117 resultados para electrophoretic mobility


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Do apprenticeships convey mainly general or also firm- and occupation-specific human capital? Specific human capital may allow for specialization gains, but may also lead to allocative inefficiency due to mobility barriers. We analyse the case of Switzerland, which combines a comprehensive, high-quality apprenticeship system with a lightly regulated labour market. To assess human capital transferability after standardized firm-based apprenticeship training, we analyse inter-firm and occupational mobility and their effects on post-training wages. Using a longitudinal data set based on the PISA 2000 survey, we find high inter-firm and low occupational mobility within one year after graduation. Accounting for endogenous changes, we find a negative effect of occupation changes on wages, but no significant wage effect for firm changes. This indicates that occupation-specific human capital is an important component of apprenticeship training and that skills are highly transferable within an occupational field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pharmacokinetic and pharmacodynamic properties of a chiral drug can significantly differ between application of the racemate and single enantiomers. During drug development, the characteristics of candidate compounds have to be assessed prior to clinical testing. Since biotransformation significantly influences drug actions in an organism, metabolism studies represent a crucial part of such tests. Hence, an optimized and economical capillary electrophoretic method for on-line studies of the enantioselective drug metabolism mediated by cytochrome P450 enzymes was developed. It comprises a diffusion-based procedure, which enables mixing of the enzyme with virtually any compound inside the nanoliter-scale capillary reactor and without the need of additional optimization of mixing conditions. For CYP3A4, ketamine as probe substrate and highly sulfated γ-cyclodextrin as chiral selector, improved separation conditions for ketamine and norketamine enantiomers compared to a previously published electrophoretically mediated microanalysis method were elucidated. The new approach was thoroughly validated for the CYP3A4-mediated N-demethylation pathway of ketamine and applied to the determination of its kinetic parameters and the inhibition characteristics in presence of ketoconazole and dexmedetomidine. The determined parameters were found to be comparable to literature data obtained with different techniques. The presented method constitutes a miniaturized and cost-effective tool, which should be suitable for the assessment of the stereoselective aspects of kinetic and inhibition studies of cytochrome P450-mediated metabolic steps within early stages of the development of a new drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computer simulation study describing the electrophoretic separation and migration of methadone enantiomers in presence of free and immobilized (2-hydroxypropyl)-β-CD is presented. The 1:1 interaction of methadone with the neutral CD was simulated by using experimentally determined mobilities and complexation constants for the complexes in a low-pH BGE comprising phosphoric acid and KOH. The use of complex mobilities represents free solution conditions with the chiral selector being a buffer additive, whereas complex mobilities set to zero provide data that mimic migration and separation with the chiral selector being immobilized, that is CEC conditions in absence of unspecific interaction between analytes and the chiral stationary phase. Simulation data reveal that separations are quicker, electrophoretic displacement rates are reduced, and sensitivity is enhanced in CEC with on-column detection in comparison to free solution conditions. Simulation is used to study electrophoretic analyte behavior at the interface between sample and the CEC column with the chiral selector (analyte stacking) and at the rear end when analytes leave the environment with complexation (analyte destacking). The latter aspect is relevant for off-column analyte detection in CEC and is described here for the first time via the dynamics of migrating analyte zones. Simulation provides insight into means to counteract analyte dilution at the column end via use of a BGE with higher conductivity. Furthermore, the impact of EOF on analyte migration, separation, and detection for configurations with the selector zone being displaced or remaining immobilized under buffer flow is simulated. In all cases, the data reveal that detection should occur within or immediately after the selector zone.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Mobile Edge Computing enables the deployment of services, applications, content storage and processing in close proximity to mobile end users. This highly distributed computing environment can be used to provide ultra-low latency, precise positional awareness and agile applications, which could significantly improve user experience. In order to achieve this, it is necessary to consider next-generation paradigms such as Information-Centric Networking and Cloud Computing, integrated with the upcoming 5th Generation networking access. A cohesive end-to-end architecture is proposed, fully exploiting Information-Centric Networking together with the Mobile Follow-Me Cloud approach, for enhancing the migration of content-caches located at the edge of cloudified mobile networks. The chosen content-relocation algorithm attains content-availability improvements of up to 500 when a mobile user performs a request and compared against other existing solutions. The performed evaluation considers a realistic core-network, with functional and non-functional measurements, including the deployment of the entire system, computation and allocation/migration of resources. The achieved results reveal that the proposed architecture is beneficial not only from the users’ perspective but also from the providers point-of-view, which may be able to optimize their resources and reach significant bandwidth savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Failure of transfer of passive immunity (FTPI) in foals is associated with a risk of infection and death. The current diagnostic gold standard is quantification of immunoglobulins using radial immunodiffusion (IgG-RID). Routine diagnosis is often performed using semi-quantitative tests. Concentrations of serum electrophoretic gamma globulins (EGG) and total globulins may be useful to assess FTPI, but few studies have investigated their use. OBJECTIVES: To assess agreement between IgG-RID and EGG, and evaluate the accuracy of total globulin concentration to diagnose FTPI based on both IgG-RID and EGG. STUDY DESIGN: Prospective study. METHODS: 360 serum samples were harvested at 6-24 hours post natum from 60 German Warmblood foals. Concentrations of EGG, IgG-RID and total globulin concentration (calculated from total proteins and albumin) were measured. Agreement between EGG and IgG-RID was assessed using Bland-Altman plots and Passing-Bablok regression. The accuracy of total globulin concentration was assessed using rank correlation and ROC curve analysis. RESULTS: Good agreement was found with slightly lower EGG than IgG-RID concentrations (Bland-Altman systemic bias, -1.9 g/L) which was more pronounced at higher concentrations (regression equation: IgG-RID = -0.78 +1.28xEGG). Correlations between total globulin concentration and EGG, and total globulin concentration and IgG-RID were 0.93 and 0.79, respectively. The area under the curve was 0.982 and 0.952 for EGG <4 g/L and <8 g/L, and 0.953 and 0.899 for IgG-RID <4 g/L and <8 g/L. Sensitivities and specificities of total globulin concentration in the diagnosis of FTPI were comparable to commonly used screening tests, but cut-offs could be selected to achieve sensitivities of >95% with 71.2% (IgG-RID) and 90.5% (EGG) specificity for <4 g/L, and >90% with 66.0% (IgG-RID) and 87.9% (EGG) specificity for <8 g/L. CONCLUSIONS: There is good agreement between EGG and IgG-RID, with slightly more conservative estimates of immunoglobulins obtained using EGG. Total globulins may be a useful and economic quantitative screening test with cut-offs achieving high sensitivities, but analyser-specific cut-offs may be necessary. This article is protected by copyright. All rights reserved. KEYWORDS: IgG; electrophoresis; foal; globulins; horse; radial immunodiffusion. This article is protected by copyright. All rights reserved.