacterial colonization of human enamel by Streptococcus gordonii, a pioneer bacterium in oral biofilm formation, in vitro. The formation of well-defined HAP spheres suggests that a polymer-induced liquid precursor phase could be involved in the precipitation process. Moreover, the inhibition of bacterial adhesion suggests that the polymers could be utilized in caries prevention.
Resumo:
To study the changes in blood volume and hormones controlling sodium and water homeostasis after infusions of 0.9% saline, Gelofusine (4% succinylated gelatin in 0.7% saline, weight-average molecular weight 30 kD), and Voluven (6% hydroxyethyl starch in 0.9% saline, weight-average molecular weight 130 kD) in healthy volunteers.
Comparative stability studies of poly(2-methyl-2-oxazoline) and poly(ethylene glycol) brush coatings
Resumo:
Non-fouling surfaces that resist non-specific adsorption of proteins, bacteria, and higher organisms are of particular interest in diverse applications ranging from marine coatings to diagnostic devices and biomedical implants. Poly(ethylene glycol) (PEG) is the most frequently used polymer to impart surfaces with such non-fouling properties. Nevertheless, limitations in PEG stability have stimulated research on alternative polymers that are potentially more stable than PEG. Among them, we previously investigated poly(2-methyl-2-oxazoline) (PMOXA), a peptidomimetic polymer, and found that PMOXA shows excellent anti-fouling properties. Here, we compare the stability of films self-assembled from graft copolymers exposing a dense brush layer of PEG and PMOXA side chains, respectively, in physiological and oxidative media. Before media exposure both film types prevented the adsorption of full serum proteins to below the detection limit of optical waveguide in situ measurements. Before and after media exposure for up to 2 weeks, the total film thickness, chemical composition, and total adsorbed mass of the films were quantified using variable angle spectroscopic ellipsometry (VASE), X-ray photoelectron spectroscopy (XPS), and optical waveguide lightmode spectroscopy (OWLS), respectively. We found (i) that PMOXA graft copolymer films were significantly more stable than PEG graft copolymer films and kept their protein-repellent properties under all investigated conditions and (ii) that film degradation was due to side chain degradation rather than due to copolymer desorption.
Resumo:
AIM Preparation of the lamina during osteo-odonto-keratoprosthesis (OOKP) design is complex, and its longevity and watertightness important. To date, only acrylic bone cements have been used for bonding the optical cylinder to the tooth dentine. Our aim was to evaluate different dental adhesives for OOKP preparation. METHODS Specimens of bovine teeth were produced by preparing 1.5-mm thick dentine slices with holes having a diameter of 3.5 mm. Each group (n=10 per group) was luted with either classic poly-(methyl methacrylate) (PMMA) bone cement, universal resin cement or glass ionomer cement. All specimens underwent force measurement using a uniaxial traction machine. RESULTS The highest mean force required to break the bond was measured for PMMA bone cement (128.2 N) followed by universal resin cement (127.9 N), with no statistically significant difference. Glass ionomer cement showed significantly lower force resistance (78.1 N). CONCLUSIONS Excellent bonding strength combined with easy application was found for universal resin cement, and thus, it is a potential alternative to acrylic bone cement in OOKP preparation.
Resumo:
OBJECTIVE To compare the in vitro effects of hypertonic solutions and colloids to saline on coagulation in dogs. DESIGN In vitro experimental study. SETTING Veterinary teaching hospital. ANIMALS Twenty-one adult dogs. INTERVENTIONS Blood samples were diluted with saline, 7.2% hypertonic saline solution with 6% hydroxyethylstarch with an average molecular weight of 200 kDa and a molar substitution of 0.4 (HH), 7.2% hypertonic saline (HTS), hydroxyethyl starch (HES) 130/0.4 or hydroxyethyl starch 600/0.75 at ratios of 1:22 and 1:9, and with saline and HES at a ratio of 1:3. MEASUREMENTS AND MAIN RESULTS Whole blood coagulation was analyzed using rotational thromboelastometry (extrinsic thromboelastometry-cloting time (ExTEM-CT), maximal clot firmness (MCF) and clot formation time (CFT) and fibrinogen function TEM-CT (FibTEM-CT) and MCF) and platelet function was analyzed using a platelet function analyzer (closure time, CTPFA ). All parameters measured were impaired by saline dilution. The CTPFA was prolonged by 7.2% hypertonic saline solution with 6% hydroxyethylstarch with an average molecular weight of 200 kDa and a molar substitution of 0.4 (HH) and HTS but not by HES solutions. At clinical dilutions equivalent to those generally administered for shock (saline 1:3, HES 1:9, and hypertonic solutions 1:22), CTPFA was more prolonged by HH and HTS than other solutions but more by saline than HES. No difference was found between the HES solutions or the hypertonic solutions. ExTEM-CFT and MCF were impaired by HH and HTS but only mildly by HES solutions. At clinically relevant dilutions, no difference was found in ExTEM-CFT between HTS and saline or in ExTEM-MCF between HH and saline. No consistent difference was found between the 2 HES solutions but HH impaired ExTEM-CFT and MCF more than HTS. At high dilutions, FibTEM-CT and -MCF and ExTEM-CT were impaired by HES. CONCLUSIONS Hypertonic solutions affect platelet function and whole blood coagulation to a greater extent than saline and HES. At clinically relevant dilutions, only CTPFA was markedly more affected by hypertonic solutions than by saline. At high dilutions, HES significantly affects coagulation but to no greater extent than saline at clinically relevant dilutions.
Resumo:
OBJECTIVES: To (1) review the development and medical applications of hydroxyethyl starch (HES) solutions with particular emphasis on its physiochemical properties; (2) critically appraise the available evidence in human and veterinary medicine, and (3) evaluate the potential risks and benefits associated with their use in critically ill small animals. DATA SOURCES: Human and veterinary original research articles, scientific reviews, and textbook sources from 1950 to the present. HUMAN DATA SYNTHESIS: HES solutions have been used extensively in people for over 30 years and ever since its introduction there has been a great deal of debate over its safety and efficacy. Recently, results of seminal trials and meta-analyses showing increased risks related to kidney dysfunction and mortality in septic and critically ill patients, have led to the restriction of HES use in these patient populations by European regulatory authorities. Although the initial ban on the use of HES in Europe has been eased, proof regarding the benefits and safety profile of HES in trauma and surgical patient populations has been requested by these same European regulatory authorities. VETERINARY DATA SYNTHESIS: The veterinary literature is limited mostly to experimental studies and clinical investigations with small populations of patients with short-term end points and there is insufficient evidence to generate recommendations. CONCLUSIONS: Currently, there are no consensus recommendations regarding the use of HES in veterinary medicine. Veterinarians and institutions affected by the HES restrictions have had to critically reassess the risks and benefits related to HES usage based on the available information and sometimes adapt their procedures and policies based on their reassessment. Meanwhile, large, prospective, randomized veterinary studies evaluating HES use are needed to achieve relevant levels of evidence to enable formulation of specific veterinary guidelines.
Resumo:
OBJECTIVE To determine changes in creatinine concentrations following the administration of 6% tetrastarch (hydroxyethyl starch [HES] 130/0.4) compared to crystalloids (CRYSs) in critically ill dogs. DESIGN Retrospective case series (2010-2013). SETTING University teaching hospital. ANIMALS Two hundred and one dogs admitted to the intensive care unit with initial plasma creatinine concentrations not exceeding laboratory reference intervals (52-117 μmol/L [0.6-1.3 mg/dL]) and receiving either CRYSs alone (CRYS group, n = 115) or HES with or without CRYSs (HES group, n = 86) for at least 24 hours. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Creatinine concentrations at admission to the intensive care unit (T0), and 2-13 days (T1) and 2-12 weeks (T2) after initiation of fluid therapy were analyzed. Creatinine concentrations were analyzed as absolute values and as the maximum percentage change from T0 to T1 (T1max%) and from T0 to T2 (T2max%), respectively. Creatinine concentrations were available for 192 dogs during T1 and 37 dogs during T2. The median cumulative dose of HES was 86 mL/kg (range, 12-336 mL/kg). No difference was detected between the groups for age, gender, body weight, and length of hospitalization. Outcome was significantly different between the HES (66% survived) and the CRYS (87% survived) groups (P = 0.014). No significant difference was detected between groups for creatinine concentrations at T0, T1, T2, T1max%, or T2max%. No significant difference was detected between the groups for T1max% creatinine in dogs subclassified as having systemic inflammatory response syndrome or sepsis. CONCLUSIONS HES administration in this canine population did not result in increased creatinine concentrations compared to administration of CRYSs. Further studies are needed to establish the safety of HES in critically ill dogs.