127 resultados para Diagnostic Test Accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The choice of imaging techniques in patients with suspected coronary artery disease (CAD) varies between countries, regions, and hospitals. This prospective, multicenter, comparative effectiveness study was designed to assess the relative accuracy of commonly used imaging techniques for identifying patients with significant CAD. METHODS AND RESULTS A total of 475 patients with stable chest pain and intermediate likelihood of CAD underwent coronary computed tomographic angiography and stress myocardial perfusion imaging by single photon emission computed tomography or positron emission tomography, and ventricular wall motion imaging by stress echocardiography or cardiac magnetic resonance. If ≥1 test was abnormal, patients underwent invasive coronary angiography. Significant CAD was defined by invasive coronary angiography as >50% stenosis of the left main stem, >70% stenosis in a major coronary vessel, or 30% to 70% stenosis with fractional flow reserve ≤0.8. Significant CAD was present in 29% of patients. In a patient-based analysis, coronary computed tomographic angiography had the highest diagnostic accuracy, the area under the receiver operating characteristics curve being 0.91 (95% confidence interval, 0.88-0.94), sensitivity being 91%, and specificity being 92%. Myocardial perfusion imaging had good diagnostic accuracy (area under the curve, 0.74; confidence interval, 0.69-0.78), sensitivity 74%, and specificity 73%. Wall motion imaging had similar accuracy (area under the curve, 0.70; confidence interval, 0.65-0.75) but lower sensitivity (49%, P<0.001) and higher specificity (92%, P<0.001). The diagnostic accuracy of myocardial perfusion imaging and wall motion imaging were lower than that of coronary computed tomographic angiography (P<0.001). CONCLUSIONS In a multicenter European population of patients with stable chest pain and low prevalence of CAD, coronary computed tomographic angiography is more accurate than noninvasive functional testing for detecting significant CAD defined invasively. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00979199.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary ciliary dyskinesia is a rare heterogeneous recessive genetic disorder of motile cilia, leading to chronic upper and lower respiratory symptoms. Prevalence is estimated at around 1:10,000, but many patients remain undiagnosed, while others receive the label incorrectly. Proper diagnosis is complicated by the fact that the key symptoms such as wet cough, chronic rhinitis and recurrent upper and lower respiratory infection, are common and nonspecific. There is no single gold standard test to diagnose PCD. Presently, the diagnosis is made by augmenting the medical history and physical examination with in patients with a compatible medical history following a demanding combination of tests including nasal nitric oxide, high- speed video microscopy, transmission electron microscopy, genetics, and ciliary culture. These tests are costly and need sophisticated equipment and experienced staff, restricting use to highly specialised centers. Therefore, it would be desirable to have a screening test for identifying those patients who should undergo detailed diagnostic testing. Three recent studies focused on potential screening tools: one paper assessed the validity of nasal nitric oxide for screening, and two studies developed new symptom-based screening tools. These simple tools are welcome, and hopefully remind physicians whom to refer for definitive testing. However, they have been developed in tertiary care settings, where 10 to 50% of tested patients have PCD. Sensitivity and specificity of the tools are reasonable, but positive and negative predictive values may be poor in primary or secondary care settings. While these studies take an important step forward towards an earlier diagnosis of PCD, more remains to be done before we have tools tailored to different health care settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Symptoms of primary ciliary dyskinesia (PCD) are nonspecific and guidance on whom to refer for testing is limited. Diagnostic tests for PCD are highly specialised, requiring expensive equipment and experienced PCD scientists. This study aims to develop a practical clinical diagnostic tool to identify patients requiring testing.Patients consecutively referred for testing were studied. Information readily obtained from patient history was correlated with diagnostic outcome. Using logistic regression, the predictive performance of the best model was tested by receiver operating characteristic curve analyses. The model was simplified into a practical tool (PICADAR) and externally validated in a second diagnostic centre.Of 641 referrals with a definitive diagnostic outcome, 75 (12%) were positive. PICADAR applies to patients with persistent wet cough and has seven predictive parameters: full-term gestation, neonatal chest symptoms, neonatal intensive care admittance, chronic rhinitis, ear symptoms, situs inversus and congenital cardiac defect. Sensitivity and specificity of the tool were 0.90 and 0.75 for a cut-off score of 5 points. Area under the curve for the internally and externally validated tool was 0.91 and 0.87, respectively.PICADAR represents a simple diagnostic clinical prediction rule with good accuracy and validity, ready for testing in respiratory centres referring to PCD centres.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the case of a patient with a T-lymphoblastic lymphoma whose disseminated mucormycosis was diagnosed with delay, and we address the diagnostic and therapeutic decision-making process and review the diagnostic workup of patients with potential IFD. The diagnosis was delayed despite a suggestive radiological presentation of the patient's pulmonary lesion. The uncommon risk profile (T-lymphoblastic lymphoma, short neutropenic phases) wrongly led to a low level of suspicion. The diagnosis was also hampered by the lack of indirect markers for infections caused by Mucorales, the low sensitivity of both fungal culture and panfungal PCR, and the limited availability of species-specific PCR. A high level of suspicion of IFD is needed, and aggressive diagnostic procedures should be promptly initiated even in apparently low-risk patients with uncommon presentations. The extent of the analytical workup should be decided on a case-by-case base. Diagnostic tests such as the galactomannan and β-D-glucan test and/or PCR on biological material followed by sequencing should be chosen according to their availability and after evaluation of their specificity and sensitivity. In high-risk patients, preemptive therapy with a broad-spectrum mould-active antifungal agent should be started before definitive diagnostic findings become available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Human alveolar (AE) and cystic echinococcosis (CE) caused by the metacestode stages of Echinococcus multilocularis and E. granulosus, respectively, lack pathognomonic clinical signs. Diagnosis therefore relies on the results of imaging and serological studies. The primary goal of this study was to evaluate the efficacy of several easy-to-produce crude or partially purified E. granulosus and E. multilocularis metacestode-derived antigens as tools for the serological diagnosis and differential diagnosis of patients suspicious for AE or CE. METHODS: The sera of 51 treatment-naïve AE and 32 CE patients, 98 Swiss blood donors and 38 patients who were initially suspicious for echinococcosis but suffering from various other liver diseases (e.g., liver neoplasia, etc.) were analysed. RESULTS: According to the results of enzyme-linked immunosorbent assays (ELISA), metacestode-derived antigens of E. granulosus had sensitivities varying from 81 to 97% and >99.9% for the diagnosis of CE and AE, respectively. Antigens derived from E. multilocularis metacestodes had sensitivities ranging from 84 to 91% and >99.9% for the diagnosis of CE and AE, respectively. Specificities ranged from 92 to >99.9%. Post-test probabilities for the differential diagnosis of AE from liver neoplasias, CE from cystic liver lesions, and screening for AE in Switzerland were around 95, 86 and 2.2%, respectively. Cross-reactions with antibodies in sera of patients with other parasitic affections (fasciolosis, schistosomosis, amebosis, cysticercosis, and filarioses) did occur at variable frequencies, but could be eliminated through the use of confirmatory testing. CONCLUSIONS: Different metacestode-derived antigens of E. granulosus and E. multilocularis are valuable, widely accessible, and cost-efficient tools for the serological diagnosis of echinococcosis. However, confirmatory testing is necessary, due to the lack of species specificity and the occurrence of cross-reactions to other helminthic diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Failure of transfer of passive immunity (FTPI) in foals is associated with a risk of infection and death. The current diagnostic gold standard is quantification of immunoglobulins using radial immunodiffusion (IgG-RID). Routine diagnosis is often performed using semi-quantitative tests. Concentrations of serum electrophoretic gamma globulins (EGG) and total globulins may be useful to assess FTPI, but few studies have investigated their use. OBJECTIVES: To assess agreement between IgG-RID and EGG, and evaluate the accuracy of total globulin concentration to diagnose FTPI based on both IgG-RID and EGG. STUDY DESIGN: Prospective study. METHODS: 360 serum samples were harvested at 6-24 hours post natum from 60 German Warmblood foals. Concentrations of EGG, IgG-RID and total globulin concentration (calculated from total proteins and albumin) were measured. Agreement between EGG and IgG-RID was assessed using Bland-Altman plots and Passing-Bablok regression. The accuracy of total globulin concentration was assessed using rank correlation and ROC curve analysis. RESULTS: Good agreement was found with slightly lower EGG than IgG-RID concentrations (Bland-Altman systemic bias, -1.9 g/L) which was more pronounced at higher concentrations (regression equation: IgG-RID = -0.78 +1.28xEGG). Correlations between total globulin concentration and EGG, and total globulin concentration and IgG-RID were 0.93 and 0.79, respectively. The area under the curve was 0.982 and 0.952 for EGG <4 g/L and <8 g/L, and 0.953 and 0.899 for IgG-RID <4 g/L and <8 g/L. Sensitivities and specificities of total globulin concentration in the diagnosis of FTPI were comparable to commonly used screening tests, but cut-offs could be selected to achieve sensitivities of >95% with 71.2% (IgG-RID) and 90.5% (EGG) specificity for <4 g/L, and >90% with 66.0% (IgG-RID) and 87.9% (EGG) specificity for <8 g/L. CONCLUSIONS: There is good agreement between EGG and IgG-RID, with slightly more conservative estimates of immunoglobulins obtained using EGG. Total globulins may be a useful and economic quantitative screening test with cut-offs achieving high sensitivities, but analyser-specific cut-offs may be necessary. This article is protected by copyright. All rights reserved. KEYWORDS: IgG; electrophoresis; foal; globulins; horse; radial immunodiffusion. This article is protected by copyright. All rights reserved.