154 resultados para Heart Septal Defects, Ventricular


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of non-heart-beating donor (NHBD) lungs may help to overcome the shortage of lung grafts in clinical lung transplantation, but warm ischaemia and ischaemia/reperfusion injury (I/R injury) resulting in primary graft dysfunction represent a considerable threat. Thus, better strategies for optimized preservation of lung grafts are urgently needed. Surfactant dysfunction has been shown to contribute to I/R injury, and surfactant replacement therapy is effective in enhancing lung function and structural integrity in related rat models. In the present study we hypothesize that surfactant replacement therapy reduces oedema formation in a pig model of NHBD lung transplantation. Oedema formation was quantified with (SF) and without (non-SF) surfactant replacement therapy in interstitial and alveolar compartments by means of design-based stereology in NHBD lungs 7 h after cardiac arrest, reperfusion and transplantation. A sham-operated group served as control. In both NHBD groups, nearly all animals died within the first hours after transplantation due to right heart failure. Both SF and non-SF developed an interstitial oedema of similar degree, as shown by an increase in septal wall volume and arithmetic mean thickness as well as an increase in the volume of peribron-chovascular connective tissue. Regarding intra-alveolar oedema, no statistically significant difference could be found between SF and non-SF. In conclusion, surfactant replacement therapy cannot prevent poor outcome after prolonged warm ischaemia of 7 h in this model. While the beneficial effects of surfactant replacement therapy have been observed in several experimental and clinical studies related to heart-beating donor lungs and cold ischaemia, it is unlikely that surfactant replacement therapy will overcome the shortage of organs in the context of prolonged warm ischaemia, for example, 7 h. Moreover, our data demonstrate that right heart function and dysfunctions of the pulmonary vascular bed are limiting factors that need to be addressed in NHBD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Heart failure with preserved ejection fraction (HFpEF) is remarkably common in elderly people with highly prevalent comorbid conditions. Despite its increasing in prevalence, there is no evidence-based effective therapy for HFpEF. We sought to evaluate whether inspiratory muscle training (IMT) improves exercise capacity, as well as left ventricular diastolic function, biomarker profile and quality of life (QoL) in patients with advanced HFpEF and nonreduced maximal inspiratory pressure (MIP). DESIGN AND METHODS A total of 26 patients with HFpEF (median (interquartile range) age, peak exercise oxygen uptake (peak VO2) and left ventricular ejection fraction of 73 years (66-76), 10 ml/min/kg (7.6-10.5) and 72% (65-77), respectively) were randomized to receive a 12-week programme of IMT plus standard care vs. standard care alone. The primary endpoint of the study was evaluated by positive changes in cardiopulmonary exercise parameters and distance walked in 6 minutes (6MWT). Secondary endpoints were changes in QoL, echocardiogram parameters of diastolic function, and prognostic biomarkers. RESULTS The IMT group improved significantly their MIP (p < 0.001), peak VO2 (p < 0.001), exercise oxygen uptake at anaerobic threshold (p = 0.001), ventilatory efficiency (p = 0.007), metabolic equivalents (p < 0,001), 6MWT (p < 0.001), and QoL (p = 0.037) as compared to the control group. No changes on diastolic function parameters or biomarkers levels were observed between both groups. CONCLUSIONS In HFpEF patients with low aerobic capacity and non-reduced MIP, IMT was associated with marked improvement in exercise capacity and QoL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. METHODS This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20-29, 30-49, 50-69, and ≥70 years) and cardiac measurements were compared using Pearson's rank correlation over the four different groups. RESULTS With advanced age a slight but significant decrease in ESV (r=-0.41 for both ventricles, P<0.001) and EDV (r=-0.39 for left ventricle, r=-0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). CONCLUSIONS The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tetralogy of Fallot (TOF) is one of the most common congenital heart malformations comprising a ventricular septal defect, right ventricular outflow tract obstruction, right ventricular hypertrophy, and overriding aorta. A rare variant includes pulmonary atresia and major aortopulmonary collateral arteries. Altered hemodynamics within the functional single-ventricle results in turbulent flow and predisposes to endocardial vegetation formation which may consequently lead to thromboembolic events. We present a rare case of an adult survivor of uncorrected TOF with pulmonary atresia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The aim of this study was to determine which single measurement on post-mortem cardiac MR reflects actual heart weight as measured at autopsy, assess the intra- and inter-observer reliability of MR measurements, derive a formula to predict heart weight from MR measurements and test the accuracy of the formula to prospectively predict heart weight. Materials and methods 53 human cadavers underwent post-mortem cardiac MR and forensic autopsy. In Phase 1, left ventricular area and wall thickness were measured on short axis and four chamber view images of 29 cases. All measurements were correlated to heart weight at autopsy using linear regression analysis. In Phase 2, single left ventricular area measurements on four chamber view images (LVA_4C) from 24 cases were used to predict heart weight at autopsy based on equations derived during Phase 1. Intra-class correlation coefficient (ICC) was used to determine inter- and intra-reader agreement. Results Heart weight strongly correlates with LVA_4C (r=0.78 M; p<0.001). Intra-reader and inter-reader reliability was excellent for LVA_4C (ICC=0.81–0.91; p<0.001 and ICC=0.90; p<0.001 respectively). A simplified formula for heart weight ([g]≈LVA_4C [mm2]×0.11) was derived based on linear regression analysis. Conclusions This study shows that single circumferential area measurements of the left ventricle in the four chamber view on post-mortem cardiac MR reflect actual heart weight as measured at autopsy. These measurements yield an excellent intra- and inter-reader reliability and can be used to predict heart weight prior to autopsy or to give a reasonable estimate of heart weight in cases where autopsy is not performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 13-year-old male neutered domestic shorthaired cat had repeated syncopal episodes over a 6 month period, which had variable duration and continued to increase in frequency. Intermittent ventricular asystole, due to complete heart block, and hyperthyroidism were documented. As the syncopal episodes did not respond to a 4-week medical treatment and symptoms became severe, a transvenous ventricular demand pacemaker system (VVIM) was implanted via the external jugular vein. The unipolar lead was tunneled subcutaneously and connected with the generator in a preformed ventral abdominal muscle pocket. During follow up of 18-months there were no recurrences of the syncopal episodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aldosterone plays an important role in the pathophysiology of heart failure. Aldosterone receptor blockade has been shown to reduce morbidity and mortality in human patients with advanced congestive left ventricular heart failure. This study was designed to assess the efficacy and tolerance of long-term low-dose spironolactone when added to conventional heart failure treatment in dogs with advanced heart failure. Eighteen client-owned dogs with advanced congestive heart failure due to either degenerative valve disease (n=11) or dilated cardiomyopathy (n=7) were included in this prospective, placebo-controlled, double-blinded, randomized clinical study. After initial stabilization including furosemide, angiotensin-converting enzyme inhibitors, pimobendan and digoxin, spironolactone at a median dose of 0.52 mg/kg (range 0.49-0.8 mg/kg) once daily (n=9) or placebo (n=9) was added to the treatment, and the dogs were reassessed 3 and 6 months later. Clinical scoring, echocardiography, electrocardiogram, systolic blood pressure measurement, thoracic radiography, sodium, potassium, urea, creatinine, alanine aminotransferase, aldosterone and aminoterminal atrial natriuretic propeptide were assessed at baseline, 3 and 6 months. Survival times were not significantly different between the two treatment groups. Spironolactone was well tolerated when combined with conventional heart failure treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Assist in unison to the patient’s inspiratory neural effort and feedback-controlled limitation of lung distension with neurally adjusted ventilatory assist (NAVA) may reduce the negative effects of mechanical ventilation on right ventricular function. Methods Heart–lung interaction was evaluated in 10 intubated patients with impaired cardiac function using esophageal balloons, pulmonary artery catheters and echocardiography. Adequate NAVA level identified by a titration procedure to breathing pattern (NAVAal), 50% NAVAal, and 200% NAVAal and adequate pressure support (PSVal, defined clinically), 50% PSVal, and 150% PSVal were implemented at constant positive end-expiratory pressure for 20 minutes each. Results NAVAal was 3.1 ± 1.1cmH2O/μV and PSVal was 17 ± 2 cmH20. For all NAVA levels negative esophageal pressure deflections were observed during inspiration whereas this pattern was reversed during PSVal and PSVhigh. As compared to expiration, inspiratory right ventricular outflow tract velocity time integral (surrogating stroke volume) was 103 ± 4%, 109 ± 5%, and 100 ± 4% for NAVAlow, NAVAal, and NAVAhigh and 101 ± 3%, 89 ± 6%, and 83 ± 9% for PSVlow, PSVal, and PSVhigh, respectively (p < 0.001 level-mode interaction, ANOVA). Right ventricular systolic isovolumetric pressure increased from 11.0 ± 4.6 mmHg at PSVlow to 14.0 ± 4.6 mmHg at PSVhigh but remained unchanged (11.5 ± 4.7 mmHg (NAVAlow) and 10.8 ± 4.2 mmHg (NAVAhigh), level-mode interaction p = 0.005). Both indicate progressive right ventricular outflow impedance with increasing pressure support ventilation (PSV), but no change with increasing NAVA level. Conclusions Right ventricular performance is less impaired during NAVA compared to PSV as used in this study. Proposed mechanisms are preservation of cyclic intrathoracic pressure changes characteristic of spontaneous breathing and limitation of right-ventricular outflow impedance during inspiration, regardless of the NAVA level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the introduction of transcatheter structural heart therapies, cardiologists are increasingly aware of the importance of understanding anatomical details of left-sided heart structures. Understanding fluoroscopic cardiac anatomy can facilitate optimal positioning and deployment of prostheses during transcatheter valve repair/replacement, left atrial appendage occlusion, septal defect closure, and paravalvular leak closure. It is possible to use multislice computed tomography to determine optimal fluoroscopic viewing angles for such transcatheter therapies. The purpose of this paper is to describe how optimal fluoroscopic viewing angles of left-sided heart structures can be obtained using computed tomography. Two- and 3-chamber views are described and may become standard in the context of transcatheter structural heart interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Concurrent cardiac diseases are frequent among elderly patients and invite simultaneous treatment to ensure an overall favourable patient outcome. Aim To investigate the feasibility of combined single-session percutaneous cardiac interventions in the era of transcatheter aortic valve implantation (TAVI). Methods This prospective, case–control study included 10 consecutive patients treated with TAVI, left atrial appendage occlusion and percutaneous coronary interventions. Some in addition had patent foramen ovale or atrial septal defect closure in the same session. The patients were matched in a 1:10 manner with TAVI-only cases treated within the same time period at the same institution regarding their baseline factors. The outcome was validated according to the Valve Academic Research Consortium (VARC) criteria. Results Procedural time (126±42 vs 83±40 min, p=0.0016), radiation time (34±8 vs 22±12 min, p=0.0001) and contrast dye (397±89 vs 250±105 mL, p<0.0001) were higher in the combined intervention group than in the TAVI-only group. Despite these drawbacks, no difference in the VARC endpoints was evident during the in-hospital period and after 30 days (VARC combined safety endpoint 32% for TAVI only and 20% for combined intervention, p=1.0). Conclusions Transcatheter treatment of combined cardiac diseases is feasible even in a single session in a high-volume centre with experienced operators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The clinical role of atrial fibrillation/atrial flutter (AF-AFl) and variables predicting these arrhythmias are not well defined in patients with arrhythmogenic right ventricular dysplasia (ARVD). We hypothesized that transthoracic echocardiography (TTE) and 12-lead electrocardiography (ECG) would be helpful in predicting AF-AFl in these patients. METHODS AND RESULTS: ECGs and TTEs of 90 patients diagnosed with definite or borderline ARVD (2010 Task Force Criteria) were analyzed. Data were compared in (1) patients with AF-AFl and (2) all other patients. A total of 18 (20%) patients experienced AF-AFl during a median follow-up of 5.8 years (interquartile range 2.0-10.4). Kaplan-Meier analysis revealed reduced times to AF-AFl among patients with echocardiographic RV fractional area change <27% (P<0.001), left atrial diameter ≥24.4 mm/m(2)(parasternal long-axis, P=0.001), and right atrial short-axis diameter ≥22.1 mm/m(2)(apical 4-chamber view, P=0.05). From all ECG variables, P mitrale conferred the highest hazard ratio (3.37, 95% confidence interval 0.92-12.36, P=0.067). Five patients with AF-AFl experienced inappropriate implantable cardioverter-defibrillator (ICD) shocks compared with 4 without AF-AFl (36% vs. 9%, P=0.03). AF-AFl was more prevalent in heart-transplant patients and those who died of cardiac causes (56% vs. 16%, P=0.014). CONCLUSIONS: AF-AFl is associated with inappropriate ICD shocks, heart transplantation, and cardiac death in patients with ARVD. Evidence of reduced RV function and atrial dilation helps to identify the ARVD patients at increased risk for AF-AFl.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The value of electrocardiographic findings predicting adverse outcome in patients with arrhythmogenic right ventricular dysplasia (ARVD) is not well known. We hypothesized that ventricular depolarization and repolarization abnormalities on the 12-lead surface electrocardiogram (ECG) predict adverse outcome in patients with ARVD. ECGs of 111 patients screened for the 2010 ARVD Task Force Criteria from 3 Swiss tertiary care centers were digitized and analyzed with a digital caliper by 2 independent observers blinded to the outcome. ECGs were compared in 2 patient groups: (1) patients with major adverse cardiovascular events (MACE: a composite of cardiac death, heart transplantation, survived sudden cardiac death, ventricular fibrillation, sustained ventricular tachycardia, or arrhythmic syncope) and (2) all remaining patients. A total of 51 patients (46%) experienced MACE during a follow-up period with median of 4.6 years (interquartile range 1.8 to 10.0). Kaplan-Meier analysis revealed reduced times to MACE for patients with repolarization abnormalities according to Task Force Criteria (p = 0.009), a precordial QRS amplitude ratio (∑QRS mV V1 to V3/∑QRS mV V1 to V6) of ≤ 0.48 (p = 0.019), and QRS fragmentation (p = 0.045). In multivariable Cox regression, a precordial QRS amplitude ratio of ≤ 0.48 (hazard ratio [HR] 2.92, 95% confidence interval [CI] 1.39 to 6.15, p = 0.005), inferior leads T-wave inversions (HR 2.44, 95% CI 1.15 to 5.18, p = 0.020), and QRS fragmentation (HR 2.65, 95% CI 1.1 to 6.34, p = 0.029) remained as independent predictors of MACE. In conclusion, in this multicenter, observational, long-term study, electrocardiographic findings were useful for risk stratification in patients with ARVD, with repolarization criteria, inferior leads TWI, a precordial QRS amplitude ratio of ≤ 0.48, and QRS fragmentation constituting valuable variables to predict adverse outcome.