113 resultados para Medical application
Resumo:
The Joint Commission of the Swiss Medical Schools (SMIFK/CIMS) decided in 2000 to establish a Swiss Catalogue of Learning Objectives (SCLO) for undergraduate medical training, which was adapted from a similar Dutch blueprint. A second version of the SCLO was developed and launched in 2008. The catalogue is a prerequisite for the accreditation of the curricula of the six Swiss medical faculties and defines the contents of the Federal Licensing Examination (FLE). Given the evolution of the field of medicine and of medical education, the SMIFK/CIMS has decided to embark on a total revision of the SCLO. This article presents the proposed structure and content of Profiles, a new document which, in the future, will direct the format of undergraduate studies and of the FLE. Profiles stands for the Principal Relevant Objectives for Integrative Learning and Education in Switzerland. It is currently being developed by a group of experts from the six Swiss faculties as well as representatives of other institutions involved in these developments. The foundations of Profiles are grounded in the evolution of medical practice and of public health and are based on up-to-date teaching concepts, such as EPAs (entrustable professional activities). An introduction will cover the concepts and a tutorial will be displayed. Three main chapters will provide a description of the seven 2015 CanMEDS roles, a list of core EPAs and a series of ≈250 situations embracing the most frequent and current conditions affecting health. As Profiles is still a work in progress, it is hoped that this paper will attract the interest of all individuals involved in the training of medical students.
Resumo:
The medical education community is working-across disciplines and across the continuum-to address the current challenges facing the medical education system and to implement strategies to improve educational outcomes. Educational technology offers the promise of addressing these important challenges in ways not previously possible. The authors propose a role for virtual patients (VPs), which they define as multimedia, screen-based interactive patient scenarios. They believe VPs offer capabilities and benefits particularly well suited to addressing the challenges facing medical education. Well-designed, interactive VP-based learning activities can promote the deep learning that is needed to handle the rapid growth in medical knowledge. Clinically oriented learning from VPs can capture intrinsic motivation and promote mastery learning. VPs can also enhance trainees' application of foundational knowledge to promote the development of clinical reasoning, the foundation of medical practice. Although not the entire solution, VPs can support competency-based education. The data created by the use of VPs can serve as the basis for multi-institutional research that will enable the medical education community both to better understand the effectiveness of educational interventions and to measure progress toward an improved system of medical education.
Resumo:
BACKGROUND Correlations between symptom documentation in medical records and patient self-report (SR) vary depending on the condition studied. Patient symptoms are particularly important in urinary tract infection (UTI) diagnosis, and this correlation for UTI symptoms is currently unknown. METHODS This is a cross-sectional survey study in hospitalized patients with Escherichia coli bacteriuria. Patients were interviewed within 24 hours of diagnosis for the SR of UTI symptoms. We reviewed medical records for UTI symptoms documented by admitting or treating inpatient physicians (IPs), nurses (RNs), and emergency physicians (EPs). The level of agreement between groups was assessed using Cohen κ coefficient. RESULTS Out of 43 patients, 34 (79%) self-reported at least 1 of 6 primary symptoms. The most common self-reported symptoms were urinary frequency (53.5%); retention (41.9%); flank pain, suprapubic pain, and fatigue (37.2% each); and dysuria (30.2%). Correlation between SR and medical record documentation was slight to fair (κ, 0.06-0.4 between SR and IPs and 0.09-0.5 between SR and EDs). Positive agreement was highest for dysuria and frequency. CONCLUSION Correlation between self-reported UTI symptoms and health care providers' documentation was low to fair. Because medical records are a vital source of information for clinicians and researchers and symptom assessment and documentation are vital in distinguishing UTI from asymptomatic bacteriuria, efforts must be made to improve documentation.
Resumo:
BACKGROUND Implementation of user-friendly, real-time, electronic medical records for patient management may lead to improved adherence to clinical guidelines and improved quality of patient care. We detail the systematic, iterative process that implementation partners, Lighthouse clinic and Baobab Health Trust, employed to develop and implement a point-of-care electronic medical records system in an integrated, public clinic in Malawi that serves HIV-infected and tuberculosis (TB) patients. METHODS Baobab Health Trust, the system developers, conducted a series of technical and clinical meetings with Lighthouse and Ministry of Health to determine specifications. Multiple pre-testing sessions assessed patient flow, question clarity, information sequencing, and verified compliance to national guidelines. Final components of the TB/HIV electronic medical records system include: patient demographics; anthropometric measurements; laboratory samples and results; HIV testing; WHO clinical staging; TB diagnosis; family planning; clinical review; and drug dispensing. RESULTS Our experience suggests that an electronic medical records system can improve patient management, enhance integration of TB/HIV services, and improve provider decision-making. However, despite sufficient funding and motivation, several challenges delayed system launch including: expansion of system components to include of HIV testing and counseling services; changes in the national antiretroviral treatment guidelines that required system revision; and low confidence to use the system among new healthcare workers. To ensure a more robust and agile system that met all stakeholder and user needs, our electronic medical records launch was delayed more than a year. Open communication with stakeholders, careful consideration of ongoing provider input, and a well-functioning, backup, paper-based TB registry helped ensure successful implementation and sustainability of the system. Additional, on-site, technical support provided reassurance and swift problem-solving during the extended launch period. CONCLUSION Even when system users are closely involved in the design and development of an electronic medical record system, it is critical to allow sufficient time for software development, solicitation of detailed feedback from both users and stakeholders, and iterative system revisions to successfully transition from paper to point-of-care electronic medical records. For those in low-resource settings, electronic medical records for integrated care is a possible and positive innovation.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.
Resumo:
The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital) is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET) radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.
Resumo:
For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.