130 resultados para carotid atherosclerosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the last decades, the clinical and research interest in atherosclerosis has been mostly focused on coronary arteries. After the publications of the European Society Guidelines and AHA/ACC Guidelines on Peripheral artery diseases, and of the Registry REduction in Atherothrombosis for Continued Health Registry, there has been an increased interest in atherosclerosis of the lower extremity arteries and its presence in multifocal disease. However, awareness in the general population and the medical community of non-coronary artery diseases, and of its major prognostic implications remain relatively low. The aim of this general review stemming out of an ESC Working Group on Peripheral Circulation meeting in 2011 is to enhance awareness of this complex disease highlighting the importance of the involvement of atherosclerosis at different levels with respect to clinical presentation, diagnosis, and co-existence of the disease in the distinct arterial territories. We also emphasize the need of an interdisciplinary approach to face the broad and complex spectrum of multifocal disease, and try to propose a series of tentative recommendations and measures to be implemented in non-coronary atherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological, clinical, and experimental evidence has accumulated during the last decades suggesting that high-density lipoproteins (HDLs) may protect from atherosclerosis and its clinical consequences. However, more than 55 years after the first description of the link between HDL and heart attacks, many facets of the biochemistry, function, and clinical significance of HDL remain enigmatic. This applies particularly to the completely unexpected results that became available from some recent clinical trials of nicotinic acid and of inhibitors of cholesteryl ester transfer protein (CETP). The concept that raising HDL cholesterol by pharmacological means would decrease the risk of vascular disease has therefore been challenged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI) is unknown. The aim of this study was to quantify the impact of high-intensity statin therapy on plaque burden, composition, and phenotype in non-infarct-related arteries of STEMI patients undergoing primary percutaneous coronary intervention (PCI). METHODS AND RESULTS Between September 2009 and January 2011, 103 STEMI patients underwent intravascular ultrasonography (IVUS) and radiofrequency ultrasonography (RF-IVUS) of the two non-infarct-related epicardial coronary arteries (non-IRA) after successful primary PCI. Patients were treated with high-intensity rosuvastatin (40 mg/day) throughout 13 months and serial intracoronary imaging with the analysis of matched segments was available for 82 patients with 146 non-IRA. The primary IVUS end-point was the change in per cent atheroma volume (PAV). After 13 months, low-density lipoprotein cholesterol (LDL-C) had decreased from a median of 3.29 to 1.89 mmol/L (P < 0.001), and high-density lipoprotein cholesterol (HDL-C) levels had increased from 1.10 to 1.20 mmol/L (P < 0.001). PAV of the non-IRA decreased by -0.9% (95% CI: -1.56 to -0.25, P = 0.007). Patients with regression in at least one non-IRA were more common (74%) than those without (26%). Per cent necrotic core remained unchanged (-0.05%, 95% CI: -1.05 to 0.96%, P = 0.93) as did the number of RF-IVUS defined thin cap fibroatheromas (124 vs. 116, P = 0.15). CONCLUSION High-intensity rosuvastatin therapy over 13 months is associated with regression of coronary atherosclerosis in non-infarct-related arteries without changes in RF-IVUS defined necrotic core or plaque phenotype among STEMI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PRINCIPLES Patients with carotid artery stenosis (CAS) are at risk of ipsilateral stroke and chronic compromise of cerebral blood flow. It is under debate whether the hypo-perfusion or embolism in CAS is directly related to cognitive impairment. Alternatively, CAS may be a marker for underlying risk factors, which themselves influence cognition. We aimed to determine cognitive performance level and the emotional state of patients with CAS. We hypothesised that patients with high grade stenosis, bilateral stenosis, symptomatic patients and/or those with relevant risk factors would suffer impairment of their cognitive performance and emotional state. METHODS A total of 68 patients with CAS of ≥70% were included in a prospective exploratory study design. All patients underwent structured assessment of executive functions, language, verbal and visual memory, motor speed, anxiety and depression. RESULTS Significantly more patients with CAS showed cognitive impairments (executive functions, word production, verbal and visual memory, motor speed) and anxiety than expected in a normative sample. Bilateral and symptomatic stenosis was associated with slower processing speed. Cognitive performance and anxiety level were not influenced by the side and the degree of stenosis or the presence of collaterals. Factors associated with less cognitive impairment included higher education level, female gender, ambidexterity and treated hypercholesterolemia. CONCLUSIONS Cognitive impairment and increased level of anxiety are frequent in patients with carotid stenosis. The lack of a correlation between cognitive functioning and degree of stenosis or the presence of collaterals, challenges the view that CAS per se leads to cognitive impairment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE The use of thrombolysis in patients with minor neurological deficits and large vessel occlusion is controversial. METHODS We compared the outcome of patients with low National Institutes of Health Stroke Scale (NIHSS) scores and large vessel occlusions between thrombolysed and non-thrombolysed patients. RESULTS 88 (1.7%) of 5312 consecutive patients with acute (within 24 h) ischaemic stroke had occlusions of the internal carotid or the main stem of the middle cerebral artery and baseline NIHSS scores ≤5.47 (53.4%) were treated without thrombolysis, and 41 (46.6%) received intravenous thrombolysis, endovascular therapy or both. Successful recanalisation on MR or CT angiography at 24 h was more often observed in thrombolysed than in non-thrombolysed patients (78.9% versus 10.5%; p<0.001). Neurological deterioration (increase of NIHSS score ≥1 compared to baseline) was observed in 22.7% of non-thrombolysed versus 10.3% of thrombolysed after 24 h (p=0.002), in 33.3% versus 12.5% at hospital discharge (p=0.015) and in 41.4% versus 15% at 3 months (p<0.001). Symptomatic intracerebral haemorrhage occurred in two (asymptomatic in five) thrombolysed and in none (asymptomatic in three) non-thrombolysed. Thrombolysis was an independent predictor of favourable outcome (p=0.030) but not survival (p=0.606) at 3 months. CONCLUSIONS Non-thrombolysed patients with mild deficits and large vessel occlusion deteriorated significantly more often within 3 months than thrombolysed patients. Symptomatic intracerebral haemorrhages occurred in less than 5% of patients in both groups. These data suggest that thrombolysis is safe and effective in these patients. Therefore, randomised trials in patients with large vessel occlusions and mild or rapidly improving symptoms are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To assess the literature on carotid calcifications defined from panoramic radiographs (PMX) and concurrent diagnosis of stroke and periodontitis. MATERIALS AND METHODS A literature search screening for publications using search terms such as PMX and carotid calcification, stroke and periodontitis was performed in November 2012. RESULTS A total of 189 articles were retrieved, among which 30 were included in the review. The sensitivity for PMX findings of carotid calcifications (CC) compared to a diagnosis by Doppler sonography varied between 31.1-100%. The specificity for PMX findings of carotid calcifications compared to a diagnosis by Doppler sonography varied between 21.4-87.5%. Individuals with CC findings from PMX have more periodontitis and risk for stroke. CONCLUSIONS There is a shortage of well-designed studies in older dentate individuals assessing the associations between periodontitis and radiographic evidence of CC and in relation to stroke or other cardiovascular diseases. STATEMENT OF CLINICAL RELEVANCE: Carotid calcifications are prevalent in patients with periodontitis and such individuals may have an increased risk for stroke. The absence of signs of carotid calcification on panoramic radiographs is indicative of no calcification of carotid arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the molecular characterization of a microdeletion of approximately 2.5 Mb at 2p11.2 in a female baby with left congenital aural atresia, microtia, and ipsilateral internal carotid artery agenesis. The deletion was characterized by fluorescence in situ hybridization, array comparative genomic hybridization, and whole genome re-sequencing. Among the genes present in the deleted region, we focused our attention on the FOXI3 gene. Foxi3 is a member of the Foxi class of Forkhead transcription factors. In mouse, chicken and zebrafish Foxi3 homologues are expressed in the ectoderm and endoderm giving rise to elements of the jaw as well as external, middle and inner ear. Homozygous Foxi3-/- mice have recently been generated and show a complete absence of the inner, middle, and external ears as well as severe defects in the jaw and palate. Recently, a 7-bp duplication within exon 1 of FOXI3 that produces a frameshift and a premature stop codon was found in hairless dogs. Mild malformations of the outer auditory canal (closed ear canal) and ear lobe have also been noted in a fraction of FOXI3 heterozygote Peruvian hairless dogs. Based on the phenotypes of Foxi3 mutant animals, we propose that FOXI3 may be responsible for the phenotypic features of our patient. Further characterization of the genomic region and the analysis of similar patients may help to demonstrate this point. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Barostim neo ™ system is a novel implantable device that activates the carotid baroreflex. It decreases the sympathetic activity and inhibits the renin system, which results in reduced blood pressure and heart rate. In patients with resistant hypertension, electrically activation of the baroreflex leads to an average decrease in systolic blood pressure of 38, 36, 40 and 53 mmHg at 1, 2, 3 and 4 years, respectively. Additionally, cardiac remodelling with reduced left ventricular mass and posterior wall thickness has been observed in long-term studies. In a limited number of patients with heart failure, baroreflex activation therapy leads to a decrease in muscle sympathetic nerve activity and to improved quality of life and functional capacities. The implantation procedure is safe and associated with risks comparable with those of other active implantable devices. Barostim neo is currently available in several European countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To compare postoperative morphological and rheological conditions after eversion carotid endarterectomy versus conventional carotid endarterectomy using computational fluid dynamics. BASIC METHODS Hemodynamic metrics (velocity, wall shear stress, time-averaged wall shear stress and temporal gradient wall shear stress) in the carotid arteries were simulated in one patient after conventional carotid endarterectomy and one patient after eversion carotid endarterectomy by computational fluid dynamics analysis based on patient specific data. PRINCIPAL FINDINGS Systolic peak of the eversion carotid endarterectomy model showed a gradually decreased pressure along the stream path, the conventional carotid endarterectomy model revealed high pressure (about 180 Pa) at the carotid bulb. Regions of low wall shear stress in the conventional carotid endarterectomy model were much larger than that in the eversion carotid endarterectomy model and with lower time-averaged wall shear stress values (conventional carotid endarterectomy: 0.03-5.46 Pa vs. eversion carotid endarterectomy: 0.12-5.22 Pa). CONCLUSIONS Computational fluid dynamics after conventional carotid endarterectomy and eversion carotid endarterectomy disclosed differences in hemodynamic patterns. Larger studies are necessary to assess whether these differences are consistent and might explain different rates of restenosis in both techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Biomarkers are a promising tool for the management of patients with atherosclerosis, but their variation is largely unknown. We assessed within-subject and between-subject biological variation of biomarkers in peripheral artery disease (PAD) patients and healthy controls, and defined which biomarkers have a favorable variation profile for future studies. METHODS Prospective, parallel-group cohort study, including 62 patients with stable PAD (79% men, 65±7years) and 18 healthy control subjects (44% men, 57±7years). Blood samples were taken at baseline, and after 3-, 6-, and 12-months. We calculated within-subject (CVI) and between-subject (CVG) coefficients of variation and intra-class correlation coefficient (ICC). RESULTS Mean levels of D-dimer, hs-CRP, IL-6, IL-8, MMP-9, MMP-3, S100A8/A9, PAI-1, sICAM-1, and sP-selectin levels were higher in PAD patients than in healthy controls (P≤.05 for all). CVI and CVG of the different biomarkers varied considerably in both groups. An ICC≥0.5 (indicating moderate-to-good reliability) was found for hs-CRP, D-Dimer, E-selectin, IL-10, MCP-1, MMP-3, oxLDL, sICAM-1 and sP-selectin in both groups, for sVCAM in healthy controls and for MMP-9, PAI-1 and sCD40L in PAD patients. CONCLUSIONS Single biomarker measurements are of limited utility due to large within-subject variation, both in PAD patients and healthy subjects. D-dimer, hs-CRP, MMP-9, MMP-3, PAI-1, sP-selectin and sICAM-1 are biomarkers with both higher mean levels in PAD patients and a favorable variation profile making them most suitable for future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.