256 resultados para Stent-graft


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To compare the long-term relative efficacy and safety of SES and PES in patients undergoing percutaneous coronary intervention (PCI) for unprotected left main coronary artery (ULMCA) disease and to evaluate the role of lesion location and stenting technique in determining outcomes. METHODS AND RESULTS: From April 2002 to April 2004, 288 consecutive patients who underwent elective PCI with DES implantation for de novo lesions on ULMCA have been retrospectively selected and analyzed in seven European and US tertiary care centers. All patients had a minimum follow-up of 3 years. SES was used in 152 patients while 136 received PES. Isolated ostial-shaft disease was present in 27% of patients. Distal LM disease (73%) was treated with single and double stent approach in 29.5% and 43.4% of patients respectively. After 3 years, rates of survival free from any of the events investigated, were independent from lesion location and stenting approach and did not differ significantly between SES and PES groups. Freedom from MACE (SES vs. PES) was 76.3% vs. 83.1% in the ostial/shaft group, 80.3% vs. 72.8% in the distal-single stent group and 67.1% vs. 66.2% in the distal-double stent group. Definite stent thrombosis occurred only in 1(0.3%) patient at 439 days. CONCLUSIONS: In elective patients who underwent PCI for de novo lesions in the ostium, shaft or distal ULMCA, long-term clinical outcomes with SES and PES use were similar independently of lesion location and stenting technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to investigate the long-term safety and efficacy of percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation for unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Long-term clinical outcomes after DES implantation for ULMCA disease have not yet been ascertained. METHODS: From April 2002 to April 2004, 358 consecutive patients who underwent PCI with DES implantation for de novo lesions on ULMCA were retrospectively selected and analyzed in 7 European and U.S. tertiary care centers. No patients were excluded from the analysis, and all patients had a minimum follow-up of 3 years. RESULTS: Technical success rate was 100%. Procedural success rate was 89.6%. After 3 years, major adverse cardiovascular events (MACE)-free survival in the whole population was 73.5%. According to the Academic Research Consortium definitions, cardiac death occurred in 9.2% of patients, and reinfarction, target lesion revascularization (TLR), and target vessel revascularization (TVR) occurred in 8.6%, 5.8%, and 14.2% of patients, respectively. Definite stent thrombosis occurred in 2 patients (specifically at 0 and 439 days). In elective patients, the 3-year MACE-free survival was 74.2%, with mortality, reinfarction, TLR, and TVR rates of 6.2%, 8.3%, 6.6%, and 16%, respectively. In the emergent group the 3-year MACE-free survival was 68.2%, with mortality, reinfarction, TLR, and TVR rates of 21.4%, 10%, 2.8%, and 7.1%, respectively. CONCLUSIONS: Routine DES implantation in ULMCA disease seems encouraging, with favorable long-term clinical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the case of a 46-year-old man who underwent elective percutaneous coronary intervention and stenting of the left anterior descending artery and right coronary artery with two sirolimus- and paclitaxel-eluting stents. Four days after angioplasty, he was readmitted with cardiogenic shock due to acute anterior and inferior myocardial infarction. Coronary angiography revealed subacute thrombosis of both stents, and balloon dilation was performed successfully thereafter. The follow-up investigations revealed that the patient was a carrier of factor V Leiden. We hereby discuss the importance of factor V Leiden as the most common cause of hypercoagulable state and its probable role in acute and subacute coronary stent thrombosis in drug-eluting stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical value of early exercise stress testing (EST) after coronary stenting to predict long-term clinical outcomes is unknown. Of 1,000 unselected patients who underwent coronary stenting, 446 random patients underwent early EST the day after intervention. Clinical long-term outcomes (41 +/- 20 months) were correlated with normal (n = 314 [70%]) or positive (n = 102 [23%]) EST results. Patients with inconclusive test results (n = 30 [7%]) were excluded from the analysis. Overall mortality was significantly higher in patients with positive EST results (9.3% vs 3.9%, p = 0.04). Major adverse cardiac events and cardiac mortality also tended to be higher in patients with positive stress test results (45.4% vs 35.4%, p = 0.08, and 4.1% vs 1.1%, p = 0.05, respectively). Patients with the combination of positive stress test results and incomplete revascularization appeared to be the group at highest risk for major adverse cardiac events (47.1% vs 33.3% for patients with normal stress test results and complete revascularization, p = NS). Negative stress test results reduced (odds ratio 0.329, 95% confidence interval 0.120 to 0.905, p = 0.031) and a lower ejection fraction increased (odds ratio 0.942, 95% confidence interval 0.897 to 0.989, p = 0.017) the risk for death. In conclusion, an early stress test after coronary stenting provides important prognostic information. Positive stress test results, especially in combination with incomplete revascularization, are associated with higher mortality, a trend toward more repeat revascularization procedures, and higher risk for major adverse cardiac events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Flow mismatch between the supplying artery and the myocardial perfusion region has been observed in patients with internal thoracic artery grafts. Thus coronary flow changes of arterial (internal thoracic artery grafts) and saphenous (saphenous vein grafts) bypass grafts were studied early and late after coronary artery bypass grafting. METHODS: Thirty patients undergoing elective bypass surgery (internal thoracic artery and saphenous vein grafts) were studied intraoperatively and (17 patients) 3 to 10 months postoperatively. Coronary flow was measured intraoperatively with the transit-time Doppler scanning technique. Postoperatively, flow velocity and coronary flow reserve were determined with the Doppler flow wire technique. Quantitative angiographic analysis was used to determine vessel size for calculation of absolute flow. RESULTS: Intraoperatively, internal thoracic artery graft flow was significantly lower than saphenous vein graft flow (31 +/- 8 vs 58 +/- 29 mL/min, P < .01). Postoperatively, internal thoracic artery graft flow increased significantly to 42 +/- 24 mL/min at 3 months and to 56 +/- 30 mL/min (P < .02 vs intraoperative value) at 10 months, respectively. However, saphenous vein graft flow remained unchanged over time (58 +/- 29 to 50 +/- 27 mL/min at 3 months and 46 +/- 27 mL/min at 10 months). Coronary flow reserve was abnormally low intraoperatively in the internal thoracic artery (1.3 +/- 0.3) and saphenous vein (1.6 +/- 0.5) grafts but increased significantly to normal values in both types of graft at follow-up. CONCLUSIONS: Bypass flow of the internal thoracic artery graft is significantly reduced intraoperatively when compared with that of the saphenous vein graft. However, 3 and 10 months after the operation, flow of the internal thoracic artery graft increases significantly and is similar to saphenous vein graft flow. This finding can be explained by an early flow mismatch of the native internal thoracic artery in the presence of a large perfusion territory. During follow-up, there is vascular remodeling of the internal thoracic artery, probably because of endothelium-mediated mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was performed to evaluate feasibility, efficacy, and safety of intracranial artery recanalization for acute ischemic stroke using a self-expandable stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotational atherectomy has been regaining interest over the last couple of years after it almost has disappeared from most interventional catheterization laboratories for several years due to failure to prove its original concept of improving long term results of percutaneous coronary interventions (PCI) as was repeatedly shown in studies in the 1990s. Its revival coupled the introduction of drug-eluting stents (DES); these devices have led to treating much more complex lesions and high-risk patients by PCI. However, real-world experience suggested that off-label use of DES is associated with a higher rate of early and late stent thrombosis. Therefore, more attention is now being paid to the initial implantation technique of DES including aggressive lesion preparation to facilitate stent delivery and expansion. The limited studies with rot-ablation and DES showed promising results with no long term safety concerns. In these studies, a subtle observation was made suggesting that rot-ablation prior to DES implantation in such lesions may have an add-on effect on long term outcome compared to DES alone. An ongoing multicenter study is investigating such effect among complex calcified coronary lesions. Even if this additive benefit does not prove true, rot-ablation remains an efficient tool for preparing certain lesions to facilitate effective and safe DES implantation. Therefore, interventional training programs should focus on this difficult technique to bridge the gap of experience which resulted from neglecting it for several years. In this regard, dedicated courses at experienced sites as well as medical simulation may be appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modified American College of Cardiology/American Heart Association (ACC/AHA) lesion morphology classification scheme has prognostic impact for early and late outcomes when bare-metal stents are used. Its value after drug-eluting stent placement is unknown. The predictive value of this lesion morphology classification system in patients treated using sirolimus-eluting stents included in the German Cypher Registry was prospectively examined. The study population included 6,755 patients treated for 7,960 lesions using sirolimus-eluting stents. Lesions were classified as type A, B1, B2, or C. Lesion type A or B1 was considered simple (35.1%), and type B2 or C, complex (64.9%). The combined end point of all deaths, myocardial infarction, or target vessel revascularization was seen in 2.6% versus 2.4% in the complex and simple groups, respectively (p = 0.62) at initial hospital discharge, with a trend for higher rates of myocardial infarction in the complex group. At the 6-month clinical follow-up and after adjusting for other independent factors, the composite of cumulative death, myocardial infarction, and target vessel revascularization was nonsignificantly different between groups (11.4% vs 11.2% in the complex and simple groups, respectively; odds ratio 1.08, 95% confidence interval 0.8 to 1.46). This was also true for target vessel revascularization alone (8.3% of the complex group, 9.0% of the simple group; odds ratio 0.87, 95% confidence interval 0.72 to 1.05). In conclusion, the modified ACC/AHA lesion morphology classification system has some value in determining early complications after sirolimus-eluting stent implantation. Clinical follow-up results at 6 months were generally favorable and cannot be adequately differentiated on the basis of this lesion morphology classification scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine the risk of late stent thrombosis (ST) during long-term follow-up beyond 3 years, searched for predictors, and assessed the impact of ST on overall mortality. BACKGROUND: Late ST was reported to occur at an annual rate of 0.6% up to 3 years after drug-eluting stent (DES) implantation. METHODS: A total of 8,146 patients underwent percutaneous coronary intervention with a sirolimus-eluting stent (SES) (n=3,823) or paclitaxel-eluting stent (PES) (n=4,323) and were followed up to 4 years after stent implantation. Dual antiplatelet treatment was prescribed for 6 to 12 months. RESULTS: Definite ST occurred in 192 of 8,146 patients with an incidence density of 1.0/100 patient-years and a cumulative incidence of 3.3% at 4 years. The hazard of ST continued at a steady rate of 0.53% (95% confidence interval [CI]: 0.44 to 0.64) between 30 days and 4 years. Diabetes was an independent predictor of early ST (hazard ratio [HR]: 1.96; 95% CI: 1.18 to 3.28), and acute coronary syndrome (HR: 2.21; 95% CI: 1.39 to 3.51), younger age (HR: 0.97; 95% CI: 0.95 to 0.99), and use of PES (HR: 1.67; 95% CI: 1.08 to 2.56) were independent predictors of late ST. Rates of death and myocardial infarction at 4 years were 10.6% and 4.6%, respectively. CONCLUSIONS: Late ST occurs steadily at an annual rate of 0.4% to 0.6% for up to 4 years. Diabetes is an independent predictor of early ST, whereas acute coronary syndrome, younger age, and PES implantation are associated with late ST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Diabetes mellitus (DM) plays an important role in the development of coronary artery disease. Although previous studies have associated drug-eluting stent (DES) implantation in diabetic patients with favourable clinical and angiographic outcomes, the very long-term efficacy of these devices in diabetic patients undergoing PCI for significant unprotected left main coronary artery (ULMCA) disease has not been established yet. METHODS AND RESULTS: Consecutive diabetic patients (n=100), who underwent elective PCI with DES for de novo lesions in an ULMCA between April 2002 and April 2004 in seven tertiary health care centres, were identified retrospectively and analysed. Consecutive non-diabetic patients (n=193), who underwent elective DES implantation for unprotected ULMCA disease, were selected as a control group. All patients were followed for at least 36 months. At 3-years follow-up, freedom from cardiac death ; myocardial infarction (CDMI), target lesion revascularisation (TLR) and target vessel revascularisation (TVR) did not differ significantly between groups. The adjusted freedom from major adverse cardiac events (MACE, defined as the occurrence of CD, MI or TVR) was 63.4% in the DM group and 77.6% in the controls (p<0.001). When divided into IDDM and NIDDM sub-groups, insulin-dependent DM (IDDM) but not non IDDM (NIDDM) patients had significantly lower freedom from CDMI, TLR, TVR and MACE compared to controls. CONCLUSIONS: These results suggest that major improvements in DES technology and pharmacotherapy are still required to improve clinical outcome and that the decision to perform percutaneous revascularisation in this subset of patients should be taken cautiously and on a case by case basis.