58 resultados para 120301 Design History and Theory
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.
Resumo:
The surgical treatment of liver tumours relies on precise localization of the lesions and detailed knowledge of the patient-specific vascular and biliary anatomy. Detailed three-dimensional (3D) anatomical information facilitates complete tumour removal while preserving a sufficient amount of functional liver tissue.
Resumo:
Exposure to farming environments has been shown to protect substantially against asthma and atopic disease across Europe and in other parts of the world. The GABRIEL Advanced Surveys (GABRIELA) were conducted to determine factors in farming environments which are fundamental to protecting against asthma and atopic disease. The GABRIEL Advanced Surveys have a multi-phase stratified design. In a first-screening phase, a comprehensive population-based survey was conducted to assess the prevalence of exposure to farming environments and of asthma and atopic diseases (n = 103,219). The second phase was designed to ascertain detailed exposure to farming environments and to collect biomaterial and environmental samples in a stratified random sample of phase 1 participants (n = 15,255). A third phase was carried out in a further stratified sample only in Bavaria, southern Germany, aiming at in-depth respiratory disease and exposure assessment including extensive environmental sampling (n = 895). Participation rates in phase 1 were around 60% but only about half of the participating study population consented to further study modules in phase 2. We found that consenting behaviour was related to familial allergies, high parental education, wheeze, doctor diagnosed asthma and rhinoconjunctivitis, and to a lesser extent to exposure to farming environments. The association of exposure to farm environments with asthma or rhinoconjunctivitis was not biased by participation or consenting behaviour. The GABRIEL Advanced Surveys are one of the largest studies to shed light on the protective 'farm effect' on asthma and atopic disease. Bias with regard to the main study question was able to be ruled out by representativeness and high participation rates in phases 2 and 3. The GABRIEL Advanced Surveys have created extensive collections of questionnaire data, biomaterial and environmental samples promising new insights into this area of research.
Conceptual Design, Neutronic and Radioprotection Study of a Fast Neutron Irradiation Station at SINQ
Resumo:
A genomic biomarker identifying patients likely to benefit from drotrecogin alfa (activated) (DAA) may be clinically useful as a companion diagnostic. This trial was designed to validate biomarkers (improved response polymorphisms (IRPs)). Each IRP (A and B) contains two single nucleotide polymorphisms that were associated with a differential DAA treatment effect.
Resumo:
The design of a high-density neural recording system targeting epilepsy monitoring is presented. Circuit challenges and techniques are discussed to optimize the amplifier topology and the included OTA. A new platform supporting active recording devices targeting wireless and high-resolution focus localization in epilepsy diagnosis is also proposed. The post-layout simulation results of an amplifier dedicated to this application are presented. The amplifier is designed in a UMC 0.18µm CMOS technology, has an NEF of 2.19 and occupies a silicon area of 0.038 mm(2), while consuming 5.8 µW from a 1.8-V supply.