181 resultados para Bilateral balanced occlusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Treatment strategies for acute basilar artery occlusion (BAO) are based on case series and data that have been extrapolated from stroke intervention trials in other cerebrovascular territories, and information on the efficacy of different treatments in unselected patients with BAO is scarce. We therefore assessed outcomes and differences in treatment response after BAO. METHODS: The Basilar Artery International Cooperation Study (BASICS) is a prospective, observational registry of consecutive patients who presented with an acute symptomatic and radiologically confirmed BAO between November 1, 2002, and October 1, 2007. Stroke severity at time of treatment was dichotomised as severe (coma, locked-in state, or tetraplegia) or mild to moderate (any deficit that was less than severe). Outcome was assessed at 1 month. Poor outcome was defined as a modified Rankin scale score of 4 or 5, or death. Patients were divided into three groups according to the treatment they received: antithrombotic treatment only (AT), which comprised antiplatelet drugs or systemic anticoagulation; primary intravenous thrombolysis (IVT), including subsequent intra-arterial thrombolysis; or intra-arterial therapy (IAT), which comprised thrombolysis, mechanical thrombectomy, stenting, or a combination of these approaches. Risk ratios (RR) for treatment effects were adjusted for age, the severity of neurological deficits at the time of treatment, time to treatment, prodromal minor stroke, location of the occlusion, and diabetes. FINDINGS: 619 patients were entered in the registry. 27 patients were excluded from the analyses because they did not receive AT, IVT, or IAT, and all had a poor outcome. Of the 592 patients who were analysed, 183 were treated with only AT, 121 with IVT, and 288 with IAT. Overall, 402 (68%) of the analysed patients had a poor outcome. No statistically significant superiority was found for any treatment strategy. Compared with outcome after AT, patients with a mild-to-moderate deficit (n=245) had about the same risk of poor outcome after IVT (adjusted RR 0.94, 95% CI 0.60-1.45) or after IAT (adjusted RR 1.29, 0.97-1.72) but had a worse outcome after IAT compared with IVT (adjusted RR 1.49, 1.00-2.23). Compared with AT, patients with a severe deficit (n=347) had a lower risk of poor outcome after IVT (adjusted RR 0.88, 0.76-1.01) or IAT (adjusted RR 0.94, 0.86-1.02), whereas outcomes were similar after treatment with IAT or IVT (adjusted RR 1.06, 0.91-1.22). INTERPRETATION: Most patients in the BASICS registry received IAT. Our results do not support unequivocal superiority of IAT over IVT, and the efficacy of IAT versus IVT in patients with an acute BAO needs to be assessed in a randomised controlled trial. FUNDING: Department of Neurology, University Medical Center Utrecht.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exact mechanism for capillary occlusion in diabetic retinopathy is still unclear, but increased leukocyte-endothelial cell adhesion has been implicated. We examined the possibility that posttranslational modification of surface O-glycans by increased activity of core 2 transferase (UDP-Glc:Galbeta1-3GalNAcalphaRbeta-N-acetylglucoaminyltr ansferase) is responsible for increased adhesion of leukocytes to vascular endothelium in diabetes. The mean activity of core 2 transferase in polymorphonuclear leukocytes isolated from type 1 and type 2 diabetic patients was higher compared with age-matched control subjects (1,638 +/- 91 [n = 42] vs. 249 +/- 35 pmol x h(-1) x mg(-1) protein [n = 24], P = 0.00013; 1,459 +/- 194 [n = 58] vs. 334 +/- 86 [n = 11], P = 0.01). As a group, diabetic patients with retinopathy had significantly higher mean activity of core 2 transferase compared with individuals with no retinopathy. There was a significant association between enzyme activity and severity of retinopathy in type 1 and type 2 diabetic patients. There was a strong correlation between activity of core 2 transferase and extent of leukocyte adhesion to cultured retinal capillary endothelial cells for diabetic patients but not for age-matched control subjects. Results from transfection experiments using human myelocytic cell line (U937) demonstrated a direct relationship between increased activity of core 2 transferase and increased binding to cultured endothelial cells. There was no relationship between activity of core 2 transferase and HbA(1c) (P = 0.8314), serum advanced glycation end product levels (P = 0.4159), age of the patient (P = 0.7896), and duration of diabetes (P = 0.3307). On the basis that branched O-glycans formed by the action of core 2 transferase participate in leukocyte adhesion, the present data suggest the involvement of this enzyme in increased leukocyte-endothelial cell adhesion and the pathogenesis of capillary occlusion in diabetic retinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a 36-year-old man with a history of mild head trauma. The initial clinical findings and the CT-scan of the brain revealed no pathological result, although the patient suffered from weakness of the right arm and bilateral blindness. Those findings were interpreted as psychogenic disorder. Nine days later he developed an instable gait, a child like attitude, amnesia and enuresis. The CT-scan revealed a subacute bilateral occipital stroke in the region of the arteriae cerebri posteriors. No cause for the stroke was found. In spite of the rareness of cortical blindness in young people as a cause of stroke, a detailed medical history and clinical examination should always be performed, and by unclearness additional investigations should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note, we show that an extension of a test for perfect ranking in a balanced ranked set sample given by Li and Balakrishnan (2008) to the multi-cycle case turns out to be equivalent to the test statistic proposed by Frey et al. (2007). This provides an alternative interpretation and motivation for their test statistic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND Intermediate-term outcome data following LAA occlusion are scarce. METHODS Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. Background: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case of atrial tachycardia 2 years after pulmonary transplantation. After excluding right atrial involvement, tachycardia origin was located in a scar region medial to the anastomosis of the left inferior pulmonary donor vein. Tachycardia mechanism was microreentry. Noninvasive electrocardiographic mapping performed before the ablation procedure matched with results of invasive Carto mapping and predicted both tachycardia mechanism and origin. We discuss arrhythmia mechanism found after pulmonary transplantation and benefit of noninvasive electrocardiographic mapping for procedure planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To report a case of bilateral acute anterior uveitis in association with the application of an analgesic transdermal capsaicin patch. METHODS Case report and review of literature. RESULTS A 38-year-old woman suffered from bilateral acute anterior uveitis, manifesting 12-24 h after application of an analgesic capsaicin patch (Isola Capsicum N Plus) that served to alleviate muscular neck pain. Systemic immune-mediated and infectious diseases were excluded by medical history and laboratory testing. Control of inflammation was achieved with topical corticosteroid treatment within 1 week. Over the course of a 1-year follow-up, no further recurrence of uveitis was observed. CONCLUSIONS The case suggests a possible association of capsaicin-containing transdermal patches and acute anterior uveitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.