192 resultados para Venous Thrombosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. METHODS: We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. RESULTS: Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. CONCLUSIONS: Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent thrombosis (ST) after percutaneous coronary intervention has been the focus of intense interest because of its attendant morbidity and mortality. There is controversy about several facets of the problem. These include the frequency of ST with drug-eluting stents (DES) versus bare-metal stents (BMS), the timing of the event, clinical consequences, risk factors, adjunctive therapy, and new preventive approaches. Information has accrued rapidly from several sources, including randomized controlled clinical trials of DES versus BMS in carefully selected subsets of patients and registry experiences in larger patient groups, which provide a more universal real-world picture. The results from these different data sets are not completely concordant. However, several general conclusions can be made: 1) ST is an infrequent but very severe complication of both BMS and DES; 2) at the present time, during 4 years of follow-up from randomized controlled trials that compared DES and BMS, there is no apparent difference in overall ST frequency, although the time course for occurrence appears to differ, with a relative numeric excess of ST late after DES implant; 3) despite this relative imbalance, no differences in the end points of death or death and infarction between DES and BMS are observed; 4) longer-term follow-up of these patients as well as larger angiographic and clinical subsets of patients who receive this technology outside of randomized trials are required to fully study this issue; and 5) advances in stent platforms for drug elution as well as adjunctive pharmacologic therapy are being evaluated to enhance long-term safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 52-year-old female patient with known cerebral cavernomas and acute headache. A cranial CT scan excluded an intracranial bleeding. Cavernomas are rare vascular malformations of the venous blood system (synon. cavernous angiomas) with a slow blood flow. Clinical manifestation is presented between an age of 30-50 years with mostly unspecific neurological symptoms like headache, nausea, vomiting and dizziness, but also epileptic seizures and bleedings may occur. In general, therapy is symptomatic. In cases of seizures, however, anticonvulsive treatment is indicated. Operation can be discussed for peripheral localized cavernomas with bleeding or for refractory seizures. If antiplatelet or anticoagulation therapy is necessary due to other diseases (coronary heart disease, atrial fibrillation, thrombosis, pulmonary embolism), cerebral cavernomas are not considered as an absolute contraindication. The risk for an ischemic stroke under atrial fibrillation (5-20%), for example, is higher than the risk for bleeding of a cerebral cavernoma under anticoagulation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the case of a 46-year-old man who underwent elective percutaneous coronary intervention and stenting of the left anterior descending artery and right coronary artery with two sirolimus- and paclitaxel-eluting stents. Four days after angioplasty, he was readmitted with cardiogenic shock due to acute anterior and inferior myocardial infarction. Coronary angiography revealed subacute thrombosis of both stents, and balloon dilation was performed successfully thereafter. The follow-up investigations revealed that the patient was a carrier of factor V Leiden. We hereby discuss the importance of factor V Leiden as the most common cause of hypercoagulable state and its probable role in acute and subacute coronary stent thrombosis in drug-eluting stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine the risk of late stent thrombosis (ST) during long-term follow-up beyond 3 years, searched for predictors, and assessed the impact of ST on overall mortality. BACKGROUND: Late ST was reported to occur at an annual rate of 0.6% up to 3 years after drug-eluting stent (DES) implantation. METHODS: A total of 8,146 patients underwent percutaneous coronary intervention with a sirolimus-eluting stent (SES) (n=3,823) or paclitaxel-eluting stent (PES) (n=4,323) and were followed up to 4 years after stent implantation. Dual antiplatelet treatment was prescribed for 6 to 12 months. RESULTS: Definite ST occurred in 192 of 8,146 patients with an incidence density of 1.0/100 patient-years and a cumulative incidence of 3.3% at 4 years. The hazard of ST continued at a steady rate of 0.53% (95% confidence interval [CI]: 0.44 to 0.64) between 30 days and 4 years. Diabetes was an independent predictor of early ST (hazard ratio [HR]: 1.96; 95% CI: 1.18 to 3.28), and acute coronary syndrome (HR: 2.21; 95% CI: 1.39 to 3.51), younger age (HR: 0.97; 95% CI: 0.95 to 0.99), and use of PES (HR: 1.67; 95% CI: 1.08 to 2.56) were independent predictors of late ST. Rates of death and myocardial infarction at 4 years were 10.6% and 4.6%, respectively. CONCLUSIONS: Late ST occurs steadily at an annual rate of 0.4% to 0.6% for up to 4 years. Diabetes is an independent predictor of early ST, whereas acute coronary syndrome, younger age, and PES implantation are associated with late ST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Umbilical venous catheters allow rapid central access in neonates, but may be associated with various complications. We present a case of a newborn with pericardial effusion following umbilical venous catheterization. An extremely low birth weight infant was intubated for respiratory distress syndrome and had umbilical venous and arterial lines in place. Massive cardiomegaly was noted on the subsequent chest X-ray. Echocardiography revealed a large pericardial effusion without signs of tamponade. After removing the catheter, the effusion gradually resolved. While pericardial effusion is a well-known complication of percutaneous long central lines, only a few case reports have documented sudden cardiovascular compromise associated with umbilical venous catheters. Pericardial effusion may be asymptomatic and should be suspected in infants with central catheters and progressive cardiomegaly. The prompt removal of catheters and, if signs of cardiac tamponade are present, emergency pericardiocentesis may prove to be life-saving.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug-eluting stents (DES) have reduced the risk of repeat revascularization procedures by 50-70% compared with bare metal stents across a wide range of lesion and patients subsets. Stent thrombosis is a rare but devastating adverse event, which results in abrupt closure of the treated artery with the incumbent risk of sudden death or myocardial infarction. Although stent thrombosis has been recognized as a shortcoming of coronary artery stents since there inception, very late stent thrombosis occurring more than one year after stent implantation emerged as a new entity complicating the use of DES. The mechanisms leading to very late ST are complex and only incompletely understood. Delayed healing and incomplete re-endothelialization emerged as prevailing mechanism of thrombosis in autopsy studies. Various components of DES may give rise to very late stent thrombosis, notably the polymers used for controlled drug-release. Newer generation DES attempt to address these concerns by aiming at improved vascular healing while maintaining potent neointimal suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elevated platelet count might reflect increased inflammation as an etiological factor for venous thromboembolism (VTE). Poor sleep, fatigue, and exhaustion are all associated with inflammation and are also common sequelae of chronic psychological stress that previously predicted increased risk of VTE. We hypothesized that platelet count would be high in patients with VTE who sleep poorly and who are fatigued and exhausted. We investigated 205 patients scheduled for thrombophilia work-up > or =3 months after an objectively diagnosed venous thromboembolic event. They completed the Jenkins Sleep Questionnaire to rate subjective sleep quality and the short forms of the Multidimensional Fatigue Symptom Inventory and Maastricht Vital Exhaustion Questionnaire. Platelet count was determined by a mechanical Coulter counter. Analyses controlled for age, sex, body mass index, time since the index event, and medication. After taking into account these covariates, poorer sleep quality (p = 0.001; DeltaR(2)= 0.046), high fatigue (p = 0.008; DeltaR(2)= 0.032), and vital exhaustion (p = 0.050; DeltaR(2)= 0.017) were all associated with elevated platelet count. In addition, high level of fatigue mediated the relationship between poor sleep quality and elevated platelet count (p = 0.046). Poor sleep quality, high levels of fatigue, and vital exhaustion were identified as correlates of an elevated platelet count in patients with a previous episode of VTE. Given the emerging role of inflammatory processes in VTE, the findings suggest a mechanism through which behavioral and chronic psychological stressors might contribute to incident and recurrent venous thrombotic events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.