11 resultados para 1341
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Vertebroplasty and kyphoplasty are well-established minimally invasive treatment options for compression fractures of osteoporotic vertebral bodies. Possible procedural disadvantages, however, include incomplete fracture reduction or a significant loss of reduction after balloon tamp deflation, prior to cement injection. A new procedure called "vertebral body stenting" (VBS) was tested in vitro and compared to kyphoplasty. VBS uses a specially designed catheter-mounted stent which can be implanted and expanded inside the vertebral body. As much as 24 fresh frozen human cadaveric vertebral bodies (T11-L5) were utilized. After creating typical compression fractures, the vertebral bodies were reduced by kyphoplasty (n = 12) or by VBS (n = 12) and then stabilized with PMMA bone cement. Each step of the procedure was performed under fluoroscopic control and analysed quantitatively. Finally, static and dynamic biomechanical tests were performed. A complete initial reduction of the fractured vertebral body height was achieved by both systems. There was a significant loss of reduction after balloon deflation in kyphoplasty compared to VBS, and a significant total height gain by VBS (mean +/- SD in %, p < 0.05, demonstrated by: anterior height loss after deflation in relation to preoperative height [kyphoplasty: 11.7 +/- 6.2; VBS: 3.7 +/- 3.8], and total anterior height gain [kyphoplasty: 8.0 +/- 9.4; VBS: 13.3 +/- 7.6]). Biomechanical tests showed no significant stiffness and failure load differences between systems. VBS is an innovative technique which allows for the possibly complete reduction of vertebral compression fractures and helps maintain the restored height by means of a stent. The height loss after balloon deflation is significantly decreased by using VBS compared to kyphoplasty, thus offering a new promising option for vertebral augmentation.
A prospective study of the impact of air pollution on respiratory symptoms and infections in infants
Resumo:
Rationale: There is increasing evidence that short-term exposure to air pollution has a detrimental effect on respiratory health, but data from healthy populations, particularly infants, are scarce. Objectives: To assess the association of air pollution with frequency and severity of respiratory symptoms and infections measured weekly in healthy infants. Methods: In a prospective birth cohort of 366 infants of unselected mothers, respiratory health was assessed weekly by telephone interviews during the first year of life (19,106 total observations). Daily mean levels of particulate matter (PM10), nitrogen dioxide (NO2), and ozone (O3) were obtained from local monitoring stations. We determined the association of the preceding week's pollutant levels with symptom scores and respiratory tract infections using a generalized additive mixed model with an autoregressive component. In addition, we assessed whether neonatal lung function influences this association and whether duration of infectious episodes differed between weeks with normal PM10 and weeks with elevated levels. Measurements and Main Results: We found a significant association between air pollution and respiratory symptoms, particularly in the week after respiratory tract infections (risk ratio, 1.13 [1.02-1.24] per 10 μg/m(3) PM10 levels) and in infants with premorbid lung function. During times of elevated PM10 (>33.3 μg/m(3)), duration of respiratory tract infections increased by 20% (95% confidence interval, 2-42%). Conclusions: Exposure to even moderate levels of air pollution was associated with increased respiratory symptoms in healthy infants. Particularly in infants with premorbid lung function and inflammation, air pollution contributed to longer duration of infectious episodes with a potentially large socioeconomic impact.
Resumo:
The initital purpose for developing artificial oxygen carriers was to replace blood transfusions in order to avoid their adverse effects such as immunologic reactions, transmission of infectious diseases, limited availability and restricted storage conditions. With the advent of new generations of artifical oxygen carriers, a shift of paradigm evolved that considers the artificial oxygen carriers as oxygen therapeutics re-distributing oxygen delivery in the favor of tissues in need. This function may find a particular application in tissues rendered hypoxic due to arterial occlusive diseases. This review, based on a large series of intravital microscopy studies in a hamster skin flap model, outlines the optimal design of hemoglobin vesicles?HbVs?given for the above intention. In summary, the HbV should be of a large diameter, and oxygen affinity, colloid osmotic pressure and viscosity of the HbV solution should be high.
Resumo:
OBJECTIVE: To investigate the ability of delayed gadolinium-enhanced magnetic resonance (MR) imaging of cartilage (dGEMRIC) and T2 mapping to evaluate the quality of repair tissue after microfracture. DESIGN: Twelve knees from 12 goats were studied. An osteochondral defect (diameter, 6mm; depth, 3mm) with microfracture was created in the weight-bearing aspect of both the medial and lateral femoral condyles. Goats were euthanized at 24 weeks (n=6) and 48 weeks (n=6) postsurgery. Pre-contrast R1 (R1pre) and post-contrast R1 (R1post) measurements for dGEMRIC and a pre-contrast T2 measurement for T2 mapping were performed with a 3T MR imaging system. MR imaging findings were compared with histological and biochemical assessments. RESULTS: In native cartilage, significant correlations were observed between the R1post and the glycosaminoglycan (GAG) concentration, as well as DeltaR1 (difference between the R1pre and R1post) and the GAG concentration (P<0.05). In repair tissue, a significant correlation was observed between DeltaR1 and the GAG concentration (P<0.05), but not between the R1post and the GAG concentration. In both repair tissue and native cartilage, no correlation was observed between T2 and the water concentration or between T2 and the hydroxyproline (HP) concentration. A zonal variation of T2 and a clear dependence of T2 on the angles relative to B0 were observed in native cartilage, but not in repair tissue. CONCLUSION: dGEMRIC with DeltaR1 measurement might be useful for the evaluation of the GAG concentration in repair tissue after microfracture. T2 mapping might be useful for the differentiation of repair tissue after microfracture from native cartilage; however, its potential to assess the specific biochemical markers in native cartilage as well as repair tissue may be limited.
Resumo:
In order to harness the unique properties of nanoparticles for novel clinical applications and to modulate their uptake into specific immune cells we designed a new library of homo- and hetero-functional fluorescence-encoded gold nanoparticles (Au-NPs) using different poly(vinyl alcohol) and poly(ethylene glycol)-based polymers for particle coating and stabilization. The encoded particles were fully characterized by UV-Vis and fluorescence spectroscopy, zeta potential and dynamic light scattering. The uptake by human monocyte derived dendritic cells in vitro was studied by confocal laser scanning microscopy and quantified by fluorescence-activated cell sorting and inductively coupled plasma atomic emission spectroscopy. We show how the chemical modification of particle surfaces, for instance by attaching fluorescent dyes, can conceal fundamental particle properties and modulate cellular uptake. In order to mask the influence of fluorescent dyes on cellular uptake while still exploiting its fluorescence for detection, we have created hetero-functionalized Au-NPs, which again show typical particle dependent cellular interactions. Our study clearly prove that the thorough characterization of nanoparticles at each modification step in the engineering process is absolutely essential and that it can be necessary to make substantial adjustments of the particles in order to obtain reliable cellular uptake data, which truly reflects particle properties.
Resumo:
While there is currently burgeoning interest in the application of the CRISPR/Cas (clustered regularly interspaced short palindromic repeats/CRISPR-associated genes) to genome editing, it is perhaps not widely appreciated that this is the second discovery of a small RNA (sRNA)-targeted DNA-deletion system. The first sRNA-targeted DNA-deletion system to be discovered, which we call IES/Ias (internal eliminated sequence/IES-associated genes) to contrast with CRISPR/Cas, is found in ciliates, and, like CRISPR/Cas, is thought to serve as a form of immune defense against invasive DNAs. The manner in which the ciliate IES/Ias system functions is distinct from that of the CRISPR/Cas system in archaea and bacteria, and arose independently through a synthesis of RNA interference-derived and DNA-specific molecular components. Despite the major differences between CRISPR/Cas and IES/Ias, both systems face similar conceptual challenges in targeting invasive DNAs. In this review, we focus on the discovery, effects, function, and evolutionary consequences of the IES/Ias system.
Resumo:
BACKGROUND We previously reported the 5-year followup of hips with femoroacetabular impingement (FAI) that underwent surgical hip dislocation with trimming of the head-neck junction and/or acetabulum including reattachment of the labrum. The goal of this study was to report a concise followup of these patients at a minimum 10 years. QUESTIONS/PURPOSES We asked if these patients had (1) improved hip pain and function; we then determined (2) the 10-year survival rate and (3) calculated factors predicting failure. METHODS Between July 2001 and March 2003, we performed surgical hip dislocation and femoral neck osteoplasty and/or acetabular rim trimming with labral reattachment in 75 patients (97 hips). Of those, 72 patients (93 hips [96%]) were available for followup at a minimum of 10 years (mean, 11 years; range, 10-13 years). We used the anterior impingement test to assess pain and the Merle d'Aubigné-Postel score to assess function. Survivorship calculation was performed using the method of Kaplan and Meier and any of the following factors as a definition of failure: conversion to total hip arthroplasty (THA), radiographic evidence of worsening osteoarthritis (OA), or a Merle d'Aubigné-Postel score less than 15. Predictive factors for any of these failures were calculated using the Cox regression analysis. RESULTS At 10-year followup, the prevalence of a positive impingement test decreased from preoperative 95% to 38% (p < 0.001) and the Merle d'Aubigné-Postel score increased from preoperative 15.3 ± 1.4 (range, 9-17) to 16.9 ± 1.3 (12-18; p < 0.001). Survivorship of these procedures for any of the defined failures was 80% (95% confidence interval, 72%-88%). The strongest predictors of failure were age > 40 years (hazard ratio with 95% confidence interval, 5.9 [4.8-7.1], p = 0.002), body mass index > 30 kg/m(2) (5.5 [3.9-7.2], p = 0.041), a lateral center-edge angle < 22° or > 32° (5.4 [4.2-6.6], p = 0.006), and a posterior acetabular coverage < 34% (4.8 [3.7-5.6], p = 0.006). CONCLUSIONS At 10-year followup, 80% of patients with FAI treated with surgical hip dislocation, osteoplasty, and labral reattachment had not progressed to THA, developed worsening OA, or had a Merle d'Aubigné-Postel score of less than 15. Radiographic predictors for failure were related to over- and undertreatment of acetabular rim trimming.
Resumo:
PURPOSE To assess whether reaction time (RT) and movement time (MT), as the two components of the total brake response time (TBRT) and brake force (BF) are different in patients with a foot joint arthrodesis in comparison to controls. METHODS The study was a comparative case series in a driving simulator under realistic driving conditions. Mobile patients without a walker, ≥6 months after surgery who were driving a car and had no neurological co-morbidity, knee or hip joint prosthesis were included in the study. The selection criteria resulted in 12 patients with right tibiotalar joint arthrodesis (TTJA) and 12 patients with another right foot joint arthrodesis (OFJA), who were compared to 17 individuals without any ankle-joint pathology. For TBRT, an empirical safe driving threshold of 700 ms was used. The outcome measures were RT, MT, TBRT, BF and McGuire score. RESULTS MT (p = 0.034) and TBRT (p = 0.026) were longer in TTJA patients in comparison with the controls. Also, more patients with TTJA than patients with OFJA and controls exceeded the safe driving threshold (p = 0.028). The outcomes in OFJA patients and in controls were comparable. The McGuire score was similar between the TTJA and OFJA patients (p = 0.26). CONCLUSIONS Significantly slower MT and TBRT, and significantly more patients exceeding the safe driving threshold, were observed after a tibiotalar-joint arthrodesis in comparison to the controls. Patients with OFJAs were not significantly different from the controls. Driving and emergency braking may be impaired after tibiotalar-joint arthrodesis.