197 resultados para Immediate implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Various imaging techniques, including conventional radiography and computed tomography, are proposed to localize the mandibular canal prior to implant surgery. The aim of this study is to determine the incidence of altered mental nerve sensation after implant placement in the posterior segment of the mandible when a panoramic radiograph is the only preoperative imaging technique used. MATERIAL AND METHODS: The study included 1527 partially and totally edentulous patients who had consecutively received 2584 implants in the posterior segment of the mandible. Preoperative bone height was evaluated from the top of the alveolar crest to the superior border of the mandibular canal on a standard panoramic radiograph. A graduated implant scale from the implant manufacturer was used and 2 mm were subtracted as a safety margin to determine the length of the implant to be inserted. RESULTS: No permanent sensory disturbances of the inferior alveolar nerve were observed. There were two cases of postoperative paresthesia, representing 2/2584 (0.08%) of implants inserted in the posterior segment of the mandible or 2/1527 (0.13%) of patients. These sensory disturbances were minor, lasted for 3 and 6 weeks and resolved spontaneously. CONCLUSIONS: Panoramic examination can be considered a safe preoperative evaluation procedure for routine posterior mandibular implant placement. Panoramic radiography is a quick, simple, low-cost and low-dose presurgical diagnostic tool. When a safety margin of at least 2 mm above the mandibular canal is respected, panoramic radiography appears to be sufficient to evaluate available bone height prior to insertion of posterior mandibular implants; cross-sectional imaging techniques may not be necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In diacetylmorphine prescription programs for heavily dependent addicts, diacetylmorphine is usually administered intravenously, but this may not be possible due to venosclerosis or when heroin abuse had occurred via non-intravenous routes. Since up to 25% of patients administer diacetylmorphine orally, we characterised morphine absorption after single oral doses of immediate and extended release diacetylmorphine in 8 opioid addicts. Plasma concentrations were determined by liquid chromatography-mass spectrometry. Non-compartmental methods and deconvolution were applied for data analysis. Mean (+/-S.D.) immediate and extended release doses were 719+/-297 and 956+/-404 mg, with high absolute morphine bioavailabilities of 56-61%, respectively. Immediate release diacetylmorphine caused rapid morphine absorption, peaking at 10-15 min. Morphine absorption was considerably slower and more sustained for extended release diacetylmorphine, with only approximately 30% of maximal immediate release absorption being reached after 10 min and maintained for 3-4h, with no relevant food interaction. The relative extended to immediate release bioavailability was calculated to be 86% by non-compartmental analysis and 93% by deconvolution analysis. Thus, immediate and extended release diacetylmorphine produce the intended morphine exposures. Both are suitable for substitution treatments. Similar doses can be applied if used in combination or sequentially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The skin is constantly exposed to commensal microflora and pathogenic microbes. The stratum corneum of the outermost skin layer employs distinct tools such as harsh growth conditions and numerous antimicrobial peptides (AMPs) to discriminate between beneficial cutaneous microflora and harmful bacteria. How the skin deals with microbes that have gained access to the live part of the skin as a result of microinjuries is ill defined. In this study, we report that the chemokine CXCL14 is a broad-spectrum AMP with killing activity for cutaneous gram-positive bacteria and Candida albicans as well as the gram-negative enterobacterium Escherichia coli. Based on two separate bacteria-killing assays, CXCL14 compares favorably with other tested AMPs, including human beta-defensin and the chemokine CCL20. Increased salt concentrations and skin-typical pH conditions did not abrogate its AMP function. This novel AMP is highly abundant in the epidermis and dermis of healthy human skin but is down-modulated under conditions of inflammation and disease. We propose that CXCL14 fights bacteria at the earliest stage of infection, well before the establishment of inflammation, and thus fulfills a unique role in antimicrobial immunity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To validate the concept of early implant placement for use in the esthetically sensitive anterior maxilla, clinical trials should ideally include objective esthetic criteria when assessing outcome parameters. METHODS: In this cross-sectional, retrospective 2- to 4-year study involving 45 patients treated with maxillary anterior single-tooth implants according to the concept of early implant placement, a novel comprehensive index, comprising pink esthetic score and white esthetic score (PES/WES; the highest possible combined score is 20), was applied for the objective esthetic outcome assessment of anterior single-tooth implants. RESULTS: All 45 anterior maxillary single-tooth implants fulfilled strict success criteria for dental implants with regard to osseointegration, including the absence of peri-implant radiolucency, implant mobility, suppuration, and pain. The mean total PES/WES was 14.7 +/- 1.18 (range: 11 to 18). The mean total PES of 7.8 +/- 0.88 (range: 6 to 9) documents favorable overall peri-implant soft tissue conditions. The two PES variables facial mucosa curvature (1.9 +/- 0.29) and facial mucosa level (1.8 +/- 0.42) had the highest mean values, whereas the combination variable root convexity/soft tissue color and texture (1.2 +/- 0.53) proved to be the most difficult to fully satisfy. Mean scores were 1.6 +/- 0.5 for the mesial papilla and 1.3 +/- 0.5 for the distal papilla. A mean value of 6.9 +/- 1.47 (range: 4 to 10) was calculated for WES. CONCLUSIONS: This study demonstrated that anterior maxillary single-tooth replacement, according to the concept of early implant placement, is a successful and predictable treatment modality, in general, and from an esthetic point of view, in particular. The suitability of the PES/WES index for the objective outcome assessment of the esthetic dimension of anterior single-tooth implants was confirmed. However, prospective clinical trials are needed to further validate and refine this index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One way to evaluate various implant restorations is to measure the amount of bone change that occurs at the crestal bone. The objective of this study was to histologically evaluate the alveolar bone change around a bone-level, non-matching implant-abutment diameter configuration that incorporated a horizontal offset and a Morse taper internal connection. METHODS: The study design included extraction of all mandibular premolars and first molars in five canines. After 3 months, 12 dental implants were placed at three levels in each dog: even with the alveolar crest, 1 mm above the alveolar crest, and 1 mm below the alveolar crest. The implants were submerged on one side of the mandible. On the other side, healing abutments were exposed to the oral cavity (non-submerged). Gold crowns were attached 2 months after implant placement. The dogs were sacrificed 6 months postloading, and specimens were processed for histologic and histometric analyses. RESULTS: Evaluation of the specimens indicated that the marginal bone remained near the top of the implants under submerged and non-submerged conditions. The amount of bone change for submerged implants placed even with, 1 mm below, and 1 mm above the alveolar crest was -0.34, -1.29, and 0.04 mm, respectively (negative values indicate bone loss). For non-submerged implants, the respective values were -0.38, -1.13, and 0.19 mm. For submerged and non-submerged implants, there were significant differences in the amount of bone change among the three groups (P <0.05). The percentage of bone-to-implant contact for submerged implants was 73.3%, 71.8%, and 71.5%. For non-submerged implants, the respective numbers were 73.2%, 74.5%, and 76%. No significant differences occurred with regard to the percentage of bone contact. CONCLUSIONS: Minimal histologic bone loss occurred when dental implants with non-matching implant-abutment diameters were placed at the bone crest and were loaded for 6 months in the canine. The bone loss was significantly less (five- to six-fold) than that reported for bone-level implants with matching implant-abutment diameters (butt-joint connections).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. MATERIAL AND METHODS: All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. RESULTS: The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. CONCLUSIONS: Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess the bleeding on probing (BOP) tendency and periodontal probe penetration when applying various probing forces at implant sites in patients with a high standard of oral hygiene with well-maintained peri-implant tissues. MATERIAL AND METHODS: Seventeen healthy patients with excellent oral hygiene in a maintenance program after having been treated for periodontitis or gingivitis were recruited. Missing teeth had been replaced using oral implants. The BOP and probing depth (PPD) were assessed at the mid-buccal, mid-oral, mesial and distal aspects of the buccal surfaces of each implant. Moreover, contralateral teeth were designated and assessed for BOP and PPD in the same locations and at the same observation visits. At each visit, implants and contralateral teeth were randomly assigned to one of the standardized probing forces (0.15 or 0.25 N). The second probing force was applied at the repetition of the examination 7 days later. RESULTS: Increasing the probing pressure by 0.1 N from 0.15 N resulted in an increase of BOP percentage by 13.7% and 6.6% for implants and contralateral teeth, respectively. There appeared to be a significant difference of the mean BOP percentage at implant and tooth sites when a probing pressure of 0.25 N was applied. A significantly deeper mean PPD at implant sites compared with tooth sites was found irrespective of the probing pressure applied. CONCLUSIONS: The results of the present study demonstrated that 0.15 N might represent the threshold pressure to be applied to avoid false positive BOP readings around oral implants. Hence, probing around implants demonstrated a higher sensitivity compared with probing around teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate early and immediate loading of implants in the posterior maxilla and to investigate whether there is a difference in success rates, survival rates, and peri-implant parameters, including marginal bone level changes. MATERIALS AND METHODS: A comprehensive systematic review of the literature was conducted. The selection of publications reporting on human clinical studies was based on predetermined inclusion criteria and was agreed upon by two reviewers. RESULTS: Twelve papers were identified on early loading (two randomized controlled clinical trials [RCTs] and 10 prospective case series studies). Six papers were found on immediate loading (one RCT, four prospective case series, and one retrospective study). CONCLUSIONS: Under certain circumstances it is possible to successfully load dental implants in the posterior maxilla early or immediately after their placement in selected patients. The success rate appears to be technique sensitive, although no study has directly assessed this. A high degree of primary implant stability (high value of insertion torque) and implant surface characteristics play an important role. It is not possible to draw evidence-based conclusions concerning contraindications, threshold values for implant stability, bone quality and quantity needed, or impact of occlusal loading forces. As for the impact of the surgical technique on implant outcome in different bone densities, no studies prove significant superior results with one technique over another. Well-designed RCTs with a large number of patients are necessary to make early/immediate loading protocols in posterior maxilla evidence based, but ethical and practical considerations may limit the real possibility of such studies in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical application of ozone gas has been shown to arrest the progression of dentinal caries in children. In this study, we compare the immediate effects of gaseous ozone and chlorhexidine gel on bacteria in cavitated carious lesions in children. Forty children, each with at least two open occlusal carious lesions, were enrolled in the study. Two teeth were chosen randomly. In one lesion, overlying soft biological material was removed, whilst the other lesion was not excavated. Cavities were rinsed with sterile water and dried with air. A standardised sample was taken from the mesial part of each lesion. Then, gaseous ozone (HealOzone) or 1% chlorhexidine gel (Corsodyl) was applied for 30 s on both lesions of 20 children each, and a second sample was taken from the distal part of each lesion. The anaerobic microbiota was cultivated; the number of colony forming units was calculated per milligram sample. The two-sided paired t test showed no significant (P > 0.05) differences in the reduction of total bacterial counts per milligram comparing samples before and after ozone or chlorhexidine application. The tests also showed no statistically significant difference whether the superficial decayed dentine had been removed before ozone or with chlorhexidine treatment or not. It can be concluded that gaseous ozone or chlorhexidine gel application for 30 s to deep occlusal carious cavities had no significant immediate antimicrobial effects whether the superficial decayed layers dentine were removed or not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis of drug allergy involves first the recognition of sometimes unusual symptoms as drug allergy and, second, the identification of the eliciting drug. This is an often difficult task, as the clinical picture and underlying pathomechanisms are heterogeneous. In clinical routine, physicians frequently have to rely upon a suggestive history and eventual provocation tests, both having their specific limitations. For this reason both in vivo (skin tests) and in vitro tests are investigated intensively as tools to identify the disease-eliciting drug. One of the tests evaluated in drug allergy is the basophil activation test (BAT). Basophils with their high-affinity IgE receptors are easily accessible and therefore can be used as indicator cells for IgE-mediated reactions. Upon allergen challenge and cross-linking of membrane-bound IgE antibodies (via Fc-epsilon-RI) basophils up-regulate certain activation markers on their surface such as CD63 and CD203c, as well as intracellular markers (eg, phosphorylated p38MAPK). In BAT, these alterations can be detected rapidly on a single-cell basis by multicolor flow cytometry using specific monoclonal antibodies. Combining this technique with in vitro passive sensitization of donor basophils with patients' serum, one can prove the IgE dependence of a drug reaction. This article summarizes the authors' current experience with the BAT in the diagnostic management of immediate-type drug allergy mediated by drug-specific IgE antibodies.