145 resultados para Endovascular Presence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the risk of shunt-dependent hydrocephalus after treatment of ruptured intracranial aneurysms by clipping versus coiling. METHODS: We analyzed 596 patients prospectively added to our database from July of 1999 to November of 2005 concerning the risk of shunt dependency after clipping versus coiling. Factors analyzed included age; sex; Hunt and Hess grade; Fisher grade; acute hydrocephalus; intraventricular hemorrhage; angiographic vasospasm; and number, size, and location of aneurysms. In addition, a meta-analysis of available data from the literature was performed identifying four studies with quantitative data on the frequency of clip, coil, and shunt dependency. RESULTS: The institutional series revealed Hunt and Hess grade, Fisher grade, acute hydrocephalus, intraventricular hemorrhage, and angiographic vasospasm as significant (P < 0.05) risk factors for shunt dependency after a univariate analysis. In a multivariate logistic regression analysis, we isolated intraventricular hemorrhage, acute hydrocephalus, and angiographic vasospasm as independent, significant risk factors for shunt dependency. The meta-analysis, including the current data, revealed a significantly higher risk for shunt dependency after coiling than after clipping (P = 0.01). CONCLUSION: Clipping of a ruptured aneurysm may be associated with a lower risk for developing shunt dependency, possibly by clot removal. This might influence long-term outcome and surgical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Endovascular repair of the descending thoracic aorta is a very promising technique in elective and, particularly, emergency situations. This study assessed the impact of urgency of the procedure on outcome and mid-term quality of life in surviving patients. METHODS: Post hoc analysis of prospectively collected data of 58 consecutive patients (January 2001-December 2005) with surgical pathologies of the descending thoracic aorta treated by endovascular means. Six patients were excluded due to recent operations on the ascending aorta before thoracic endovascular repair. The remaining patients (n=52) were 69+/-10 years old, and 43 were men (83%). Twenty-seven had been treated electively, and 25 for emergency indications. Reasons for emergency were acute type B aortic dissections with or without malperfusion syndrome in 14, and aortic ruptures in 11 cases. Follow-up was 29+/-16 months. Endpoints were perioperative and late morbidity and mortality rates and long-term quality of life as assessed by the short form health survey (SF-36) and Hospital Anxiety and Depression Scale questionnaires. RESULTS: Cohorts were comparable regarding age, sex, cardiovascular risk factors, and comorbidities. Perioperative mortality was somewhat higher in emergency cases (12% vs 4%, p=0.34). Paraplegia occurred in one patient in each cohort (4%). Overall quality of life after two and a half years was similar in both treatment cohorts: 72 (58-124) after emergency, and 85 (61-105) after elective endovascular aortic repair (p=0.98). Normal scores range from 85 to 115. Anxiety and depression scores were in the normal range and comparable. CONCLUSIONS: Thoracic endovascular aortic repair is an excellent and safe treatment option for the diseased descending aorta, particularly in emergency situations. Early morbidity and mortality rates can be kept very low. Mid-term quality of life was not affected by the urgency of the procedure. Similarly, mid-term anxiety and depression scores were not increased after emergency situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) represents an attractive alternative to open aortic repair (OAR). The aim of this study was to assess outcome and quality of life in patients treated either by TEVAR or OAR for diseased descending thoracic aorta. METHODS: A post hoc analysis of a prospectively collected consecutive series of 136 patients presenting with surgical diseases of the descending aorta between January 2001 and December 2005 was conducted. Fourteen patients were excluded because of involvement of the ascending aorta. Assessed treatment cohorts were TEVAR (n = 52) and OAR (n = 70). Mean follow-up was 34 +/- 18 months. End points were perioperative and late mortality rates and long-term quality of life as assessed by the Short Form Health Survey (SF-36) and Hospital Anxiety and Depression Score questionnaires. RESULTS: Mean age was significantly higher in TEVAR patients (69 +/- 10 years versus 62 +/- 15 years; p = 0.002). Perioperative mortality rates were 9% (OAR) and 8% (TEVAR), respectively (p = 0.254). Accordingly, cumulative long-term mortality rates were similar in both cohorts. Overall quality-of-life scores were 93 (63-110, OAR) and 83 (60-112, TEVAR), respectively. Normal quality-of-life scores range from 85 to 115. Anxiety and depression scores were not increased after open surgery. CONCLUSIONS: Thoracic endovascular aortic repair and OAR both provide excellent long-term results in treatment of thoracic aortic disease. Long-term quality of life, however, is reduced after thoracic aortic repair. Interestingly, TEVAR patients did not score higher in overall quality of life despite all advantages of minimized access trauma. Similarly, anxiety and depression scores are not reduced by TEVAR, possibly reflecting a certain caution against the new technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The traditional approach to stable blunt thoracic aortic injuries (TAI) is immediate repair, with delayed repair reserved for patients with major associated injuries. In recent years, there has been a trend toward delayed repair, even in low-risk patients. This study evaluates the current practices in the surgical community regarding the timing of aortic repair and its effects on outcomes. METHODS: This was a prospective, observational multicenter study sponsored by the American Association for the Surgery of Trauma. The study included patients with blunt TAI scheduled for aortic repair by open or endovascular procedure. Patients in extremis and those managed without aortic repair were excluded. The data collection included demographics, initial clinical presentation, Injury Severity Scores, type and site of aortic injury, type of aortic repair (open or endovascular repair), and time from injury to aortic repair. The study patients were divided into an early repair (< or = 24 hours) and delayed repair groups (> 24 hours). The outcome variables included survival, ventilator days, intensive care unit (ICU) and hospital lengths of stay, blood transfusions, and complications. The outcomes in the two groups were compared with multivariate analysis after adjusting for age, Glasgow Coma Scale, hypotension, major associated injuries, and type of aortic repair. A second multivariate analysis compared outcomes between early and delayed repair, in patients with and patients without major associated injuries. RESULTS: There were 178 patients with TAI eligible for inclusion and analysis, 109 (61.2%) of which underwent early repair and 69 (38.8%) delayed repair. The two groups had similar epidemiologic, injury severity, and type of repair characteristics. The adjusted mortality was significantly higher in the early repair group (adjusted OR [95% CI] 7.78 [1.69-35.70], adjusted p value = 0.008). The adjusted complication rate was similar in the two groups. However, delayed repair was associated with significantly longer ICU and hospital lengths of stay. Analysis of the 108 patients without major associated injuries, adjusting for age, Glasgow Coma Scale, hypotension, and type of aortic repair, showed that in early repair there was a trend toward higher mortality rate (adjusted OR 9.08 [0.88-93.78], adjusted p value = 0.064) but a significantly lower complication rate (adjusted OR 0.4 [0.18-0.96], adjusted p value 0.040) and shorter ICU stay (adjusted p value = 0.021) than the delayed repair group. A similar analysis of the 68 patients with major associated injuries, showed a strong trend toward higher mortality in the early repair group (adjusted OR 9.39 [0.93-95.18], adjusted p value = 0.058). The complication rate was similar in both groups (adjusted p value = 0.239). CONCLUSIONS: Delayed repair of stable blunt TAI is associated with improved survival, irrespective of the presence or not of major associated injuries. However, delayed repair is associated with a longer length of ICU stay and in the group of patients with no major associated injuries a significantly higher complication rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular aneurysm repair has matured significantly over the last 20 years and is becoming increasingly popular as a minimally invasive treatment option for patients with abdominal aortic aneurysms (AAA). Long-term durability of this fascinating treatment, however, is in doubt as continuing aneurysmal degeneration of the aortoiliac graft attachment zones is clearly associated with late adverse sequelae. In recent years, our growing understanding of the physiopathology of AAA formation has facilitated scrutiny of various potential drug treatment concepts. In this article we review the mechanical and biological challenges associated with endovascular treatment of infrarenal AAAs and discuss potential approaches to ongoing aneurysmal degeneration, which hampers long-term outcomes of this minimally invasive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.