154 resultados para Advanced Very High Resolution Radiometer (AVHRR)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution capillary zone electrophoresis in the routine arena with stringent quality assurance is employed for the determination of carbohydrate-deficient transferrin in human serum. The assay comprises mixing of human serum with a Fe(III) -containing solution prior to analysis of the iron-saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. In contrast to other assays, it provides sufficient resolution for proper recognition of genetic transferrin variants. Analysis of 7290 patient sera revealed 166 isoform patterns that could be assigned to genetic variants, namely, 109 BC, 53 CD, one BD and three CC variants. Several subtypes of transferrin D can be distinguished as they have large enough differences in pI values. Subtypes of transferrin C and B cannot be resolved. However, analysis of the detection time ratios of tetrasialo isoforms of transferrin BC and transferrin CD variants revealed multimodal frequency histograms, indicating the presence of subtypes of transferrin C, B and D. The data gathered over 11 years demonstrate the robustness of the high-resolution capillary zone electrophoresis assay. This is the first account of a capillary zone electrophoresis based carbohydrate-deficient transferrin assay with a broad overview on transferrin isoform patterns associated with genetic transferrin variants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of initial sample distribution on separation and focusing of analytes in a pH 3–11 gradient formed by 101 biprotic carrier ampholytes under concomitant electroosmotic displacement was studied by dynamic high-resolution computer simulation. Data obtained with application of the analytes mixed with the carrier ampholytes (as is customarily done), as a short zone within the initial carrier ampholyte zone, sandwiched between zones of carrier ampholytes, or introduced before or after the initial carrier ampholyte zone were compared. With sampling as a short zone within or adjacent to the carrier ampholytes, separation and focusing of analytes is shown to proceed as a cationic, anionic, or mixed process and separation of the analytes is predicted to be much faster than the separation of the carrier components. Thus, after the initial separation, analytes continue to separate and eventually reach their focusing locations. This is different to the double-peak approach to equilibrium that takes place when analytes and carrier ampholytes are applied as a homogenous mixture. Simulation data reveal that sample application between two zones of carrier ampholytes results in the formation of a pH gradient disturbance as the concentration of the carrier ampholytes within the fluid element initially occupied by the sample will be lower compared to the other parts of the gradient. As a consequence thereof, the properties of this region are sample matrix dependent, the pH gradient is flatter, and the region is likely to represent a conductance gap (hot spot). Simulation data suggest that sample placed at the anodic side or at the anodic end of the initial carrier ampholyte zone are the favorable configurations for capillary isoelectric focusing with electroosmotic zone mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GENTRANS, a comprehensive one-dimensional dynamic simulator for electrophoretic separations and transport, was extended for handling electrokinetic chiral separations with a neutral ligand. The code can be employed to study the 1:1 interaction of monovalent weak and strong acids and bases with a single monovalent weak or strong acid or base additive, including a neutral cyclodextrin, under real experimental conditions. It is a tool to investigate the dynamics of chiral separations and to provide insight into the buffer systems used in chiral capillary zone electrophoresis (CZE) and chiral isotachophoresis. Analyte stacking across conductivity and buffer additive gradients, changes of additive concentration, buffer component concentration, pH, and conductivity across migrating sample zones and peaks, and the formation and migration of system peaks can thereby be investigated in a hitherto inaccessible way. For model systems with charged weak bases and neutral modified β-cyclodextrins at acidic pH, for which complexation constants, ionic mobilities, and mobilities of selector-analyte complexes have been determined by CZE, simulated and experimentally determined electropherograms and isotachopherograms are shown to be in good agreement. Simulation data reveal that CZE separations of cationic enantiomers performed in phosphate buffers at low pH occur behind a fast cationic migrating system peak that has a small impact on the buffer composition under which enantiomeric separation takes place.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present an image quality assessment and enhancement method for high-resolution Fourier-Domain OCT imaging like in sub-threshold retina therapy. A Maximum-Likelihood deconvolution algorithm as well as a histogram-based quality assessment method are evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peat deposits from an ombrotrophic bog (north-eastern Poland) were analysed to reconstruct peatland development and environmental changes. This paper presents reconstructions of hydrological changes and plant succession over the last 6000 years. The methods included the high-resolution analysis of plant macrofossils, pollen and testate amoebae, supported by radiocarbon dating. Three main phases were identified in the history of the bog and surrounding woodland vegetation: 4000–400 BC, 400 BC–AD 1700 and AD 1700–2011. Except for terrestrialisation and the fen-to-bog transition phase, the development of bog vegetation was mainly dependent on the climate until approximately AD 1700. The dominant taxon in Gązwa bog was Sphagnum fuscum/rubellum. Woodland development was significantly affected by human activity at several time periods. The most visible human activity, manifested by the decline of deciduous species, occurred ca. 350 BC, ca. AD 250, ca. AD 1350 and after AD 1700. These events correspond to phases of human settlement in the area. During 400–300 BC, the decline of deciduous trees, primarily Carpinus, coincided with an increase in indicators of human activity and fire frequency. At ca. AD 200, Carpinus and Tilia abundance decreased, corresponding to an increased importance of cereals (Secale and Triticum). Since ca. AD 1350, the impact of Teutonic settlement is apparent, and after AD 1700, deciduous forests largely disappeared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The value of radical prostatectomy (RP) as an approach for very high-risk prostate cancer (PCa) patients is controversial. To examine the risk of 10-year cancer-specific mortality (CSM) and other-cause mortality (OCM) according to clinical and pathological characteristics of very high-risk cT3b/4 PCa patients treated with RP as the primary treatment option. METHODS In a multi-institutional cohort, 266 patients with very high-risk cT3b/4 PCa treated with RP were identified. All patients underwent RP and pelvic lymph-node dissection. Competing-risk analyses assessed 10-year CSM and OCM before and after stratification for age and Charlson comorbidity index (CCI). RESULTS Overall, 34 (13%) patients died from PCa and 73 (28%) from OCM. Ten-year CSM and OCM rates ranged from 5.6% to 12.9% and from 10% to 38%, respectively. OCM was the leading cause of death in all subgroups. Age and comorbidities were the main determinants of OCM. In healthy men, CSM rate did not differ among age groups (10-year CSM rate for ⩽64, 65-69 and ⩾70 years: 16.2%, 11.5% and 17.1%, respectively). Men with a CCI ⩾1 showed a very low risk of CSM irrespective of age (10-year CSM: 5.6-6.1%), whereas the 10-year OCM rates increased with age up to 38% in men ⩾70 years. CONCLUSION Very high-risk cT3b/4 PCa represents a heterogeneous group. We revealed overall low CSM rates despite the highly unfavorable clinical disease. For healthy men, CSM was independent of age, supporting RP even for older men. Conversely, less healthy patients had the highest risk of dying from OCM while sharing very low risk of CSM, indicating that this group might not benefit from an aggressive surgical treatment. Outcome after RP as the primary treatment option in cT3b/4 PCa patients is related to age and comorbidity status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal laser photocoagulation is an established and successful treatment for a variety of retinal diseases. While being a valuable treatment modality, laser photocoagulation shows the drawback of employing high energy lasers which are capable of physically destroying the neural retina. For reliable therapy, it is therefore crucial to closely monitor the therapy effects caused in the retinal tissue. A depth resolved representation of optical tissue properties as provided by optical coherence tomography may provide valuable information about the treatment effects in the retinal layers if recorded simultaneously to laser coagulation. Therefore, in this work, the use of ultra-high resolution optical coherence tomography to represent tissue changes caused by conventional and selective retinal photocoagulation is investigated. Laser lesions were placed on porcine retina ex-vivo using a 577 nm laser as well as a pulsed laser at 527 nm built for selective treatment of the retinal pigment epithelium. Applied energies were varied to generate lesions best representing the span from under- to overtreatment. The lesions were examined using a custom-designed optical coherence tomography system with an axial resolution of 1.78 μm and 70 kHz Ascan rate. Optical coherence tomography scans included volume scans before and after irradiation, as well as time lapse scans (Mscan) of the lesions. Results show OCT lesion visibility thresholds to be below the thresholds of ophthalmoscopic inspection. With the ultra-high resolution OCT, 42% - 44% of ophthalmoscopically invisible lesions could be detected and lesions that were under- or overexposed could be distinguished using the OCT data.