134 resultados para THORACIC AORTA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To review the incidence, clinical presentation, definite management and 1-year outcome in patients with aorto-oesophageal fistulation (AOF) following thoracic endovascular aortic repair (TEVAR). METHODS International multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2011 with a total caseload of 2387 TEVAR procedures (17 centres). RESULTS Thirty-six patients with a median age of 69 years (IQR 56-75), 25% females and 9 patients (19%) following previous aortic surgery were identified. The incidence of AOF in the entire cohort after TEVAR in the study period was 1.5%. The primary underlying aortic pathology for TEVAR was atherosclerotic aneurysm formation in 53% of patients and the median time to development of AOF was 90 days (IQR 30-150). Leading clinical symptoms were fever of unknown origin in 29 (81%), haematemesis in 19 (53%) and shock in 8 (22%) patients. Diagnosis could be confirmed via computed tomography in 92% of the cases with the leading sign of a new mediastinal mass in 28 (78%) patients. A conservative approach resulted in a 100% 1-year mortality, and 1-year survival for an oesophageal stenting-only approach was 17%. Survival after isolated oesophagectomy was 43%. The highest 1-year survival rate (46%) could be achieved via an aggressive treatment including radical oesophagectomy and aortic replacement [relative risk increase 1.73 95% confidence interval (CI) 1.03-2.92]. The survival advantage of this aggressive treatment modality could be confirmed in bootstrap analysis (95% CI 1.11-3.33). CONCLUSIONS The development of AOF is a rare but lethal complication after TEVAR, being associated with the need for emergency TEVAR as well as mediastinal haematoma formation. The only durable and successful approach to cure the disease is radical oesophagectomy and extensive aortic reconstruction. These findings may serve as a decision-making tool for physicians treating these complex patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dilatation of the ascending aorta is an important sequel in conotruncal anomalies, such as tetralogy of Fallot (TOF) or d-transposition of the great arteries (TGA). We measured dimensions and their progression at different levels of the ascending aorta in 80 patients. In TOF patients, mean z-score for aortic annulus was 1.65 (range -3.16-6.47), for sinus 1.93 (range -2.28-5.39), for st-junction 4.15 (range 0.0-8.18), and for ascending aorta 3.51 (range -1.23-6.36). Over time, annulus z-scores increased in the univariate analysis [0.07/year, 95 % confidence interval (CI) 0.01-0.14; p = 0.02], and this was unique to male patients (0.08/year, 95 % CI 0.00-0.15; p = 0.05). z-scores of the ascending aorta decreased (-0.1/year, 95 % CI -0.18 to -0.02; p = 0.02), and this was confined to patients without aortic regurgitation (AR; -0.09/year, 95 % CI -0.18 to -0.01; p = 0.04). In TGA, mean z-score for the aortic annulus was 2.13 (range -3.71-8.39), for sinus 1.77 (range -3.04-6.69), for st-junction 1.01 (range -5.44-6.71), and for ascending aorta 0.82 (range -4.91-6.46). In bivariate analysis, annulus z-scores decreased in females (-0.14/year, 95 % CI -0.25 to -0.03; p = 0.01) and in patients without AR (-0.07/year, 95 % CI -0.14-0.0; p = 0.03). z-scores of the ascending aorta increased significantly in males (0.08/year, 95 % CI 0.0 to 0.16; p = 0.05) and in patients with AR (0.12/year, 95 % CI 0.03-0.21; p = 0.01). In conclusion, TOF and TGA z-scores of the ascending aorta differ significantly from those of the normal population. Progression of z-scores over time is influenced by diagnosis, sex, and presence of AR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Thoracic epidural analgesia (TEA) has been shown to inhibit detrusor activity in patients undergoing open renal surgery, resulting in clinically relevant post-void residuals. However, the impact of different epidural drug mixtures on urethral sphincter function is not completely elucidated. DESIGN Pooled analysis of an open observational study and a double-blind randomized trial. SETTING Single tertiary centre. SUBJECTS Twenty-eight women without lower urinary tract symptoms and post-void residual <100 mL, who underwent open renal surgery with TEA. METHODS Pooling results in three groups with different epidural regimens (7 with bupivacaine 0.125%, 8 with bupivacaine 0.125% and fentanyl 2 μg/mL, and 13 with bupivacaine 0.1% plus fentanyl 2 μg/mL and epinephrine 2 μg/mL). All women underwent urethral pressure measurements before TEA and during TEA 2-3 days postoperatively. All patients received a TEA placed at the insertion site interspace T 8-9. RESULTS Maximum urethral closure pressure at rest decreased significantly during TEA with bupivacaine alone (median 70 cm H2 O [interquartile range 66-76] to 43 [43-65], P = 0.031) and with bupivacaine/fentanyl/epinephrine (75 cm H2 O [68-78] to 56 [52-75], P = 0.028), whereas with bupivacaine/fentanyl, no significant change could be detected (74 [51-88] vs 67 [46-70], P = 0.156). In all groups, functional profile length at rest was not influenced during TEA. CONCLUSION TEA with bupivacaine and the addition of fentanyl and epinephrine appears to decrease maximum urethral closure pressure at rest in women. The addition of fentanyl alone to bupivacaine may reduce this effect. Thus, the TEA effect on urethral sphincter function seems to depend on the drug mixture administered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyse the results after elective open total aortic arch replacement. METHODS We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate if pre-anaesthetic thoracic radiographs contribute to the anaesthetic management of trauma patients by comparing American Society of Anesthesiologists Physical Status Classification (ASA grade) with and without information from thoracic radiography findings. Case records of 157 dogs and cats being anaesthetized with or without post-traumatic, pre-anaesthetic chest radiographs were retrospectively evaluated for clinical parameters, radiographic abnormalities and anaesthetic protocol. Animals were retrospectively assigned an ASA grade. ASA grades, clinical signs of respiratory abnormalities and anaesthesia protocols were compared between animals with and without chest radiographs. The group of animals without pre-anaesthetic radiographs was anaesthetized earlier after trauma and showed less respiratory abnormalities at presentation. The retrospectively evaluated ASA grade significantly increased with the information from thoracic radiography. Animals with a higher ASA grade were less frequently mechanically ventilated. Pre-anaesthetic radiographs may provide important information to assess the ASA grade in traumatized patients and may therefore influence the anesthesia protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To characterize the clinical findings in dogs and cats that sustained blunt trauma and to compare clinical respiratory examination results with post-traumatic thoracic radiography findings. Design: Retrospective clinical study. Setting: University small animal teaching hospital. Animals, interventions and measurements: Case records of 63 dogs and 96 cats presenting with a history of blunt trauma and thoracic radiographs between September 2001 and May 2003 were examined. Clinical signs of respiratory distress (respiratory rate (RR), pulmonary auscultation) and outcome were compared with radiographic signs of blunt trauma. Results: Forty-nine percent of dogs and 63.5% of cats had radiographic signs attributed to thoracic trauma. Twenty-two percent of dogs and 28% of cats had normal radiographs. Abnormal auscultation results were significantly associated with radiographic signs of thoracic trauma, radiography score and presence and degree of contusions. Seventy-two percent of animals with no other injuries showed signs of thoracic trauma on chest radiographs. No correlation was found between the radiographic findings and outcome, whereas the trauma score at presentation was significantly associated with outcome and with signs of chest trauma but not with the radiography score. Conclusion: Thoracic trauma is encountered in many blunt trauma patients. The RR of animals with blunt trauma is not useful in predicting thoracic injury, whereas abnormal chest auscultation results are indicative of chest abnormalities. Thorough chest auscultation is, therefore, mandatory in all trauma animals and might help in the assessment of necessity of chest radiographs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The population-based effectiveness of thoracic endovascular aortic repair (TEVAR) versus open surgery for descending thoracic aortic aneurysm remains in doubt. METHODS Patients aged over 50 years, without a history of aortic dissection, undergoing repair of a thoracic aortic aneurysm between 2006 and 2011 were assessed using mortality-linked individual patient data from Hospital Episode Statistics (England). The principal outcomes were 30-day operative mortality, long-term survival (5 years) and aortic-related reinterventions. TEVAR and open repair were compared using crude and multivariable models that adjusted for age and sex. RESULTS Overall, 759 patients underwent thoracic aortic aneurysm repair, mainly for intact aneurysms (618, 81·4 per cent). Median ages of TEVAR and open cohorts were 73 and 71 years respectively (P < 0·001), with more men undergoing TEVAR (P = 0·004). For intact aneurysms, the operative mortality rate was similar for TEVAR and open repair (6·5 versus 7·6 per cent; odds ratio 0·79, 95 per cent confidence interval (c.i.) 0·41 to 1·49), but the 5-year survival rate was significantly worse after TEVAR (54·2 versus 65·6 per cent; adjusted hazard ratio 1·45, 95 per cent c.i. 1·08 to 1·94). After 5 years, aortic-related mortality was similar in the two groups, but cardiopulmonary mortality was higher after TEVAR. TEVAR was associated with more aortic-related reinterventions (23·1 versus 14·3 per cent; adjusted HR 1·70, 95 per cent c.i. 1·11 to 2·60). There were 141 procedures for ruptured thoracic aneurysm (97 TEVAR, 44 open), with TEVAR showing no significant advantage in terms of operative mortality. CONCLUSION In England, operative mortality for degenerative descending thoracic aneurysm was similar after either TEVAR or open repair. Patients who had TEVAR appeared to have a higher reintervention rate and worse long-term survival, possibly owing to cardiopulmonary morbidity and other selection bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.