43 resultados para Échocardiographie Doppler

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. Its practical determination by echocardiography remains challenging. We compared routine assessment of lateral tricuspid annular systolic motion velocity (TV(lat), cm/s) using pulsed-wave tissue Doppler imaging from the apical 4-chamber view with cardiac magnetic resonance (CMR) as reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rhythm analysis of the fetal heart is hampered by the inability to routinely obtain electrocardiographic recordings of the fetus. Doppler studies of fetal cardiac tissue movements, assessing cardiac movements both qualitatively and quantitatively, have recently been described. We used a conventional high-resolution ultrasound system to obtain rhythm data from pulsed-wave tissue Doppler signals of the fetal heart in normal cardiac rhythm and in a variety of fetal cardiac arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess influence of durotomy on spinal cord blood flow (SCBF) in chondrodystrophic dogs with thoracolumbar disk extrusion. STUDY DESIGN: Prospective cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n = 11). METHODS: Diagnosis was based on neurologic signs, magnetic resonance imaging (MRI) findings, and surgical confirmation. Regional SCBF was measured 3 times intraoperatively by laser-Doppler flowmetry: (1) before surgical decompression; (2) immediately after decompression by hemilaminectomy-durotomy; and (3) after 15 minutes of lesion lavage. A standardized hemilaminectomy and durotomy performed by the same neurosurgeon, was used to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found immediately after spinal cord decompression and durotomy in dogs but SCBF returned to previous levels or lower after 15 minutes of lavage. Changes in SCBF were not associated with duration of clinical signs; neurologic status, degree of spinal cord compression, or signal intensity changes as assessed by MRI. CONCLUSION: Durotomy does not increase SCBF in dogs with disk extrusion associated spinal cord compression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thiel-embalmed human whole head specimens represent an alternative model in middle ear research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the wind radiometer WIRA, a new ground-based microwave Doppler-spectro-radiometer specifically designed for the measurement of middle-atmospheric horizontal wind by observing ozone emission spectra at 142.17504 GHz. Currently, wind speeds in five levels between 30 and 79 km can be retrieved which makes WIRA the first instrument able to continuously measure horizontal wind in this altitude range. For an integration time of one day the measurement error on each level lies at around 25 m s−1. With a planned upgrade this value is expected to be reduced by a factor of 2 in the near future. On the altitude levels where our measurement can be compared to wind data from the European Centre for Medium-Range Weather Forecasts (ECMWF) very good agreement in the long-term statistics as well as in short time structures with a duration of a few days has been found. WIRA uses a passive double sideband heterodyne receiver together with a digital Fourier transform spectrometer for the data acquisition. A big advantage of the radiometric approach is that such instruments can also operate under adverse weather conditions and thus provide a continuous time series for the given location. The optics enables the instrument to scan a wide range of azimuth angles including the directions east, west, north, and south for zonal and meridional wind measurements. The design of the radiometer is fairly compact and its calibration does not rely on liquid nitrogen which makes it transportable and suitable for campaign use. WIRA is conceived in a way that it can be operated remotely and does hardly require any maintenance. In the present paper, a description of the instrument is given, and the techniques used for the wind retrieval based on the determination of the Doppler shift of the measured atmospheric ozone emission spectra are outlined. Their reliability was tested using Monte Carlo simulations. Finally, a time series of 11 months of zonal wind measurements over Bern (46°57′ N, 7°26′ E) is presented and compared to ECMWF wind data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the pulp sensitivity and vitality of mandibular incisors and canines before and after bone harvesting in the symphysis. MATERIALS AND METHODS: In 20 patients requiring bone grafts from the symphysis, pulp sensitivity (carbon dioxide [CO2]) and pulpal blood flow (laser Doppler flowmetry [LDF]) of mandibular incisors and canines were evaluated preoperatively, postoperatively, and 6 months after surgery. Teeth were allocated to 1 of 3 groups according to their initial and final reaction to CO2 (group A = teeth with a positive reaction throughout the study, group B = teeth that exhibited a sensitivity change from positive to negative, and group C = teeth with a negative reaction throughout the study). RESULTS: Preoperative flux measurements (LDF) did not differ between groups A, B, and C. Teeth with sensitivity changes (group B) showed the greatest decrease (a statistically significant decrease) of pulpal blood flow over time, whereas teeth in groups A and C demonstrated an insignificant reduction of flux over time. DISCUSSION AND CONCLUSIONS: LDF was purely used as an experimental tool in the present study. Pulpal blood flow measurements using LDF demonstrated a decrease of flux over time in anterior mandibular teeth following bone harvesting in the symphysis. A significant change of flux, however, was only observed for teeth that also demonstrated a loss of pulp sensitivity during the same study period. Loss of pulp sensitivity appeared to be correlated to a significant decrease of blood flow assessed by LDF.