285 resultados para ultrasound guided nerveblock
Resumo:
The aims of this prospective observational study were to assess the incidence of intraconal spread during peribulbar (extraconal) anesthesia by real-time ultrasound imaging of the retro-orbital compartment and to determine whether a complete sensory and motor block (with akinesia) of the eye is directly related to the intraconal spread.
Resumo:
Background. Transvaginal ultrasound (TVU) in female patients with acute right lower quadrant (RLQ) abdominal pain is time and infrastructure intensive and not always available. This study aims to evaluate the role of TVU in these patients. Methods. Retrospective analysis identified 224 female patients with RLQ pain and TVU. Results. TVU revealed an underlying pathology in 34 (15%) patients, necessitating a diagnostic laparoscopy in 12 patients. Six patients (2%) had a true gynaecological emergency. The remaining 23 patients did not require surgery. The other 190 patients with RLQ pain had a bland TVU; 127 (67%) were discharged, while 63 patients (33%) received a diagnostic laparoscopy. Conclusion. The incidence of true gynaecological emergencies requiring urgent surgical intervention is very low in our patient cohort. TVU is a helpful tool if performed by a physician who is well trained in TVU.
Resumo:
The preferred initial treatment for patients with stable coronary artery disease is the best available medical therapy. We hypothesized that in patients with functionally significant stenoses, as determined by measurement of fractional flow reserve (FFR), percutaneous coronary intervention (PCI) plus the best available medical therapy would be superior to the best available medical therapy alone.
Resumo:
Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.
Resumo:
To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.
Resumo:
This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.
Resumo:
Ultrasound detection of sub-clinical atherosclerosis (ATS) may help identify individuals at high cardiovascular risk. Most studies evaluated intima-media thickness (IMT) at carotid level. We compared the relationships between main cardiovascular risk factors (CVRF) and five indicators of ATS (IMT, mean and maximal plaque thickness, mean and maximal plaque area) at both carotid and femoral levels. Ultrasound was performed on 496 participants aged 45-64 years randomly selected from the general population of the Republic of Seychelles. 73.4 % participants had ≥ 1 plaque (IMT thickening ≥ 1.2 mm) at carotid level and 67.5 % at femoral level. Variance (adjusted R2) contributed by age, sex and CVRF (smoking, LDL-cholesterol, HDL-cholesterol, blood pressure, diabetes) in predicting any of the ATS markers was larger at femoral than carotid level. At both carotid and femoral levels, the association between CVRF and ATS was stronger based on plaque-based markers than IMT. Our findings show that the associations between CVRF and ATS markers were stronger at femoral than carotid level, and with plaque-based markers rather than IMT. Pending comparison of these markers using harder cardiovascular endpoints, our findings suggest that markers based on plaque morphology assessed at femoral artery level might be useful cardiovascular risk predictors.
Resumo:
BACKGROUND: Stopping antiretroviral therapy in patients with HIV-1 infection can reduce costs and side-effects, but carries the risk of increased immune suppression and emergence of resistance. METHODS: 430 patients with CD4-positive T-lymphocyte (CD4) counts greater than 350 cells per muL, and viral load less than 50 copies per mL were randomised to continued therapy (n=146) or scheduled treatment interruptions (n=284). Median time on randomised treatment was 21.9 months (range 16.4-25.3). Primary endpoints were proportion of patients with viral load less than 50 copies per mL at the end of the trial, and amount of drugs used. Analysis was intention-to-treat. This study is registered at ClinicalTrials.gov with the identifier NCT00113126. FINDINGS: Drug savings in the scheduled treatment interruption group, compared with continuous treatment, amounted to 61.5%. 257 of 284 (90.5%) patients in the scheduled treatment interruption group reached a viral load less than 50 copies per mL, compared with 134 of 146 (91.8%) in the continued treatment group (difference 1.3%, 95% CI-4.3 to 6.9, p=0.90). No AIDS-defining events occurred. Diarrhoea and neuropathy were more frequent with continuous treatment; candidiasis was more frequent with scheduled treatment interruption. Ten patients (2.3%) had resistance mutations, with no significant differences between groups. INTERPRETATION: Drug savings with scheduled treatment interruption were substantial, and no evidence of increased treatment resistance emerged. Treatment-related adverse events were more frequent with continuous treatment, but low CD4 counts and minor manifestations of HIV infection were more frequent with scheduled treatment interruption.
Resumo:
A new image-guided microscope using augmented reality overlays has been developed. Unlike other systems, the novelty of our design consists in mounting a precise mini and low-cost tracker directly on the microscope to track the motion of the surgical tools and the patient. Correctly scaled cut-views of the pre-operative computed tomography (CT) stack can be displayed on the overlay, orthogonal to the optical view or even including the direction of a clinical tool. Moreover, the system can manage three-dimensional models for tumours or bone structures and allows interaction with them using virtual tools, showing trajectories and distances. The mean error of the overlay was 0.7 mm. Clinical accuracy has shown results of 1.1-1.8 mm.
Resumo:
The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.