8 resultados para 0-200 m

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives To examine gender differences along the care pathway to total hip replacement. Methods We conducted a population-based cross-sectional study of 26,046 individuals aged 35 years and over in Avon and Somerset. Participants completed a questionnaire asking about care provision at five milestones on the pathway to total hip replacement. Those reporting hip disease were invited to a clinical examination. We estimated odds ratios (ORs) [95% confidence intervals (CI)] for provision of care to women compared with men. Results 3169 people reported hip pain, 2018 were invited for clinical examination, and 1405 attended (69.6%). After adjustment for age and disease severity, women were less likely than men to have consulted their general practitioner (OR 0.78, 95%-CI 0.61–1.00), as likely as men to have received drug therapy for hip pain in the previous year (OR 0.96, 95%-CI 0.74–1.24), but less likely to have been referred to specialist care (OR 0.53, 95%-CI 0.40–0.70), to have consulted an orthopaedic surgeon (OR 0.50, 95%-CI 0.32–0.78), or to be on a waiting list for total hip replacement (OR 0.41, 95%-CI 0.20–0.87). Differences remained in the 746 people who had sought care from their general practitioner, and after adjustment for willingness and fitness for surgery. Conclusions There are gender inequalities in provision of care for hip disease in England, which are not fully accounted for by gender differences in care seeking and treatment preferences. Differences in referral to specialist care by general practitioners might unwittingly contribute to this inequity. Accurate information about availability, benefits and risks of hip replacement for providers and patients, and continuing education to ensure that clinicians interpret and correct patients' assumptions could help reduce inequalities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electronic structure of atomically precise armchair graphene nanoribbons of width N=7 (7-AGNRs) are investigated by scanning tunneling spectroscopy (STS) on Au(111). We record the standing waves in the local density of states of finite ribbons as a function of sample bias and extract the dispersion relation of frontier electronic states by Fourier transformation. The wave-vector-dependent contributions from these states agree with density functional theory calculations, thus enabling the unambiguous assignment of the states to the valence band, the conduction band, and the next empty band with effective masses of 0.41±0.08me,0.40±0.18me, and 0.20±0.03me, respectively. By comparing the extracted dispersion relation for the conduction band to corresponding height-dependent tunneling spectra, we find that the conduction band edge can be resolved only at small tip-sample separations and has not been observed before. As a result, we report a band gap of 2.37±0.06 eV for 7-AGNRs adsorbed on Au(111).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Solar nebula processes led to a depletion of volatile elements in different chondrite groups when compared to the bulk chemical composition of the solar system deduced from the Sun's photosphere. For moderately-volatile elements, this depletion primarily correlates with the element condensation temperature and is possibly caused by incomplete condensation from a hot solar nebula, evaporative loss from the precursor dust, and/or inherited from the interstellar medium. Element concentrations and interelement ratios of volatile elements do not provide a clear picture about responsible mechanisms. Here, the abundance and stable isotope composition of the moderately- to highly-volatile element Se are investigated in carbonaceous, ordinary, and enstatite chondrites to constrain the mechanism responsible for the depletion of volatile elements in planetary bodies of the inner solar system and to define a δ(82/78)Se value for the bulk solar system. The δ(82/78)Se of the studied chondrite falls are identical within their measurement uncertainties with a mean of −0.20±0.26‰ (2 s.d., n=14n=14, relative to NIST SRM 3149) despite Se abundance depletions of up to a factor of 2.5 with respect to the CI group. The absence of resolvable Se isotope fractionation rules out a kinetic Rayleigh-type incomplete condensation of Se from the hot solar nebula or partial kinetic evaporative loss on the precursor material and/or the parent bodies. The Se depletion, if acquired during partial condensation or evaporative loss, therefore must have occurred under near equilibrium conditions to prevent measurable isotope fractionation. Alternatively, the depletion and cooling of the nebula could have occurred simultaneously due to the continuous removal of gas and fine particles by the solar wind accompanied by the quantitative condensation of elements from the pre-depleted gas. In this scenario the condensation of elements does not require equilibrium conditions to avoid isotope fractionation. The results further suggest that the processes causing the high variability of Se concentrations and depletions in ordinary and enstatite chondrites did not involve any measurable isotope fractionation. Different degrees of element depletions and isotope fractionations of the moderately-volatile elements Zn, S, and Se in ordinary and enstatite chondrites indicate that their volatility is controlled by the thermal stabilities of their host phases and not by the condensation temperature under canonical nebular conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 mu A C- out of gaseous samples with an efficiency of 3-6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3-30 mu g carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of C-14/C-12 could be repeated within statistical errors to better than 1.0% and the C-13/C-12 ratios to better than 0.2%. The blank was < 1 pMC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the impact of stratospheric volcanic aerosols on the diurnal temperature range (DTR) over Europe using long-term subdaily station records. We compare the results with a 28-member ensemble of European Centre/Hamburg version 5.4 (ECHAM5.4) general circulation model simulations. Eight stratospheric volcanic eruptions during the instrumental period are investigated. Seasonal all- and clear-sky DTR anomalies are compared with contemporary (approximately 20 year) reference periods. Clear sky is used to eliminate cloud effects and better estimate the signal from the direct radiative forcing of the volcanic aerosols. We do not find a consistent effect of stratospheric aerosols on all-sky DTR. For clear skies, we find average DTR anomalies of −0.08°C (−0.13°C) in the observations (in the model), with the largest effect in the second winter after the eruption. Although the clear-sky DTR anomalies from different stations, volcanic eruptions, and seasons show heterogeneous signals in terms of order of magnitude and sign, the significantly negative DTR anomalies (e.g., after the Tambora eruption) are qualitatively consistent with other studies. Referencing with clear-sky DTR anomalies to the radiative forcing from stratospheric volcanic eruptions, we find the resulting sensitivity to be of the same order of magnitude as previously published estimates for tropospheric aerosols during the so-called “global dimming” period (i.e., 1950s to 1980s). Analyzing cloud cover changes after volcanic eruptions reveals an increase in clear-sky days in both data sets. Quantifying the impact of stratospheric volcanic eruptions on clear-sky DTR over Europe provides valuable information for the study of the radiative effect of stratospheric aerosols and for geo-engineering purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Few studies consider the incidence of individual AIDS-defining illnesses (ADIs) at higher CD4 counts, relevant on a population level for monitoring and resource allocation. Methods. Individuals from the Collaboration of Observational HIV Epidemiological Research Europe (COHERE) aged ≥14 years with ≥1 CD4 count of ≥200 µL between 1998 and 2010 were included. Incidence rates (per 1000 person-years of follow-up [PYFU]) were calculated for each ADI within different CD4 strata; Poisson regression, using generalized estimating equations and robust standard errors, was used to model rates of ADIs with current CD4 ≥500/µL. Results. A total of 12 135 ADIs occurred at a CD4 count of ≥200 cells/µL among 207 539 persons with 1 154 803 PYFU. Incidence rates declined from 20.5 per 1000 PYFU (95% confidence interval [CI], 20.0–21.1 per 1000 PYFU) with current CD4 200–349 cells/µL to 4.1 per 1000 PYFU (95% CI, 3.6–4.6 per 1000 PYFU) with current CD4 ≥ 1000 cells/µL. Persons with a current CD4 of 500–749 cells/µL had a significantly higher rate of ADIs (adjusted incidence rate ratio [aIRR], 1.20; 95% CI, 1.10–1.32), whereas those with a current CD4 of ≥1000 cells/µL had a similar rate (aIRR, 0.92; 95% CI, .79–1.07), compared to a current CD4 of 750–999 cells/µL. Results were consistent in persons with high or low viral load. Findings were stronger for malignant ADIs (aIRR, 1.52; 95% CI, 1.25–1.86) than for nonmalignant ADIs (aIRR, 1.12; 95% CI, 1.01–1.25), comparing persons with a current CD4 of 500–749 cells/µL to 750–999 cells/µL. Discussion. The incidence of ADIs was higher in individuals with a current CD4 count of 500–749 cells/µL compared to those with a CD4 count of 750–999 cells/µL, but did not decrease further at higher CD4 counts. Results were similar in patients virologically suppressed on combination antiretroviral therapy, suggesting that immune reconstitution is not complete until the CD4 increases to >750 cells/µL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sediment cores spanning the last two centuries were taken in Hagelseewli, a high-elevation lake in the Swiss Alps. Contiguous 0.5 cm samples were analysed for biological remains, including diatoms, chironomids, cladocera, chrysophyte cysts, and fossil pigments. In addition, sedimentological and geochemical variables such as loss-on-ignition, total carbon, nitrogen, sulphur, grain-size and magnetic mineralogy were determined. The results of these analyses were compared to a long instrumental air temperature record that was adapted to the elevation of Hagelseewli by applying mean monthly lapse rates. During much of the time, the lake is in the shadow of a high cliff to the south, so that the lake is ice-covered during much of the year and thus decoupled from climatic forcing. Lake biology is therefore influenced more by the duration of ice-cover than by direct temperature effects during the short open-water season. Long periods of ice-cover result in anoxic water conditions and dissolution of authigenic calcites, leading to carbonate-free sediments. The diversity of chironomid and cladoceran assemblages is extremely low, whereas that of diatom and chrysophyte cyst assemblages is much higher. Weak correlations were observed between the diatom and chrysophyte cyst assemblages on the one hand and summer or autumn air temperatures on the other, but the proportion of variance explained is low, so that air temperature alone cannot account for the degree of variation observed in the paleolimnological record. Analyses of mineral magnetic parameters, spheroidal carbonaceous particles and lead suggest that atmospheric pollution has had a significant effect on the sediments of Hagelseewli, but little effect on the water quality as reflected in the lake biota.