155 resultados para Sigmund, Archduke of Austria, 1427-1496.
Resumo:
OBJECTIVES The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Inc., Santa Rosa, California) in patients with coronary artery disease and diabetes. BACKGROUND The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. METHODS We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. RESULTS The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p < 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with noninsulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). CONCLUSIONS The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with noninsulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Medtronic RESOLUTE Clinical Trial; NCT00248079; Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; The Medtronic RESOLUTE US Clinical Trial (R-US); NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [R-Int]; NCT00752128; RESOLUTE Japan-The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent [RJ]; NCT00927940).
Resumo:
BACKGROUND Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes--including death and myocardial infarction (MI)--in clinical studies. OBJECTIVES To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). DESIGN Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. SETTING Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrollment criteria were generally unrestrictive. PATIENTS 5130 patients. MAIN OUTCOME MEASURES 2-year clinical outcomes and 13-month angiographic outcomes. RESULTS 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES. CONCLUSIONS Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes--including repeat revascularisation--to non-overlapping DES.
Resumo:
In this article, we analyze political parties' campaign communication during the 2009 European Parliamentary election in 11 countries (Austria, Bulgaria, Czech Republic, Germany, Hungary, The Netherlands, Poland, Portugal, Spain, Sweden, and the UK). We study which types of issues Euroskeptic fringe and Euroskeptic mainstream parties put on their campaign agendas and the kind and extent of EU opposition they voice. Further, we seek to understand whether Euroskeptic and non-Euroskeptic parties co-orient themselves toward each other within their national party systems with regard to their campaigns. To understand the role of Euroskeptic parties in the 2009 European Parliamentary elections, we draw on a systematic content analysis of parties' posters and televised campaign spots. Our results show that it is Euroskeptic parties at the edges of the political spectrum who discuss polity questions of EU integration and who most openly criticize the union. Principled opposition against the project of EU integration, however, can only be observed in the UK. Finally, we find indicators for co-orientation effects regarding the tone of EU mobilization: In national political environments where Euroskeptic parties strongly criticize the EU, pro-European parties at the same time publicly advance pro-EU positions.
Resumo:
Over the past several years the topics of energy consumption and energy harvesting have gained significant importance as a means for improved operation of wireless sensor and mesh networks. Energy-awareness of operation is especially relevant for application scenarios from the domain of environmental monitoring in hard to access areas. In this work we reflect upon our experiences with a real-world deployment of a wireless mesh network. In particular, a comprehensive study on energy measurements collected over several weeks during the summer and the winter period in a network deployment in the Swiss Alps is presented. Energy performance is monitored and analysed for three system components, namely, mesh node, battery and solar panel module. Our findings cover a number of aspects of energy consumption, including the amount of load consumed by a mesh node, the amount of load harvested by a solar panel module, and the dependencies between these two. With our work we aim to shed some light on energy-aware network operation and to help both users and developers in the planning and deployment of a new wireless (mesh) network for environmental research.
Resumo:
OBJECTIVE Measuring children's health-related quality of life (HRQOL) is of growing importance given increasing chronic diseases. By integrating HRQOL questions into the European GABRIEL study, we assessed differences in HRQOL between rural farm and non-farm children from Germany, Austria, Switzerland and Poland to relate it to common childhood health problems and to compare it to a representative, mostly urban German population sample (KIGGS). METHODS The parents of 10,400 school-aged children answered comprehensive questionnaires including health-related questions and the KINDL-R questions assessing HRQOL. RESULTS Austrian children reported highest KINDL-R scores (mean: 80.9; 95 % CI [80.4, 81.4]) and Polish children the lowest (74.5; [73.9, 75.0]). Farm children reported higher KINDL-R scores than non-farm children (p = 0.002). Significantly lower scores were observed in children with allergic diseases (p < 0.001), with sleeping difficulties (p < 0.001) and in overweight children (p = 0.04). The German GABRIEL sample reported higher mean scores (age 7-10 years: 80.1, [79.9, 80.4]; age 11-13 years: 77.1, [74.9, 79.2]) compared to the urban KIGGS study (age 7-10 years: 79.0, [78.7-79.3]; age 11-13 years: 75.1 [74.6-75.6]). Socio-demographic or health-related factors could not explain differences in HRQOL between countries. CONCLUSIONS Future increases in chronic diseases may negatively impact children's HRQOL.
Resumo:
A microbiopsy system for fast excision and transfer of biological specimens from donor to high-pressure freezer was developed. With a modified, commercially available, Promag 1.2 biopsy gun, tissue samples can be excised with a size small enough (0.6 mm x 1.2 mm x 0.3 mm) to be easily transferred into a newly designed specimen platelet. A self-made transfer unit allows fast transfer of the specimen from the needle into the specimen platelet. The platelet is then fixed in a commercially available specimen holder of a high-pressure freezing machine (EM PACT, Leica Microsystems, Vienna, Austria) and frozen therein. The time required by a well-instructed (but not experienced) person to execute all steps is in the range of half a minute. This period is considered short enough to maintain the excised tissue pieces close to their native state. We show that a range of animal tissues (liver, brain, kidney and muscle) are well preserved. To prove the quality of freezing achieved with the system, we show vitrified ivy leaves high-pressure frozen in the new specimen platelet.
Resumo:
Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79 as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.
Resumo:
Aims: To compare clinical outcomes after percutaneous coronary intervention (PCI) between patients with acute coronary syndromes (ACS) and those with stable ischaemic heart disease (SIHD) stratified by anatomic disease complexity (SYNTAX score). Methods and results: Patient-level data from three all-comers PCI trials were pooled. Patients (n=4,204) were stratified by clinical presentation (i.e., ACS or SIHD) and by SYNTAX score (i.e., lowest vs. two highest tertiles). The major adverse cardiac event (MACE) rates of patients with low-risk SIHD (n=531) and high-risk SIHD (n=1,066) were compared with ACS patients (n=2,607), respectively. At two years, the risk of MACE was higher for high-risk SIHD patients (OR 1.34, 95% CI: 1.08-1.66) and lower for low-risk SIHD patients (OR 0.61, 95% CI: 0.43-0.87) compared with ACS patients, respectively. This difference between high-risk SIHD patients and ACS patients was primarily driven by a higher risk of myocardial infarction (OR 1.64, 95% CI: 1.21-2.21), while there was no difference for cardiac death (OR 0.77, 95% CI: 0.49-1.21) or target lesion revascularisation (OR 1.21, 95% CI: 0.91-1.62). Conclusions: In this pooled analysis, the majority of patients undergoing PCI for SIHD (i.e., with SYNTAX score >8) had a higher risk of MACE than patients with ACS. Trial registration: URL: http://www.ClinicalTrials.gov; unique identifier: NCT00297661 (Sirtax), NCT00389220 (Leaders), NCT00114972 (Resolute-AC).
Resumo:
Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H --> gamma-gamma, H --> ZZ* --> 4 leptons and H --> WW --> 2 leptons + 2 neutrinos. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of 7 TeV and 8 TeV, corresponding to an integrated luminosity of about 25/fb. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined fits probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson.
Resumo:
AIM To compare treatment strategies for respiratory failure in extremely low birth weight (ELBW) infants in Germany in 1997 to Germany, Austria and Switzerland in 2011. METHODS A detailed questionnaire about treatment strategies for ELBW infants was sent to all German centres treating ELBW infants in 1997. A follow-up survey was conducted in 2011 in Germany, Austria and Switzerland. RESULTS In 1997 and 2011, 63.6% and 66.2% of the hospitals responded. In 2011 the response rate was higher in Switzerland than in Germany, and in university hospitals versus non-university hospitals. Treatment strategies did not differ between university and non-university hospitals as well as NICUs of different sizes in 2011. Differences between Germany, Austria and Switzerland were minimal. Administration of caffeine increased significantly, whereas theophylline and doxapram declined (all p<0.001). While the use of dexamethasone decreased and the use of hydrocortisone increased, the overall use of corticosteroids declined (all p<0.001). Between 1997 and 2011 therapy with inhalations and mucolytics decreased (both p<0.001) whereas the use application of diuretics did not change significantly. In mechanically ventilated infants the application of muscle relaxants and sedation declined significantly (p=0.009 and p<0.001), whereas analgesia use did not change. CONCLUSION Treatment strategies for respiratory failure in ELBW infants have changed significantly between 1997 and 2011. This article is protected by copyright. All rights reserved.