234 resultados para ± opal-CT
Resumo:
PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.
Resumo:
BACKGROUND: Although urinalysis is simple and inexpensive to perform, the finding of microhaematuria on urinalysis may be unreliable for diagnosing urolithiasis. OBJECTIVE: To evaluate microhaematuria as a diagnostic marker for urolithiasis compared with low-dose unenhanced multidetector computed tomography (MDCT) as the "gold standard". SETTING: A level 1 emergency department in a tertiary referral university teaching hospital. DESIGN: Retrospective analysis. METHODS: A study was undertaken to assess whether the finding of microhaematuria was diagnostic for urolithiasis using a low-dose unenhanced MDCT-based diagnosis as the reference standard by reviewing the records of all patients who presented to the emergency department with colicky flank pain and underwent a CT scan between January 2003 and December 2005. RESULTS: Urolithiasis was present (as defined by low-dose unenhanced MDCT) in 507/638 patients (79%); 341/638 (53%) were true positive for urolithiasis, 76 (12%) were true negative, 55 (9%) were false positive and 166 (26%) were false negative. Microhaematuria as a test for urolithiasis in patients presenting to the emergency department therefore has a sensitivity, specificity, positive predictive value and negative predictive value of 67%, 58%, 86% and 31%, respectively. 58% of the urinalysis results were negative for haematuria in the subset of patients with significant alternative diagnoses. CONCLUSIONS: The sensitivity, specificity and negative predictive value of microhaematuria on urinalysis for urolithiasis using unenhanced MDCT as the reference standard were low. This suggests that, when urolithiasis is clinically suspected, unenhanced MDCT is indicated without urinalysis being a prerequisite.
Resumo:
Purpose: Development of an interpolation algorithm for re‐sampling spatially distributed CT‐data with the following features: global and local integral conservation, avoidance of negative interpolation values for positively defined datasets and the ability to control re‐sampling artifacts. Method and Materials: The interpolation can be separated into two steps: first, the discrete CT‐data has to be continuously distributed by an analytic function considering the boundary conditions. Generally, this function is determined by piecewise interpolation. Instead of using linear or high order polynomialinterpolations, which do not fulfill all the above mentioned features, a special form of Hermitian curve interpolation is used to solve the interpolation problem with respect to the required boundary conditions. A single parameter is determined, by which the behavior of the interpolation function is controlled. Second, the interpolated data have to be re‐distributed with respect to the requested grid. Results: The new algorithm was compared with commonly used interpolation functions based on linear and second order polynomial. It is demonstrated that these interpolation functions may over‐ or underestimate the source data by about 10%–20% while the parameter of the new algorithm can be adjusted in order to significantly reduce these interpolation errors. Finally, the performance and accuracy of the algorithm was tested by re‐gridding a series of X‐ray CT‐images. Conclusion: Inaccurate sampling values may occur due to the lack of integral conservation. Re‐sampling algorithms using high order polynomialinterpolation functions may result in significant artifacts of the re‐sampled data. Such artifacts can be avoided by using the new algorithm based on Hermitian curve interpolation
Resumo:
Computed tomography (CT) has proved to be a valuable investigative tool for mummy research and is the method of choice for examining mummies. It allows for noninvasive insight, especially with virtual endoscopy, which reveals detailed information about the mummy's sex, age, constitution, injuries, health, and mummification techniques used. CT also supplies three-dimensional information about the scanned object. Mummification processes can be summarized as "artificial," when the procedure was performed on a body with the aim of preservation, or as "natural," when the body's natural environment resulted in preservation. The purpose of artificial mummification was to preserve that person's morphologic features by delaying or arresting the decay of the body. The ancient Egyptians are most famous for this. Their use of evisceration followed by desiccation with natron (a compound of sodium salts) to halt putrefaction and prevent rehydration was so effective that their embalmed bodies have survived for nearly 4500 years. First, the body was cleaned with a natron solution; then internal organs were removed through the cribriform plate and abdomen. The most important, and probably the most lengthy, phase was desiccation. After the body was dehydrated, the body cavities were rinsed and packed to restore the body's former shape. Finally, the body was wrapped. Animals were also mummified to provide food for the deceased, to accompany the deceased as pets, because they were seen as corporal manifestations of deities, and as votive offerings. Artificial mummification was performed on every continent, especially in South and Central America.
Resumo:
This paper focuses on the use of multi-detector row dual-energy computed tomography (DECT) in the evaluation of postmortal examinations. The use of dual energy moves postmortem CT to an entirely new dimension of diagnostic sensitivity where contrast in the image is not merely limited to X-ray attenuation differences, but may include elements of functional and tissue characterization. This additional information may be used to improve the benefit postmortem imaging can provide to supplement and simplify the conventional autopsy.
Resumo:
Flat-panel volume computed tomography (fpVCT) is a recent development in imaging. We discuss some of the musculoskeletal applications of a high-resolution flat-panel CT scanner. FpVCT has four main advantages over conventional multidetector computed tomography (MDCT): high-resolution imaging; volumetric coverage; dynamic imaging; omni-scanning. The overall effective dose of fpVCT is comparable to that of MDCT scanning. Although current fpVCT technology has higher spatial resolution, its contrast resolution is slightly lower than that of MDCT (5-10HU vs. 1-3HU respectively). We discuss the efficacy and potential utility of fpVCT in various applications related to musculoskeletal radiology and review some novel applications for pediatric bones, soft tissues, tumor perfusion, and imaging of tissue-engineered bone growth. We further discuss high-resolution CT and omni-scanning (combines fluoroscopic and tomographic imaging).
Resumo:
In a technical development study approved by the institutional ethics committee, the feasibility of fast diffusion-weighted imaging as a replacement for conventional magnetic resonance (MR) imaging sequences (short inversion time inversion recovery [STIR] and T1-weighted spin echo [SE]) and positron emission tomography (PET)/computed tomography (CT) in the detection of skeletal metastases from prostate cancer was evaluated. MR imaging and carbon 11 ((11)C) choline PET/CT data from 11 consecutive prostate cancer patients with bone metastases were analyzed. Diffusion-weighted imaging appears to be equal, if not superior, to STIR and T1-weighted SE sequences and equally as effective as (11)C-choline PET/CT in detection of bone metastases in these patients. Diffusion-weighted imaging should be considered for further evaluation and comparisons with PET/CT for comprehensive whole-body staging and restaging in prostate and other cancers.
Resumo:
INTRODUCTION: In this prospective study we set out to investigate the diagnostic value of [(11)C]choline-PET/CT in patients with suspected lymph node metastases before salvage lymph node dissection. PATIENTS AND METHODS: 15 consecutive patients with rising PSA underwent [(11)C]choline-PET/CT and consecutive open salvage pelvic/retroperitoneal extended lymph node dissection due to uptake of [(11)C]choline in at least 1 lymph node. Mean age was 62.1 (range 53-73). RESULTS: [(11)C]choline-PET/CT results were compared with the histopathology reports and clinical follow-up (mean 13.7 months, range 6-24). Mean time to progression was 23.6 months (range 4-81). [(11)C]choline uptake was observed in nodes along the external and internal and common iliac arteries and in the paraaortic region. A positive histology was reported in 8/15 patients. Only one patient had a PSA nadir of <0.1 ng/ml after salvage surgery. Another patient had stable disease with a PSA of 0.5 ng/ml. Three patients developed bone metastases during follow-up. CONCLUSIONS: This interim analysis indicates that [(11)C]choline-PET/CT may be a useful technique in detection of lymph node metastases when rising PSA occurs after definite prostate cancer therapy. The presented cohort is limited in size, but there is still strong evidence that the patients benefit from [(11)C]choline-PET/CT and consecutive salvage lymph node dissection is rather small.
Resumo:
BACKGROUND AND PURPOSE: Nonconvulsive status epilepticus (NCSE) is associated with a mortality rate of up to 18%, therefore requiring prompt diagnosis and treatment. Our aim was to evaluate the diagnostic value of perfusion CT (PCT) in the differential diagnosis of NCSE versus postictal states in patients presenting with persistent altered mental states after a preceding epileptic seizure. We hypothesized that regional cortical hyperperfusion can be measured by PCT in patients with NCSE, whereas it is not present in postictal states. MATERIALS AND METHODS: Nineteen patients with persistent altered mental status after a preceding epileptic seizure underwent PCT and electroencephalography (EEG). Patients were stratified as presenting with NCSE (n = 9) or a postictal state (n = 10) on the basis of clinical history and EEG data. Quantitative and visual analysis of the perfusion maps was performed. RESULTS: Patients during NCSE had significantly increased regional cerebral blood flow (P > .0001), increased regional cerebral blood volume (P > .001), and decreased (P > .001) mean transit time compared with the postictal state. Regional cortical hyperperfusion was depicted in 7/9 of patients with NCSE by ad hoc analysis of parametric perfusion maps during emergency conditions but was not a feature of postictal states. The areas of hyperperfusion were concordant with transient clinical symptoms and EEG topography in all cases. CONCLUSIONS: Visual analysis of perfusion maps detected regional hyperperfusion in NCSE with a sensitivity of 78%. The broad availability and short processing time of PCT in an emergency situation is a benefit compared with EEG. Consequently, the use of PCT in epilepsy may accelerate the diagnosis of NCSE. PCT may qualify as a complementary diagnostic tool to EEG in patients with persistent altered mental state after a preceding seizure.