311 resultados para fluorescein angiography
Resumo:
Background: This study evaluates cardiovascular risk factors associated with progression of coronary artery disease (CAD) in patientswith silent ischemia followingmyocardial infarction. Hypothesis: Coronary artery disease only progresses slowly with comprehensive risk factor intervention. Methods: A total of 104 of 201 patients (51.7%) of the Swiss Interventional Study on Silent Ischemia Type II (SWISSI II) with baseline and follow-up coronary angiography were included. All patients received comprehensive cardiovascular risk factor intervention according to study protocol. Logistic regression was used to evaluate associationsbetween baseline cardiovascular risk factors and CAD progression. Results: The mean duration of follow-upwas 10.3 ± 2.4 years. At baseline, 77.9% of patients were smokers, 45.2% had hypertension, 73.1% had dyslipidemia, 7.7% had diabetes, and 48.1% had a family history of CAD. At last follow-up, only 27 patients of the initial 81 smokers still smoked, only 2.1% of the patients had uncontrolled hypertension, 10.6%of the patientshad uncontrolled dyslipidemia, and 2.1%of the patientshad uncontrolled diabetes. Coronary artery disease progression was found in up to 81 (77.9%) patients. Baseline diabetes and younger age were associatedwith increased odds of CAD progression.The time intervalbetween baseline and follow-up angiography was also associatedwith CAD progression. Conclusion: Coronary artery disease progressionwas highly prevalent in these patients despite comprehensive risk factor intervention. Further research is needed to optimize treatment of known risk factors and to identify other unknown and potentiallymodifiable risk factors.
Resumo:
AIMS: The effect of cardiac resynchronization therapy (CRT) on right ventricular ejection fraction (RVEF) has not been well studied. Furthermore, it is unclear whether baseline RVEF influences response to CRT. To evaluate the acute and chronic effects of CRT on right ventricular systolic function, and to investigate whether baseline RVEF impacts response to CRT. METHODS AND RESULTS: Forty-four patients with a standard indication for CRT underwent radionuclide angiography at baseline and after at least 6 months' follow-up for measuring RVEF, right ventricular synchrony (using phase analysis), and left ventricular ejection fraction (LVEF). In addition, NYHA functional class and 6-min walking distance (6MWD) were evaluated. There were no significant acute changes in RVEF with CRT. After a mean follow-up of 9 +/- 5 months, RVEF was slightly improved (by 1.9 +/- 5.0% in absolute terms, P = 0.016), and to a lesser extent than LVEF (5.1 +/- 9.0%, P = 0.009 compared with RVEF). Right ventricular dyssynchrony was significantly improved at follow-up (P = 0.016). Patients with a baseline RVEF < or = 0.35 (n = 19) were less likely to improve in NYHA class (P = 0.016), and also tended to improve less in 6MWD and LVEF (P < 0.06). CONCLUSION: Cardiac resynchronization therapy has no acute effect on RVEF, and only slightly improves RVEF at follow-up. Patients with reduced RVEF at baseline were less likely to respond to CRT, indicating that right ventricular systolic dysfunction may play a role in patient selection.
Resumo:
The authors report on bilateral simultaneous knee arthroplasty in a 40-year-old male patient with haemophilia A, high inhibitor titre and an aneurysma spurium of the right popliteal artery. Both knees showed a fixed flexion deformity of 20 degrees. To build up haemostasis, treatment with activated prothrombin complex concentrate (APCC) and recombinant activated factor seven (rFVIIa) was initiated preoperatively. A tourniquet was used on both sides during the operation and factor VIII (FVIII) was administered to further correct coagulopathy. On the eleventh postoperative day the patient complained of increasing pain and pressure in the right knee. An ultrasound suggested aneurysm, which was confirmed by substraction angiography. Under the protection of rFVIIa the aneurysm could be coiled and further rehabilitation was uneventful. At one year post-op the patient presented a range of motion of 90/5/0 degrees for both knees and had returned to full time office work. This case indicates that haemophiliacs with high antibody titre and destruction of both knees can be operated on in one session in order to diminish the operative risk of two consecutive surgical procedures, thus allowing an effective rehabilitation programme. Because of the significant frequency of popliteal aneurysms, preoperative angiography is recommended.
Resumo:
Varicose vein rupture is a rare cause of death, although varicosities are a common pathology. We present three cases of sudden death due to varicose vein rupture. After a review of the literature, the case circumstances and the findings of imaging examination, performed in two cases, are presented. One of them had undergone a post-mortem computed tomography angiography (PMCTA), and one a PMCTA as well as a post-mortem magnetic resonance (PMMR) imaging prior to conventional autopsy. One of the cases presented herein is, to our knowledge, the youngest known fatality due to varicose vein rupture.
Resumo:
In the present paper, the authors describe a case of fatal thoracic impalement in a victim of a road traffic accident, by penetration of a metal handrail. The driver lost control of his car while overtaking three cars. Due to the force of the vehicle collision with a metal railing, the upper cross bar penetrated the front of the car and subsequently the driver was pierced by the center-pillar in the car. Death occurred at the scene of the accident. Postmortem, computed tomography, computed tomography angiography and a magnetic resonance tomography were performed and revealed severe heart destruction and hemorrhage as cause of death. The present case report shows that postmortem imaging might have value as a screening method to decide whether arising forensic questions can be answered just by imaging like in the presented case or if further examinations such as conventional autopsy are required.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
A 55-year-old woman was referred because of diffuse pruritic erythematous lesions and an ischemic process of the third finger of her right hand. She was known to have anaemia secondary to hypermenorrhea. She presented six months before admission with a cutaneous infiltration on the left cubital cavity after a paravenous leakage of intravenous iron substitution. She then reported a progressive pruritic erythematous swelling of her left arm and lower extremities and trunk. Skin biopsy of a lesion on the right leg revealed a fibrillar, small-vessel vasculitis containing many eosinophils.Two months later she reported Raynaud symptoms in both hands, with a persistent violaceous coloration of the skin and cold sensation of her third digit of the right hand. A round 1.5 cm well-delimited swelling on the medial site of the left elbow was noted. The third digit of her right hand was cold and of violet colour. Eosinophilia (19 % of total leucocytes) was present. Doppler-duplex arterial examination of the upper extremities showed an occlusion of the cubital artery down to the palmar arcade on the right arm. Selective angiography of the right subclavian and brachial arteries showed diffuse alteration of the blood flow in the cubital artery and hand, with fine collateral circulation in the carpal region. Neither secondary causes of hypereosinophilia nor a myeloproliferative process was found. Considering the skin biopsy results and having excluded other causes of eosinophilia, we assumed the diagnosis of an eosinophilic vasculitis. Treatment with tacrolimus and high dose steroids was started, the latter tapered within 12 months and then stopped, but a dramatic flare-up of the vasculitis with Raynaud phenomenon occurred. A new immunosuppressive approach with steroids and methotrexate was then introduced. This case of aggressive eosinophilic vasculitis is difficult to classify into the usual forms of vasculitis and constitutes a therapeutic challenge given the resistance to current immunosuppressive regimens.
Resumo:
Cardiogoniometry (CGM), a spatiotemporal electrocardiologic 5-lead method with automated analysis, may be useful in primary healthcare for detecting coronary artery disease (CAD) at rest. Our aim was to systematically develop a stenosis-specific parameter set for global CAD detection. In 793 consecutively admitted patients with presumed non-acute CAD, CGM data were collected prior to elective coronary angiography and analyzed retrospectively. 658 patients fulfilled the inclusion criteria, 405 had CAD verified by coronary angiography; the 253 patients with normal coronary angiograms served as the non-CAD controls. Study patients--matched for age, BMI, and gender--were angiographically assigned to 8 stenosis-specific CAD categories or to the controls. One CGM parameter possessing significance (P < .05) and the best diagnostic accuracy was matched to one CAD category. The area under the ROC curve was .80 (global CAD versus controls). A set containing 8 stenosis-specific CGM parameters described variability of R vectors and R-T angles, spatial position and potential distribution of R/T vectors, and ST/T segment alterations. Our parameter set systematically combines CAD categories into an algorithm that detects CAD globally. Prospective validation in clinical studies is ongoing.
Resumo:
With the increasing use of medical imaging in forensics, as well as the technological advances in rapid prototyping, we suggest combining these techniques to generate displays of forensic findings. We used computed tomography (CT), CT angiography, magnetic resonance imaging (MRI) and surface scanning with photogrammetry in conjunction with segmentation techniques to generate 3D polygon meshes. Based on these data sets, a 3D printer created colored models of the anatomical structures. Using this technique, we could create models of bone fractures, vessels, cardiac infarctions, ruptured organs as well as bitemark wounds. The final models are anatomically accurate, fully colored representations of bones, vessels and soft tissue, and they demonstrate radiologically visible pathologies. The models are more easily understood by laypersons than volume rendering or 2D reconstructions. Therefore, they are suitable for presentations in courtrooms and for educational purposes.
Resumo:
The rapid technical advances in computed tomography have led to an increased number of clinical indications. Unfortunately, at the same time the radiation exposure to the population has also increased due to the increased total number of CT examinations. In the last few years various publications have demonstrated the feasibility of radiation dose reduction for CT examinations with no compromise in image quality and loss in interpretation accuracy. The majority of the proposed methods for dose optimization are easy to apply and are independent of the detector array configuration. This article reviews indication-dependent principles (e.g. application of reduced tube voltage for CT angiography, selection of the collimation and the pitch, reducing the total number of imaging series, lowering the tube voltage and tube current for non-contrast CT scans), manufacturer-dependent principles (e.g. accurate application of automatic modulation of tube current, use of adaptive image noise filter and use of iterative image reconstruction) and general principles (e.g. appropriate patient-centering in the gantry, avoiding over-ranging of the CT scan, lowering the tube voltage and tube current for survey CT scans) which lead to radiation dose reduction.
Resumo:
OBJECTIVE: To evaluate the effect of IL-6 blockade using tocilizumab in inducing remission of arterial large vessel vasculitides (LVV). METHODS: Five consecutive patients with giant-cell arteritis (GCA) and two with Takayasu’s arteritis (TA) were treated by tocilizumab infusions (8 mg/kg). Tocilizumab was given every other week for the first month and once monthly thereafter. Clinical symptoms of disease activity, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level and glucocorticoid (GC) dosage necessary to maintain remission were prospectively assessed. MR angiography was performed to monitor local inflammation. RESULTS: Of the seven patients three were newly diagnosed and four showed GC resistance, i.e. GC could not be lowered to less than 7.5 mg/day. The mean follow-up time was 4.3 months (range 3–7 months). All patients achieved a rapid and complete clinical response and normalisation of the acute phase proteins. Remarkably, prednisone dosage could be reduced within 12 weeks to a mean of 2.5 mg/day (range 0–10 mg/day). No relapse and no drug-related side effects were noted. CONCLUSION: Collectively the data suggest that IL-6 blockade using tocilizumab qualifies as a therapeutic option to induce rapid remission in large vessel vasculitides.
Resumo:
Background—Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results—A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions—Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents.
Resumo:
CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.
Resumo:
PURPOSE: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). RESULTS: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. CONCLUSION: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed.
Resumo:
Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.