11 resultados para Äiti (televisio-ohjelma)
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.
Resumo:
PURPOSE: The purpose of this prospective study on humans were to evaluate (a) the clinical outcome of alveolar distraction osteogenesis for the correction of vertically deficient edentulous mandibular ridges, (b) the clinical outcome of dental implants placed in the distracted areas, and (c) the quality and quantity of the bone that had formed in the distraction gap. MATERIAL AND METHODS: Seven patients presenting vertically deficient edentulous ridges were treated by means of distraction osteogenesis with an intraoral alveolar distractor. Approximately 3 months after consolidation of the distracted segments, 20 ITI solid screw SLA implants were placed in the distracted areas. Three to 4 months later, abutments were connected and prosthetic loading of the implants started. During implant site preparation, bone biopsies were taken at the implant sites with trephine burrs for histologic and histometric analyses. RESULTS: The mean follow-up after the initial prosthetic loading was 18 months (range 12-24 months). The mean bone gain obtained at the end of distraction was 7 mm (range 5-9 mm). The cumulative success rate of implants 2 years after the onset of prosthetic loading was 95%, whereas the survival rate of implants was 100%. The newly formed bone consisted of woven bone reinforced by parallel-fibered bone with bone marrow spaces between the bone trabeculae. The bone area fraction in the distraction region ranged from 21.6% to 57.8% (38.5+/-11.7%). DISCUSSION AND CONCLUSIONS: Results from this study showed that (a) distraction osteogenesis is a reliable technique for the correction of vertically deficient edentulous ridges, (b) the regenerated bone withstood the functional demands of implant loading, (c) survival and success rates of implants placed in the distracted areas were consistent with those of implants placed in native bone, and (d) there is sufficient bone volume and maturity in the distracted region for primary stability of the implant.
Resumo:
OBJECTIVES: This experiment was performed to evaluate clinically and histologically the effect of mechanical therapy with or without antiseptic therapy on peri-implant mucositis lesions in nine cynomolgus monkeys. MATERIAL AND METHODS: Two ITI titanium implants were inserted into each side of the mandibles. After 90 days of plaque control and soft tissue healing, a baseline clinical examination was completed. Peri-implant lesions were induced by placing silk ligatures and allowing plaque to accumulate for 6 weeks. The clinical examination was then repeated, and the monkeys were randomly assigned to three treatment groups: group A, mechanical cleansing only; group B, mechanical cleansing and local irrigation with 0.12% chlorhexidine (CHX) and application of 0.2% CHX gel; and group C, control, no treatment. The implants in treatment groups A and B were treated and maintained according to the assigned treatment for two additional months. At the end of the maintenance period, a final clinical examination was performed and the animals were sacrificed for biopsies. RESULTS: The mean probing depths (PD) values at mucositis were: 3.5, 3.7, and 3.4 mm, and clinical attachment level (CAL) = 3.8, 4.1, and 3.9 mm for treatment groups A, B and C, respectively. The corresponding values after treatment were: PD = 1.7, 2.1, and 2.5 mm, and CAL=2.6, 2.6, and 3.1 mm. ANOVA of mean changes (Delta) in PD and CAL after treatment showed no statistical difference between the treatment groups. Comparison of the mean changes in PD and CAL after treatment yielded statistical differences between the control and treatment groups P < 0.01. According to the t-test, no statistical difference was found between treatment groups A and B for the PD reduction but there was a significant difference for the CAL change, P < 0.03. Group A had significantly more recession and less CAL gain than group B. Non-parametric tests yielded no significant differences in modified plaque index (mPlI) and gingival index (GI) after treatment between both treatment groups. Frequencies and percent distributions of the mPlI and GI scores changed considerably for both treatment groups when compared with the changes in the control group after treatment. With regard to the histological evaluation, no statistical differences existed between the treatments for any linear measurement. The proportion of inflammation found in the mucosal tissues of the control implants was greater than the one found for both treatment groups, P < 0.01. More importantly, both treatment groups showed a similar low proportion of inflammation after 2 months of treatment. CONCLUSIONS: Within the limitations of this experiment, and considering the supportive plaque control rendered, it can be concluded that for pockets of 3-4 mm: (1) mechanical therapy alone or combined with CHX results in the clinical resolution of peri-implant mucositis lesions, (2) histologically, both treatments result in minimal inflammation compatible with health, and (3) the mechanical effect alone is sufficient to achieve clinical and histologic resolution of mucositis lesions.
Resumo:
AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.
Achieving optimal esthetic results: Surgical considerations with regard to single-tooth replacements
Resumo:
PURPOSE: The objective of the present experiment was to study the morphogenesis of the mucosal attachment to implants made of c.p. titanium. MATERIAL AND METHODS: All mandibular premolars were extracted in 20 Labrador dogs. After a healing period of 3 months, four implants (ITI Dental Implant System) were placed in the right and left sides of the mandible. A non-submerged implant installation technique was used and the mucosal tissues were secured to the conical marginal portion of the implants with interrupted sutures. The sutures were removed after 2 weeks and a plaque control program including daily cleaning of the remaining teeth and the implants was initiated. The animals were sacrificed and biopsies were obtained at various intervals to provide healing periods extending from Day 0 (2 h) to 12 weeks. The mandibles were removed and placed in the fixative. The implant sites were dissected using a diamond saw and processed for histological analysis. RESULTS: Large numbers of neutrophils infiltrated and degraded the coagulum that occupied the compartment between the mucosa and the implant during the initial phase of healing. At 2 weeks after surgery, fibroblasts were the dominating cell population in the connective tissue interface but at 4 weeks the density of fibroblasts had decreased. Furthermore, the first signs of epithelial proliferation were observed in specimens representing 1-2 weeks of healing and a mature barrier epithelium occurred after 6-8 weeks of healing. The collagen fibers of the mucosa were organized after 4-6 weeks of healing. CONCLUSION: It is suggested that the soft-tissue attachment to implants placed using a non-submerged installation procedure is properly established after several weeks following surgery.
Resumo:
The purpose of this study was to investigate the generality and temporal endurance of the bivalency effect in task switching. This effect refers to the slowing on univalent stimuli that occurs when bivalent stimuli appear occasionally. We used a paradigm involving predictable switches between 3 simple tasks, with bivalent stimuli occasionally occurring on one of the tasks. The generality of the bivalency effect was investigated by using different tasks and different types of bivalent stimuli, and the endurance of this effect was investigated across different intertrial intervals (ITIs) and across the univalent trials that followed trials with bivalent stimuli. In 3 experiments, the results showed a general, robust, and enduring bivalency effect for all ITI conditions. Although the effect declined across trials, it remained significant for about 4 trials following one with a bivalent stimulus. Our findings emphasise the importance of top–down processes in task-switching performance. (PsycINFO Database Record (c) 2012 APA, all rights reserved)