171 resultados para Plaque vulnérable


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The objective of this trial was to compare the survival rates of mandibular lingual retainers bonded with either chemically cured or light-cured adhesive after orthodontic treatment. METHODS Patients having undergone orthodontic treatment at a private orthodontic office were randomly allocated to fixed retainers placed with chemically cured composite or light-cured composite. Eligibility criteria included no active caries, restorations, or fractures on the mandibular anterior teeth, and adequate oral hygiene. The main outcome was any type of first-time lingual retainer breakage; pattern of failure (adapted adhesive remnant index scores) was a secondary outcome. Randomization was accomplished with random permuted blocks of 20 patients with allocation concealed in sequentially numbered, opaque, sealed envelopes. Blinding was applicable for outcome assessment only. Patients were reviewed at 1, 3, and 6 months and then every 6 months after placement of the retainer until completion of the study. Data were analyzed using survival analysis including Cox regression; sensitivity analysis was carried out after data imputation for subjects lost to follow-up. RESULTS Two hundred twenty patients (median age, 16 years; interquartile range, 2; range, 12-47 years) were randomized in a 1:1 ratio to either chemical or light curing. Baseline characteristics were similar between groups, the median follow-up period was 2.19 years (range, 0.003-3.64 years), and 16 patients were lost to follow-up. At a minimum follow-up of 2 years, 47 of 110 (42.7%) and 55 of 110 (50.0%) retainers had some type of failure with chemically cured and light-cured adhesive, respectively (log-rank test, P = 0.35). Data were analyzed on an intention-to-treat basis, and the hazard ratio (HR) was 1.15 (95% confidence interval [CI], 0.88-1.70; P = 0.47). There was weak evidence that age is a significant predictor for lingual retainer failures (HR, 0.96; 95% CI, 0.93-1.00; P = 0.08). Adhesive remnant index scoring was possible for only 66 of the 102 (64.7%) failures and did not differ between composites (Fisher exact test, P = 0.16). No serious harm was observed other than gingivitis associated with plaque accumulation. CONCLUSIONS The results of this study indicated no evidence that survival of mandibular lingual retainers differs between chemically and light-cured adhesives. The overall failure rate was 46.4%; however, this included any type of failure, which may have exaggerated the overall failure rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of this prospective, randomized, controlled clinical study was to compare the clinical outcomes of the subgingival treatment with erythritol powder by means of an air-polishing (EPAP) device and of scaling and root planing (SRP) during supportive periodontal therapy (SPT). METHOD AND MATERIALS 40 patients enrolled in SPT were randomly assigned to two groups of equal size. Sites had to show signs of inflammation (bleeding on probing [BOP]-positive) and a probing pocket depth (PPD) of ≥ 4 mm, however, without presence of detectable subgingival calculus. During SPT, these sites were treated with EPAP or SRP, respectively. Full mouth and site-specific plaque indices, BOP, PPD, and clinical attachment level (CAL) were recorded at baseline (BL) and at 3 months, whereas the percentage of study sites positive for BOP (BOP+) was considered as primary outcome variable. Additionally, patient comfort using a visual analog scale (VAS) and the time needed to treat per site was evaluated. RESULTS At 3 months, mean BOP level measured 45.1% at test sites and 50.6% at control sites, respectively, without a statistically significant difference between the groups (P > .05). PPD and CAL slightly improved for both groups with comparable mean values at 3 months. Evaluation of patient tolerance showed statistically significantly better values among patients receiving the test treatment (mean VAS [0-10], 1.51) compared to SRP (mean VAS [0-10], 3.66; P = .0012). The treatment of test sites was set to 5 seconds per site. The treatment of control sites, on the other hand, lasted 85 seconds on average. CONCLUSION The new erythritol powder applied with an air-polishing device can be considered a promising modality for repeated instrumentation of residual pockets during SPT. CLINICAL RELEVANCE With regard to clinical outcomes during SPT, similar results can be expected irrespective of the two treatment approaches of hand instrumentation or subgingival application of erythritol powder with an air-polishing device in sites where only biofilm removal is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this randomized, controlled clinical study was to compare the short-term effects of nonsurgical periodontal therapy with the additional administration of systemic antibiotics (AB) and the same therapy with additional photodynamic therapy (PDT) in the treatment of patients with aggressive periodontitis (AP). Thirty-six patients with AP received full-mouth nonsurgical periodontal treatment (SRP) and were then randomly divided into two groups of 18 subjects each. Group AB received amoxicillin and metronidazole three times a day for 7 days. Group PDT received two applications of PDT on the day of SRP as well as at follow-up after 7 days. The following clinical parameters were measured at baseline and 3 months after therapy: plaque index (PLI), bleeding on probing (BOP), probing depth (PD), gingival recession (GR), and clinical attachment level (CAL). After 3 months, PD was significantly reduced in both groups (from 5.0±0.8 mm to 3.2±0.4 mm with AB, and 5.1±0.5 mm to 4.0±0.8 mm with PDT; both p<0.001), while AB revealed significantly lower values compared to PDT (p = 0.001). In both groups, GR was not significantly changed. CAL was significantly reduced in both groups (PDT: 5.7±0.8 mm to 4.7±1.1 mm; p=0.011; AB: 5.5±1.1 mm to 3.9±1.0 mm; p<0.001) and differed significantly between the groups (p=0.025). The number of residual pockets (PD ≥4 mm) and positive BOP was reduced by AB from 961 to 377, and by PDT from 628 to 394. Pockets with PD ≥7 mm were reduced by AB from 141 to 7, and by PDT from 137 to 61. After 3 months, both treatments led to statistically significant clinical improvements. The systemic administration of antibiotics, however, resulted in significantly higher reduction of PD and a lower number of deep pockets compared to PDT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To clinically evaluate the treatment of Miller Class I and II multiple adjacent gingival recessions using the modified coronally advanced tunnel technique combined with a newly developed bioresorbable collagen matrix of porcine origin. METHOD AND MATERIALS Eight healthy patients exhibiting at least three multiple Miller Class I and II multiple adjacent gingival recessions (a total of 42 recessions) were consecutively treated by means of the modified coronally advanced tunnel technique and collagen matrix. The following clinical parameters were assessed at baseline and 12 months postoperatively: full mouth plaque score (FMPS), full mouth bleeding score (FMBS), probing depth (PD), recession depth (RD), recession width (RW), keratinized tissue thickness (KTT), and keratinized tissue width (KTW). The primary outcome variable was complete root coverage. RESULTS Neither allergic reactions nor soft tissue irritations or matrix exfoliations occurred. Postoperative pain and discomfort were reported to be low, and patient acceptance was generally high. At 12 months, complete root coverage was obtained in 2 out of the 8 patients and 30 of the 42 recessions (71%). CONCLUSION Within their limits, the present results indicate that treatment of Miller Class I and II multiple adjacent gingival recessions by means of the modified coronally advanced tunnel technique and collagen matrix may result in statistically and clinically significant complete root coverage. Further studies are warranted to evaluate the performance of collagen matrix compared with connective tissue grafts and other soft tissue grafts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The purpose of the present study is to evaluate the 10-year results following treatment of intrabony defects treated with an enamel matrix protein derivative (EMD) combined with either a natural bone mineral (NBM) or β-tricalcium phosphate (β-TCP). METHODS Twenty-two patients with advanced chronic periodontitis and displaying one deep intrabony defect were randomly treated with a combination of either EMD + NBM or EMD + β-TCP. Clinical evaluations were performed at baseline and at 1 and 10 years. The following parameters were evaluated: plaque index, bleeding on probing, probing depth, gingival recession, and clinical attachment level (CAL). The primary outcome variable was CAL. RESULTS The defects treated with EMD + NBM demonstrated a mean CAL change from 8.9 ± 1.5 mm to 5.3 ± 0.9 mm (P <0.001) and to 5.8 ± 1.1 mm (P <0.001) at 1 and 10 years, respectively. The sites treated with EMD + β-TCP showed a mean CAL change from 9.1 ± 1.6 mm to 5.4 ± 1.1 mm (P <0.001) at 1 year and 6.1 ± 1.4 mm (P <0.001) at 10 years. At 10 years two defects in the EMD + NBM group had lost 2 mm, whereas two other defects had lost 1 mm of the CAL gained at 1 year. In the EMD + β-TCP group three defects had lost 2 mm, whereas two other defects had lost 1 mm of the CAL gained at 1 year. Compared with baseline, at 10 years, a CAL gain of ≥3 mm was measured in 64% (i.e., seven of 11) of the defects in the EMD + NBM group and in 82% (i.e., nine of 11) of the defects in the EMD + β-TCP group. No statistically significant differences were found between the 1- and 10-year values in either of the two groups. Between the treatment groups, no statistically significant differences in any of the investigated parameters were observed at 1 and 10 years. CONCLUSION Within their limitations, the present findings indicate that the clinical improvements obtained with regenerative surgery using EMD + NBM or EMD + β-TCP can be maintained over a period of 10 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Survival rates in implant dentistry today are high, although late failures do occur for many reasons, including peri-implant infections. The primary objective of this study is to investigate microbiota around single turned implants after 16 to 22 years. Secondary objectives are to compare teeth and implants and to correlate microbiologic, radiographic, and clinical parameters. METHODS A total of 46 patients with single implants were invited for a clinical examination. Clinical data were collected from implants and contralateral natural teeth. Radiographic bone level was measured around implants. Microbiologic samples were taken from implants, contralateral teeth, and the deepest pocket per quadrant. Samples were analyzed with DNA-DNA hybridization including 40 species. Statistical analysis was performed using Wilcoxon signed-rank tests, McNemar tests, and Spearman correlation coefficients with a 0.05 significance level. RESULTS Mean follow-up was 18.5 years (range 16 to 22 years). Tannerella forsythia (1.5 × 10(5)) and Veillonella parvula (1.02 × 10(5)) showed the highest concentrations around implants and teeth, respectively. Porphyromonas gingivalis, Prevotella intermedia, and T. forsythia were significantly more present around implants than teeth. Mean counts were significantly higher around implants than teeth for Parvimonas micra, P. gingivalis, P. intermedia, T. forsythia, and Treponema denticola. Total DNA count was correlated to interproximal bleeding index (r = 0.409) and interproximal probing depth (r = 0.307). No correlations were present with plaque index or radiographic bone level. CONCLUSIONS In the present study, bacterial counts around single implants in periodontally healthy patients are rather low. Although pathogenic bacteria are present, some in higher numbers around implants than teeth (five of 40), the majority of implants present with healthy peri-implant tissues without progressive bone loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. Methods and results: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. Conclusions: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the past five decades, management of acute ST-segment elevation myocardial infarction (STEMI) has evolved substantially. Current treatment encompasses a systematic chain of network activation, antithrombotic drugs, and rapid instigation of mechanical reperfusion, although pharmacoinvasive strategies remain relevant. Secondary prevention with drugs and lifestyle modifications completes the contemporary management package. Despite a tangible improvement in outcomes, STEMI remains a frequent cause of morbidity and mortality, justifying the quest to find new therapeutic avenues. Ways to reduce delays in doing coronary angioplasty after STEMI onset include early recognition of symptoms by patients and prehospital diagnosis by paramedics so that the emergency room can be bypassed in favour of direct admission to the catheterisation laboratory. Mechanical reperfusion can be optimised by improvements to stent design, whereas visualisation of infarct size has been improved by developments in cardiac MRI. Novel treatments to modulate the inflammatory component of atherosclerosis and the vulnerable plaque include use of bioresorbable vascular scaffolds and anti-proliferative drugs. Translational efforts to improve patients' outcomes after STEMI in relation to cardioprotection, cardiac remodelling, and regeneration are also being realised. This is the third in a Series of three papers about ST-segment elevation myocardial infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In patients with dementia, Behavioral and Psychological Symptoms of Dementia (BPSD) are frequent findings that accompany deficits caused by cognitive impairment and thus complicate diagnostics, therapy and care. BPSD are a burden both for affected individuals as well as care-givers, and represent a significant challenge for therapy of a patient population with high degree of multi-morbidity. The goal of this therapy-guideline issued by swiss professional associations is to present guidance regarding therapy of BPSD as attendant symptoms in dementia, based on evidence as well as clinical experience. Here it appears to be of particular importance to take into account professional experience, as at this point for most therapeutic options no sufficiently controlled clinical trials are available. A critical discussion of pharmaco-therapeutic intervention is necessary, as this patient-population is particularly vulnerable for medication side-effects. Finally, a particular emphasis is placed on incorporating and systematically reporting psycho-social and nursing options therapeutic intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM To investigate age- and gender-related differences in non-culprit versus culprit coronary vessels assessed with virtual histology intravascular ultrasound (VH-IVUS). METHODS In 390 patients referred for coronary angiography to a single center (Luzerner Kantonsspital, Switzerland) between May 2007 and January 2011, 691 proximal vessel segments in left anterior descending, circumflex and/or right coronary arteries were imaged by VH-IVUS. Plaque burden and plaque composition (fibrous, fibro-fatty, necrotic core and dense calcium volumes) were analyzed in 3 age tertiles, according to gender and separated for vessels containing non-culprit or culprit lesions. To classify as vessel containing a culprit lesion, the patient had to present with an acute coronary syndrome, and the VH-IVUS had to be performed in a vessel segment containing the culprit lesion according to conventional coronary angiography. RESULTS In non-culprit vessels the plaque burden increased significantly with aging (in men from 37% ± 12% in the lowest to 46% ± 10% in the highest age tertile, P < 0.001; in women from 30% ± 9% to 40% ± 11%, P < 0.001); men had higher plaque burden than women at any age (P < 0.001 for each of the 3 age tertiles). In culprit vessels of the lowest age tertile, plaque burden was significantly higher than that in non-culprit vessels (in men 48% ± 6%, P < 0.001 as compared to non-culprit vessels; in women 44% ± 18%, P = 0.004 as compared to non-culprit vessels). Plaque burden of culprit vessels did not significantly change during aging (plaque burden in men of the highest age tertile 51% ± 9%, P = 0.523 as compared to lowest age tertile; in women of the highest age tertile 49% ± 8%, P = 0.449 as compared to lowest age tertile). In men, plaque morphology of culprit vessels became increasingly rupture-prone during aging (increasing percentages of necrotic core and dense calcium), whereas plaque morphology in non-culprit vessels was less rupture-prone and remained constant during aging. In women, necrotic core in non-culprit vessels was very low at young age, but increased during aging resulting in a plaque morphology that was very similar to men. Plaque morphology in culprit vessels of young women and men was similar. CONCLUSION This study provides evidence that age- and gender-related differences in plaque burden and plaque composition significantly depend on whether the vessel contained a non-culprit or culprit lesion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To investigate the ex vivo performance of high-resolution computed tomography (CT) for quantitative assessment of percentage diameter stenosis in coronary arteries compared to histopathology. MATERIALS AND METHODS High-resolution CT was performed in 26 human heart specimens after the injection of iodinated contrast media into the coronary arteries. Coronary artery plaques were visually identified on CT images and the grade of stenosis for each plaque was measured with electronic calipers. All coronary plaques were characterized by histopathology according to the Stary classification, and the percentage of stenosis was measured. RESULTS CT depicted 84% (274/326) of all coronary plaques identified by histology. Missed plaques by CT were of Stary type I (n=31), type II (n=16), and type III (n=5). The stenosis degree significantly correlated between CT and histology (r=0.81, p<0.001). CT systematically overestimated the stenosis of calcified plaques (mean difference - 11.0 ± 9.5%, p<0.01) and systematically underestimated the stenosis of non-calcified plaques (mean difference -6.8 ± 10.4%, p<0.05), while there was no significant difference for mixed-type plaques (mean difference -0.4 ± 11.7%, p=0.85). There was a significant underestimation of stenosis degree as measured by CT for Stary II plaques (mean difference -14 ± 9%, p<0.01) and a significant overestimation for Stary VII plaques (mean difference 9 ± 10%, p<0.05), but there was no significant difference in stenosis degree between both modalities for other plaque types. CONCLUSIONS High-resolution CT reliably depicts advanced stage coronary plaques with an overall good correlation of stenosis degree compared to histology, however, the degree of stenosis is systematically overestimated in calcified and underestimated in non-calcified plaques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous naturalistic, experimental, and mechanistic studies strongly support the notion that-as part of fight-or-flight response-hemostatic responses to acute psychosocial stress result in net hypercoagulability, which would protect a healthy organism from bleeding in case of injury. Sociodemographic factors, mental states, and comorbidities are important modulators of the acute prothrombotic stress response. In patients with atherosclerosis, exaggerated and prolonged stress-hypercoagulability might accelerate coronary thrombus growth following plaque rupture. Against a background risk from acquired prothrombotic conditions and inherited thrombophilia, acute stress also might trigger venous thromboembolic events. Chronic stressors such as job strain, dementia caregiving, and posttraumatic stress disorder as well as psychological distress from depressive and anxiety symptoms elicit a chronic low-grade hypercoagulable state that is no longer viewed as physiological but might impair vascular health. Through activation of the sympathetic nervous system, higher order cognitive processes and corticolimbic brain areas shape the acute prothrombotic stress response. Hypothalamic-pituitary-adrenal axis and autonomic dysfunction, including vagal withdrawal, are important regulators of hemostatic activity with longer lasting stress. Randomized placebo-controlled trials suggest that several cardiovascular drugs attenuate the acute prothrombotic stress response. Behavioral interventions and psychotropic medications might mitigate chronic low-grade hypercoagulability in stressed individuals, but further studies are clearly needed. Restoring normal hemostatic function with biobehavioral interventions bears the potential to ultimately decrease the risk of thrombotic diseases.