127 resultados para Case Review
Resumo:
STUDY QUESTION How comprehensive is the recently published European Society of Human Reproduction and Embryology (ESHRE)/European Society for Gynaecological Endoscopy (ESGE) classification system of female genital anomalies? SUMMARY ANSWER The ESHRE/ESGE classification provides a comprehensive description and categorization of almost all of the currently known anomalies that could not be classified properly with the American Fertility Society (AFS) system. WHAT IS KNOWN ALREADY Until now, the more accepted classification system, namely that of the AFS, is associated with serious limitations in effective categorization of female genital anomalies. Many cases published in the literature could not be properly classified using the AFS system, yet a clear and accurate classification is a prerequisite for treatment. STUDY DESIGN, SIZE AND DURATION The CONUTA (CONgenital UTerine Anomalies) ESHRE/ESGE group conducted a systematic review of the literature to examine if those types of anomalies that could not be properly classified with the AFS system could be effectively classified with the use of the new ESHRE/ESGE system. An electronic literature search through Medline, Embase and Cochrane library was carried out from January 1988 to January 2014. Three participants independently screened, selected articles of potential interest and finally extracted data from all the included studies. Any disagreement was discussed and resolved after consultation with a fourth reviewer and the results were assessed independently and approved by all members of the CONUTA group. PARTICIPANTS/MATERIALS, SETTING, METHODS Among the 143 articles assessed in detail, 120 were finally selected reporting 140 cases that could not properly fit into a specific class of the AFS system. Those 140 cases were clustered in 39 different types of anomalies. MAIN RESULTS AND THE ROLE OF CHANCE The congenital anomaly involved a single organ in 12 (30.8%) out of the 39 types of anomalies, while multiple organs and/or segments of Müllerian ducts (complex anomaly) were involved in 27 (69.2%) types. Uterus was the organ most frequently involved (30/39: 76.9%), followed by cervix (26/39: 66.7%) and vagina (23/39: 59%). In all 39 types, the ESHRE/ESGE classification system provided a comprehensive description of each single or complex anomaly. A precise categorization was reached in 38 out of 39 types studied. Only one case of a bizarre uterine anomaly, with no clear embryological defect, could not be categorized and thus was placed in Class 6 (un-classified) of the ESHRE/ESGE system. LIMITATIONS, REASONS FOR CAUTION The review of the literature was thorough but we cannot rule out the possibility that other defects exist which will also require testing in the new ESHRE/ESGE system. These anomalies, however, must be rare. WIDER IMPLICATIONS OF THE FINDINGS The comprehensiveness of the ESHRE/ESGE classification adds objective scientific validity to its use. This may, therefore, promote its further dissemination and acceptance, which will have a positive outcome in clinical care and research. STUDY FUNDING/COMPETING INTERESTS None.
Resumo:
OBJECTIVE The improvement in diagnostic accuracy and optimization of treatment planning in periodontology through the use of three-dimensional imaging with cone beam computed tomography (CBCT) is discussed controversially in the literature. The objective was to identify the best available external evidence for the indications of CBCT for periodontal diagnosis and treatment planning in specific clinical situations. DATA SOURCES A systematic literature search was performed for articles published by 2 March 2015 using electronic databases and hand search. Two reviewers performed the study selection, data collection, and validity assessment. PICO and PRISMA criteria were applied. From the combined search, seven studies were finally included. CONCLUSION The case series were published from the years 2009 to 2014. Five of the included publications refer to maxillary and/or mandibular molars and two to aspects related to vertical bony defects. Two studies show a high accuracy of CBCT in detecting intrabony defect morphology when compared to periapical radiographs. Particularly, in maxillary molars, CBCT provides high accuracy for detecting furcation involvement and morphology of surrounding periodontal tissues. CBCT has demonstrated advantages, when more invasive treatment approaches were considered in terms of decision making and cost benefit. Within their limits, the available data suggest that CBCT may improve diagnostic accuracy and optimize treatment planning in periodontal defects, particularly in maxillary molars with furcation involvement, and that the higher irradiation doses and cost-benefit ratio should be carefully analyzed before using CBCT for periodontal diagnosis and treatment planning.
Resumo:
CONTEXT Tibial nerve stimulation (TNS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option for patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TNS for treating neurogenic lower urinary tract dysfunction (NLUTD). EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 16 studies (4 randomized controlled trials [RCTs], 9 prospective cohort studies, 2 retrospective case series, and 1 case report) enrolling 469 patients (283 women and 186 men) were included. Five studies reported on acute TNS and 11 on chronic TNS. In acute and chronic TNS, the mean increase of maximum cystometric capacity ranged from 56 to 132mL and from 49 to 150mL, and the mean increase of bladder volume at first detrusor overactivity ranged from 44 to 92mL and from 93 to 121mL, respectively. In acute and chronic TNS, the mean decrease of maximum detrusor pressure during the storage phase ranged from 5 to 15cm H2O and from 4 to 21cm H2O, respectively. In chronic TNS, the mean decrease in number of voids per 24h, in number of leakages per 24h, and in postvoid residual ranged from 3 to 7, from 1 to 4, and from 15 to 55mL, respectively. No TNS-related adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data of RCTs and non-RCTs suggest TNS might be effective and safe for treating NLUTD, the evidence base is poor, derived from small, mostly noncomparative studies with a high risk of bias and confounding. More reliable data from well-designed RCTs are needed to reach definitive conclusions. PATIENT SUMMARY Early data suggest tibial nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.
Resumo:
CONTEXT Transcutaneous electrical nerve stimulation (TENS) is a promising therapy for non-neurogenic lower urinary tract dysfunction and might also be a valuable option in patients with an underlying neurological disorder. OBJECTIVE We systematically reviewed all available evidence on the efficacy and safety of TENS for treating neurogenic lower urinary tract dysfunction. EVIDENCE ACQUISITION The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement. EVIDENCE SYNTHESIS After screening 1943 articles, 22 studies (two randomised controlled trials, 14 prospective cohort studies, five retrospective case series, and one case report) enrolling 450 patients were included. Eleven studies reported on acute TENS and 11 on chronic TENS. In acute TENS and chronic TENS, the mean increase of maximum cystometric capacity ranged from 69ml to 163ml and from 4ml to 156ml, the mean change of bladder volume at first detrusor overactivity from a decrease of 13ml to an increase of 175ml and from an increase of 10ml to 120ml, a mean decrease of maximum detrusor pressure at first detrusor overactivity from 18 cmH20 to 72 cmH20 and 8 cmH20, and a mean decrease of maximum storage detrusor pressure from 20 cmH20 to 58 cmH2O and from 3 cmH20 to 8 cmH2O, respectively. In chronic TENS, a mean decrease in the number of voids and leakages per 24h ranged from 1 to 3 and from 0 to 4, a mean increase of maximum flow rate from 2ml/s to 7ml/s, and a mean change of postvoid residual from an increase of 26ml to a decrease of 85ml. No TENS-related serious adverse events have been reported. Risk of bias and confounding was high in most studies. CONCLUSIONS Although preliminary data suggest TENS might be effective and safe for treating neurogenic lower urinary tract dysfunction, the evidence base is poor and more reliable data from well-designed randomised controlled trials are needed to make definitive conclusions. PATIENT SUMMARY Early data suggest that transcutaneous electrical nerve stimulation might be effective and safe for treating neurogenic lower urinary tract dysfunction, but more reliable evidence is required.
Resumo:
Governance of food systems is a poorly understood determinant of food security. Much scholarship on food systems governance is non-empirical, while existing research is often case study-based and theoretically and methodologically incommensurable. This frustrates aggregation of evidence and generalisation. We undertook a systematic review of methods used in food systems governance research with a view to identifying a core set of indicators for future research. We gathered literature through a structured consultation and sampling from recent reviews. Indicators were identified and classified according to the levels and sectors they investigate. We found a concentration of indicators in food production at local to national levels and a sparseness in distribution and consumption. Unsurprisingly, many indicators of institutional structure were found, while agency-related indicators are moderately represented. We call for piloting and validation of these indicators and for methodological development to fill gaps identified. These efforts are expected to support a more consolidated future evidence base and eventual meta-analysis.
Resumo:
The reclamation, treatment and reuse of municipal wastewater can provide important environmental benefits. In this paper, 25 studies on this topic were reviewed and it was found that there are many (\textgreater150) different drivers acting for and against wastewater recycling. To deal with the challenge of comparing studies which entailed different research designs, a framework was developed which allowed the literature to be organized into comparable study contexts. Studies were categorized according to the level of analysis (wastewater recycling scheme, city, water utility, state, country, global) and outcome investigated (development/investment in new schemes, program implementation, percentage of wastewater recycled, percentage of water demand covered by recycled water, multiple outcomes). Findings across comparable case studies were then grouped according to the type (for or against recycling) and category of driver (social, natural, technical, economic, policy or business). The utility of the framework is demonstrated by summarizing the findings from four Australian studies at the city level. The framework offers a unique approach for disentangling the broad range of potential drivers for and against water recycling and to focus on those that seem relevant in specific study contexts. It may offer a valuable starting point for building hypotheses in future work.
Resumo:
BACKGROUND Extracorporeal membrane oxygenation (ECMO) offers therapeutic options in refractory respiratory and/or cardiac failure. Systemic anticoagulation with heparin is routinely administered. However, in patients with heparin-induced thrombocytopenia or heparin resistance, the direct thrombin inhibitor bivalirudin is a valid option and has been increasingly used for ECMO anticoagulation. We aimed at evaluating its safety and its optimal dosing for ECMO. METHODS Systematic web-based literature search of PubMed and EMBASE performed via National Health Service Library Evidence and manually, updated until January 30, 2016. RESULTS The search revealed 8 publications relevant to the topic (5 case reports). In total, 58 patients (24 pediatrics) were reported (18 received heparin as control groups). Bivalirudin was used with or without loading dose, followed by infusion at different ranges (lowest 0.1-0.2 mg/kg/h without loading dose; highest 0.5 mg/kg/h after loading dose). The strategies for monitoring anticoagulation and optimal targets were dissimilar (activated partial thromboplastin time 45-60 seconds to 42-88 seconds; activated clotting time 180-200 seconds to 200-220 seconds; thromboelastography in 1 study). CONCLUSION Bivalirudin loading dose was not always used; infusion range and anticoagulation targets were different. In this systematic review, we discuss the reasons for this variability. Larger studies are needed to establish the optimal approach with the use of bivalirudin for ECMO.