238 resultados para COCHLEAR IMPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: We sought to investigate the prevalence of posttraumatic stress disorder, anxiety, and depression in patients and their partners after implantation of a mechanical assist device as a bridge to heart transplantation. METHODS: This was a retrospective assessment of 41 patients (age 46.3 +/- 12.0 years; male-female ratio, 38:3; time since transplantation, 55.3 +/- 34.2 months [range, 7-122 months) and 27 partners (male-female ratio 2:25) by standardized instruments (Impact of Event Scale, Hospital Anxiety and Depression Scale), in 2 University Heart Transplant Centers (Vienna, Austria, Munster, Germany). The duration of the support systems (MicroMed DeBakey-VAD in 17 patients, Novacor in 10, Thoratec in 8, TCI HeartMate in 5, and Berlin Heart Incor in 1 patient) ranged from 28 to 711 (176 +/- 146) days. RESULTS: None of the patients, but 23% of the partners (n = 6), met the criteria for posttraumatic stress disorder (Maercker cutoff >0). The Impact of Event Scale (IES) sum scales differed significantly between the 2 groups (21.2 +/- 15.1, mean +/- SD) for the patients versus 38.1 +/- 27.8 for the partners, respectively; P = .001). Two percent of the patients, but 19% of the partners, showed mild to moderate depression; 4% of patients, but 23% of their partners, reported mild to moderate anxiety. None of the results were significantly influenced by the time since transplantation, patient age, diagnoses, type of assist device, or indication for heart transplantation. CONCLUSIONS: Despite patients being much closer to a life threat, their partners experience significantly more psychologic distress even in the long run. Our findings highlight the need for attention to the supporting persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Recent studies of drug-eluting stents for unprotected left main coronary artery (LMCA) disease have been encouraging. We examined the performance of sirolimus-eluting stents (SES) for this indication. METHODS AND RESULTS: This retrospective study included 228 consecutive patients (mean age = 68 +/- 11 years, 80.6% men, 26.3% diabetics) who underwent implantation of SES for de novo LMCA stenoses. The mean additive and logistic EuroSCOREs were 5.2 +/- 3.9 and 8.2 +/- 13.2, respectively. The main objective of this study was to measure the rate of major adverse cardiac events (MACE), including death, myocardial infarction and target lesion revascularisation (TLR) at 12 months. Other objectives were to measure the rates of in-hospital MACE and 12-month TLR. Outcomes in 143 patients with (BIF+ group), versus 84 patients without (BIF-group) involvement of the bifurcation were compared. The pre-procedural percent diameter stenosis (%DS) was 60.1 +/- 11.2 in the BIF+ versus 54.7 +/- 12.2% in the BIF- group (p=0.008), and decreased to 18.0 +/- 9.7 and 13.9 +/- 11.3%, respectively (ns), after SES implant. The overall in-hospital MACE rate was 3.5%, and similar in both subgroups. The 1-year MACE rate was 14.5% overall, 16.8% in the BIF+ and 10.7% in the BIF- subgroup (ns). CONCLUSIONS: SES implants in high-risk patients with LMCA stenoses were associated with a low 1-year MACE rate. Stenting of the bifurcation was associated with significant increases in neither mortality nor 1-year MACE rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to investigate the long-term safety and efficacy of percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation for unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Long-term clinical outcomes after DES implantation for ULMCA disease have not yet been ascertained. METHODS: From April 2002 to April 2004, 358 consecutive patients who underwent PCI with DES implantation for de novo lesions on ULMCA were retrospectively selected and analyzed in 7 European and U.S. tertiary care centers. No patients were excluded from the analysis, and all patients had a minimum follow-up of 3 years. RESULTS: Technical success rate was 100%. Procedural success rate was 89.6%. After 3 years, major adverse cardiovascular events (MACE)-free survival in the whole population was 73.5%. According to the Academic Research Consortium definitions, cardiac death occurred in 9.2% of patients, and reinfarction, target lesion revascularization (TLR), and target vessel revascularization (TVR) occurred in 8.6%, 5.8%, and 14.2% of patients, respectively. Definite stent thrombosis occurred in 2 patients (specifically at 0 and 439 days). In elective patients, the 3-year MACE-free survival was 74.2%, with mortality, reinfarction, TLR, and TVR rates of 6.2%, 8.3%, 6.6%, and 16%, respectively. In the emergent group the 3-year MACE-free survival was 68.2%, with mortality, reinfarction, TLR, and TVR rates of 21.4%, 10%, 2.8%, and 7.1%, respectively. CONCLUSIONS: Routine DES implantation in ULMCA disease seems encouraging, with favorable long-term clinical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical value of early exercise stress testing (EST) after coronary stenting to predict long-term clinical outcomes is unknown. Of 1,000 unselected patients who underwent coronary stenting, 446 random patients underwent early EST the day after intervention. Clinical long-term outcomes (41 +/- 20 months) were correlated with normal (n = 314 [70%]) or positive (n = 102 [23%]) EST results. Patients with inconclusive test results (n = 30 [7%]) were excluded from the analysis. Overall mortality was significantly higher in patients with positive EST results (9.3% vs 3.9%, p = 0.04). Major adverse cardiac events and cardiac mortality also tended to be higher in patients with positive stress test results (45.4% vs 35.4%, p = 0.08, and 4.1% vs 1.1%, p = 0.05, respectively). Patients with the combination of positive stress test results and incomplete revascularization appeared to be the group at highest risk for major adverse cardiac events (47.1% vs 33.3% for patients with normal stress test results and complete revascularization, p = NS). Negative stress test results reduced (odds ratio 0.329, 95% confidence interval 0.120 to 0.905, p = 0.031) and a lower ejection fraction increased (odds ratio 0.942, 95% confidence interval 0.897 to 0.989, p = 0.017) the risk for death. In conclusion, an early stress test after coronary stenting provides important prognostic information. Positive stress test results, especially in combination with incomplete revascularization, are associated with higher mortality, a trend toward more repeat revascularization procedures, and higher risk for major adverse cardiac events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotational atherectomy has been regaining interest over the last couple of years after it almost has disappeared from most interventional catheterization laboratories for several years due to failure to prove its original concept of improving long term results of percutaneous coronary interventions (PCI) as was repeatedly shown in studies in the 1990s. Its revival coupled the introduction of drug-eluting stents (DES); these devices have led to treating much more complex lesions and high-risk patients by PCI. However, real-world experience suggested that off-label use of DES is associated with a higher rate of early and late stent thrombosis. Therefore, more attention is now being paid to the initial implantation technique of DES including aggressive lesion preparation to facilitate stent delivery and expansion. The limited studies with rot-ablation and DES showed promising results with no long term safety concerns. In these studies, a subtle observation was made suggesting that rot-ablation prior to DES implantation in such lesions may have an add-on effect on long term outcome compared to DES alone. An ongoing multicenter study is investigating such effect among complex calcified coronary lesions. Even if this additive benefit does not prove true, rot-ablation remains an efficient tool for preparing certain lesions to facilitate effective and safe DES implantation. Therefore, interventional training programs should focus on this difficult technique to bridge the gap of experience which resulted from neglecting it for several years. In this regard, dedicated courses at experienced sites as well as medical simulation may be appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To examine the ambiguity tolerance, i.e. the ability to perceive new, contradictory and complex situations as positive challenges, of pre-lingually deafened adolescents who received a cochlear implant after their eighth birthday and to identify those dimensions of ambiguity tolerance which correlate significantly with specific variables of their oral communication. DESIGN AND SETTING: Clinical survey at an academic tertiary referral center. Participants and main outcome measures: A questionnaire concerning communication and subjectively perceived changes compared to the pre-cochlear implant situation was completed by 13 pre-lingually deafened patients aged between 13 and 23 years, who received their cochlear implants between the ages of 8 and 17 years. The results were correlated with the 'Inventory for Measuring Ambiguity Tolerance'. RESULTS: The patients showed a lower ambiguity tolerance with a total score of 134.5 than the normative group with a score of 143.1. There was a positive correlation between the total score for ambiguity tolerance and the frequency of 'use of oral speech', as well as between the subscale 'ambiguity tolerance towards apparently insoluble problems' and all five areas of oral communication that were investigated. Comparison of two variables of oral communication, which shows a significant difference pre- and postoperatively, yields a positive correlation with the subscale 'ambiguity tolerance towards the parental image'. CONCLUSIONS: Pre-lingually deafened juveniles with cochlear implant who increasingly use oral communication seem to regard the limits of a cochlear implant as an interesting challenge rather than an insoluble problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.