178 resultados para balloon dilatation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Cardiac surgery is the reference treatment for patients with left main (LM) disease, although percutaneous coronary intervention with drug-eluting stents is emerging as a possible alternative. The objective of this registry was to evaluate the 2-year outcome of elective percutaneous coronary intervention for unprotected LM disease with paclitaxel-eluting stents. METHODS AND RESULTS: A total of 291 patients were prospectively included from 4 centers. Acute myocardial infarction and cardiogenic shock were the only exclusion criteria. Patients were 69+/-11 years old, 29% were diabetic, and 25% had 3-vessel disease. For distal LM lesions (78%), the provisional side-branch T-stenting approach was used in 92% of cases and final kissing balloon inflation in 97%. Angiographic success was obtained in 99.7% of cases. At 2-year follow-up, the total cardiac death rate was 5.4% (1 EuroSCORE point was associated with a 15% [95% confidence interval 2.9% to 28.2%, P=0.013] higher risk of cardiac death), target-lesion revascularization was 8.7%, and incidence of Q-wave or non-Q-wave myocardial infarction was 0.9% and 3.1%, respectively. The combined end point occurred in 15.8% of cases and stroke in 0.7%. The incidence of definite and probable LM stent thrombosis was 0.7%, whereas the incidence of any stent thrombosis was 3.8%, with a higher risk in patients with side-branch stenting in the presence of LM bifurcation lesions (hazard ratio 9.6, 95% confidence interval 1.2 to 77.7, P=0.035). CONCLUSIONS: Unprotected LM stenting with paclitaxel-eluting stents, with a strategy of provisional side-branch T-stenting for distal lesions, provides excellent acute angiographic results and good mid-term clinical outcomes, with a 15.8% rate of major adverse cardiac events at 2-year follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vertical profiles of stratospheric water vapour measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) with the full resolution mode between September 2002 and March 2004 and retrieved with the IMK/IAA scientific retrieval processor were compared to a number of independent measurements in order to estimate the bias and to validate the existing precision estimates of the MIPAS data. The estimated precision for MIPAS is 5 to 10% in the stratosphere, depending on altitude, latitude, and season. The independent instruments were: the Halogen Occultation Experiment (HALOE), the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Improved Limb Atmospheric Spectrometer-II (ILAS-II), the Polar Ozone and Aerosol Measurement (POAM III) instrument, the Middle Atmospheric Water Vapour Radiometer (MIAWARA), the Michelson Interferometer for Passive Atmospheric Sounding, balloon-borne version (MIPAS-B), the Airborne Microwave Stratospheric Observing System (AMSOS), the Fluorescent Stratospheric Hygrometer for Balloon (FLASH-B), the NOAA frostpoint hygrometer, and the Fast In Situ Hygrometer (FISH). For the in-situ measurements and the ground based, air- and balloon borne remote sensing instruments, the measurements are restricted to central and northern Europe. The comparisons to satellite-borne instruments are predominantly at mid- to high latitudes on both hemispheres. In the stratosphere there is no clear indication of a bias in MIPAS data, because the independent measurements in some cases are drier and in some cases are moister than the MIPAS measurements. Compared to the infrared measurements of MIPAS, measurements in the ultraviolet and visible have a tendency to be high, whereas microwave measurements have a tendency to be low. The results of χ2-based precision validation are somewhat controversial among the comparison estimates. However, for comparison instruments whose error budget also includes errors due to uncertainties in spectrally interfering species and where good coincidences were found, the χ2 values found are in the expected range or even below. This suggests that there is no evidence of systematically underestimated MIPAS random errors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

111 Domestic Shorthair cats with idiopathic hypertrophic cardiomyopathy were reviewed retrospectively. Two-dimensional echocardiography was used to classify cases in 6 established phenotypes. Hypertrophy was diffuse in 61 % of cats and involved major portions of the ventricular septum and the left ventricular free wall (phenotype D). In the remaining cats, distribution of hypertrophy was more segmental and was identified on the papillary muscles exclusively (phenotype A, 6 %), on the anterior and basal portion of the ventricular septum (phenotype B, 12 %), on the entire septum (phenotype C, 14 %), or on the left ventricular free wall (phenotype E, 7 %). Echocardiographic characteristics and clinical findings were determined for each phenotype to study the correlation between distribution of hypertrophy and clinical implications. 31 cats demonstrated systolic anterior motion of the mitral valve, 75 % of them belonged to phenotype C of hypertrophy. Left ventricular-outflow turbulences were identified more frequently with patterns of hypertrophy involving the ventricular septum (65.5 %), while prevalence of mitral regurgitation was higher when hypertrophy included the papillary muscles (phenotypes A and E, 85 % and 87 %, respectively). Left atrial dilatation occurred more frequently when hypertrophy was diffuse or confined to the left ventricular free wall (61 % of cats with phenotype D or E) rather than to the ventricular septum (31 % of cats with phenotype B or C).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiomyopathies are myocardial diseases that lead to cardiac dysfunction, heart failure, arrhythmia, and sudden death. In human medicine, cardiomyopathies frequently warrant heart transplantation in children and adults. Bovine dilated cardiomyopathy (BDCMP) is a heart muscle disorder that has been observed during the last 30 years in cattle of Holstein-Friesian origin. In Switzerland BDCMP affects Swiss Fleckvieh and Red Holstein breeds. BDCMP is characterized by a cardiac enlargement with ventricular remodeling and chamber dilatation. The common symptoms in affected animals are subacute subcutaneous edema, congestion of the jugular veins, and tachycardia with gallop rhythm. A cardiomegaly with dilatation and hypertrophy of all heart chambers, myocardial degeneration, and fibrosis are typical postmortem findings. It was shown that all BDCMP cases reported worldwide traced back to a red factor-carrying Holstein-Friesian bull, ABC Reflection Sovereign. An autosomal recessive mode of inheritance was proposed for BDCMP. Recently, the disease locus was mapped to a 6.7-Mb interval MSBDCMP06-BMS2785 on bovine Chr 18 (BTA18). In the present study the BDCMP locus was fine mapped by using a combined strategy of homozygosity mapping and association study. A BAC contig of 2.9 Mb encompassing the crucial interval was constructed to establish the correct marker order on BTA18. We show that the disease locus is located in a gene-rich interval of 1.0 Mb and is flanked by the microsatellite markers DIK3006 and MSBDCMP51.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS The aim of our study in patients with coronary artery disease (CAD) and present, or absent, myocardial ischaemia during coronary occlusion was to test whether (i) left ventricular (LV) filling pressure is influenced by the collateral circulation and, on the other hand, that (ii) its resistance to flow is directly associated with LV filling pressure. METHODS AND RESULTS In 50 patients with CAD, the following parameters were obtained before and during a 60 s balloon occlusion: LV, aortic (Pao) and coronary pressure (Poccl), flow velocity (Voccl), central venous pressure (CVP), and coronary flow velocity after coronary angioplasty (V(Ø-occl)). The following variables were determined and analysed at 10 s intervals during occlusion, and at 60 s of occlusion: LV end-diastolic pressure (LVEDP), velocity-derived (CFIv) and pressure-derived collateral flow index (CFIp), coronary collateral (Rcoll), and peripheral resistance index to flow (Rperiph). Patients with ECG signs of ischaemia during coronary occlusion (insufficient collaterals, n = 33) had higher values of LVEDP over the entire course of occlusion than those without ECG signs of ischaemia during occlusion (sufficient collaterals, n = 17). Despite no ischaemia in the latter, there was an increase in LVEDP from 20 to 60 s of occlusion. In patients with insufficient collaterals, CFIv decreased and CFIp increased during occlusion. Beyond an occlusive LVEDP > 27 mmHg, Rcoll and Rperiph increased as a function of LVEDP. CONCLUSION Recruitable collaterals are reciprocally tied to LV filling pressure during occlusion. If poorly developed, they affect it via myocardial ischaemia; if well grown, LV filling pressure still increases gradually during occlusion despite the absence of ischaemia indicating transmission of collateral perfusion pressure to the LV. With low, but not high, collateral flow, resistance to collateral as well as coronary peripheral flow is related to LV filling pressure in the high range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve. RESULTS 16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66). CONCLUSIONS Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dilatation of the ascending aorta is an important sequel in conotruncal anomalies, such as tetralogy of Fallot (TOF) or d-transposition of the great arteries (TGA). We measured dimensions and their progression at different levels of the ascending aorta in 80 patients. In TOF patients, mean z-score for aortic annulus was 1.65 (range -3.16-6.47), for sinus 1.93 (range -2.28-5.39), for st-junction 4.15 (range 0.0-8.18), and for ascending aorta 3.51 (range -1.23-6.36). Over time, annulus z-scores increased in the univariate analysis [0.07/year, 95 % confidence interval (CI) 0.01-0.14; p = 0.02], and this was unique to male patients (0.08/year, 95 % CI 0.00-0.15; p = 0.05). z-scores of the ascending aorta decreased (-0.1/year, 95 % CI -0.18 to -0.02; p = 0.02), and this was confined to patients without aortic regurgitation (AR; -0.09/year, 95 % CI -0.18 to -0.01; p = 0.04). In TGA, mean z-score for the aortic annulus was 2.13 (range -3.71-8.39), for sinus 1.77 (range -3.04-6.69), for st-junction 1.01 (range -5.44-6.71), and for ascending aorta 0.82 (range -4.91-6.46). In bivariate analysis, annulus z-scores decreased in females (-0.14/year, 95 % CI -0.25 to -0.03; p = 0.01) and in patients without AR (-0.07/year, 95 % CI -0.14-0.0; p = 0.03). z-scores of the ascending aorta increased significantly in males (0.08/year, 95 % CI 0.0 to 0.16; p = 0.05) and in patients with AR (0.12/year, 95 % CI 0.03-0.21; p = 0.01). In conclusion, TOF and TGA z-scores of the ascending aorta differ significantly from those of the normal population. Progression of z-scores over time is influenced by diagnosis, sex, and presence of AR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Up to one third of BKP treated cases shows no appreciable height restoration due to loss of both restored height and kyphotic realignment after balloon deflation. This shortcoming has called for an improved method that maintains the height and realignment reached by the fully inflated balloon until stabilization of the vertebral body by PMMA-based cementation. Restoration of the physiological vertebral body height for pain relief and for preventing further fractures of adjacent and distant vertebral bodies must be the main aim for such a method. A new vertebral body stenting system (VBS) stabilizes the vertebral body after balloon deflation until cementation. The radiographic and safety results of the first 100 cases where VBS was applied are presented. METHODS During the planning phase of an ongoing international multicenter RCT, radiographic, procedural and followup details were retrospectively transcribed from charts and xrays for developing and testing the case report forms. Radiographs were centrally assessed at the institution of the first/senior author. RESULTS 100 patients (62 with osteoporosis) with a total of 103 fractured vertebral bodies were treated with the VBS system. 49 were females with a mean age of 73.2 years; males were 66.7 years old. The mean preoperative anterior-middle-posterior heights were 20.3-17.6-28.0 mm, respectively. The mean local kyphotic angle was 13.1[degree sign]. The mean preoperative Beck Index (anterior edge height/posterior edge height) was 0.73, the mean alternative Beck Index (middle height/posterior edge height) was 0.63. The mean postoperative heights were restored to 24.5-24.6-30.4 mm, respectively. The mean local kyphotic angle was reduced to 8.9[degree sign]. The mean postoperative Beck Index was 0.81, the mean alternative one was 0.82. The overall extrusion rate was 29.1%, the symptomatic one was 1%. In the osteoporosis subgroup there were 23.8% extrusions. Within the three months followup interval there were 9% of adjacent and 4% of remote new fractures, all in the osteoporotic group. CONCLUSIONS VBS showed its strengths especially in realignment of crush and biconcave fractures. Given that fracture mobility is present, the realignment potential is sound and increases with the severity of preoperative vertebral body deformation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Acute exposure to high altitude stimulates free radical formation in lowlanders, yet whether this persists during chronic exposure in healthy, well-adapted and maladapted highlanders suffering from chronic mountain sickness (CMS) remains to be established. METHODS Oxidative-nitrosative stress (as determined by the presence of the biomarkers ascorbate radical [A •- ], via electron paramagnetic resonance spectroscopy, and nitrite [NO 2 2 ], via ozone-based chemiluminescence) was assessed in venous blood of 25 male highlanders in Bolivia living at 3,600 m with CMS (n 5 13, CMS 1 ) and without CMS (n 5 12, CMS 2 ). Twelve age- and activity-matched, healthy, male lowlanders were examined at sea level and during acute hypoxia. We also measured fl ow-mediated dilatation (FMD), arterial stiffness defined by augmentation index normalized for a heart rate of 75 beats/min (AIx-75), and carotid intima-media thickness (IMT). RESULTS Compared with normoxic lowlanders, oxidative-nitrosative stress was moderately increased in the CMS 2 group ( P , .05), as indicated by elevated A •- (3,191 457 arbitrary units [AU] vs 2,640 445 AU) and lower NO 2 2 (206 55 nM vs 420 128 nM), whereas vascular function remained preserved. This was comparable to that observed during acute hypoxia in lowlanders in whom vascular dysfunction is typically observed. In contrast, this response was markedly exaggerated in CMS 1 group (A •- , 3,765 429 AU; NO 2 2 , 148 50 nM) compared with both the CMS 2 group and lowlanders ( P , .05). This was associated with systemic vascular dysfunction as indicated by lower ( P , .05 vs CMS 2 ) FMD (4.2% 0.7% vs 7.6% 1.7%) and increased AIx-75 (23% 8% vs 12% 7%) and carotid IMT (714 127 m M vs 588 94 m M). CONCLUSIONS Healthy highlanders display a moderate, sustained elevation in oxidative-nitrosative stress that, unlike the equivalent increase evoked by acute hypoxia in healthy lowlanders, failed to affect vascular function. Its more marked elevation in patients with CMS may contribute to systemic vascular dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To expand the limited information on the prognostic impact of quantitatively obtained collateral function in patients with coronary artery disease (CAD) and to estimate causality of such a relation. DESIGN Prospective cohort study with long-term observation of clinical outcome. SETTING University Hospital. PATIENTS One thousand one hundred and eighty-one patients with chronic stable CAD undergoing 1771 quantitative, coronary pressure-derived collateral flow index measurements, as obtained during a 1-min coronary balloon occlusion (CFI is the ratio between mean distal coronary occlusive pressure and mean aortic pressure both subtracted by central venous pressure). Subgroup of 152 patients included in randomised trials on the longitudinal effect of different arteriogenic protocols on CFI. INTERVENTIONS Collection of long-term follow-up information on clinical outcome. MAIN OUTCOME MEASURES All-cause mortality and major adverse cardiac events. RESULTS Cumulative 15-year survival rate was 48% in patients with CFI<0.25 and 65% in the group with CFI≥0.25 (p=0.0057). Cumulative 10-year survival rate was 75% in patients without arteriogenic therapy and 88% (p=0.0482) in the group with arteriogenic therapy and showing a significant increase in CFI at follow-up. By proportional hazard analysis, the following variables predicted increased all-cause mortality: age, low CFI, left ventricular end-diastolic pressure and number of vessels with CAD. CONCLUSIONS A well-functioning coronary collateral circulation independently predicts lowered mortality in patients with chronic CAD. This relation appears to be causal, because augmented collateral function by arteriogenic therapy is associated with prolonged survival.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The use of ultrathin Doppler angioplasty guidewires has made it possible to measure collateral flow quantitatively. Pharmacologic interventions have been shown to influence collateral flow and, thus, to affect myocardial ischaemia. METHODS Twenty-five patients with coronary artery disease undergoing PTCA were included in the present analysis. Coronary flow velocities were measured in the ipsilateral (n = 25) and contralateral (n = 6; two Doppler wires) vessels during PTCA with and without i.v. adenosine (140 microg/kg.min) before and 3 min after 5 mg metoprolol i.v., respectively. The ipsilateral Doppler wire was positioned distal to the stenosis, whereas the distal end of the contralateral wire was in an angiographically normal vessel. The flow signals of the ipsilateral wire were used to calculate the collateral flow index (CFI). CFI was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS Heart rate and mean aortic pressure decreased slightly (ns) after i.v. metoprolol. The collateral flow index was 0.25+/-0.12 (one fourth of the resting coronary flow) during the first PTCA and 0.27+/-0.14 (ns versus first PTCA) during the second PTCA, but decreased with metoprolol to 0.16+/-0.08 (p<0.0001 vs. baseline) during the third PTCA. CONCLUSIONS Coronary collateral flow increased slightly but not significantly during maximal vasodilatation with adenosine but decreased in 23 of 25 patients after i.v. metoprolol. Thus, there is a reduction in coronary collateral flow with metoprolol, probably due to an increase in coronary collateral resistance or a reduction in oxygen demand.