214 resultados para INTRAVASCULAR ULTRASOUND ELASTOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We estimated the diagnostic accuracy of ultrasound detrusor thickness measurement for BOO and investigated whether this method can replace PFS for the diagnosis of BOO in some patients with lower urinary tract symptoms. MATERIALS AND METHODS: Detrusor thickness was measured by linear ultrasound (7.5 MHz) at a filling volume of greater than 50% of cystometric capacity in 102 men undergoing PFS for LUTS. All patients with prior treatment for bladder outlet obstruction and those with underlying neurological disorders were excluded from analysis. Detrusor thickness was correlated with PFS data. Obstruction was defined according to the Abrams-Griffiths nomogram. RESULTS: Detrusor thickness was significantly higher (p <0.0001) in obstructed (61 cases, median detrusor thickness 2.7 mm, IQR 2.4 to 3.3) compared to unobstructed (18 cases, median detrusor thickness 1.7 mm, IQR 1.5 to 2) as well as equivocal (23 cases, median detrusor thickness 1.8 mm, IQR 1.5 to 2.2) cases. A weak to medium Spearman correlation was found between detrusor thickness and PFS parameters. For a diagnosis of BOO, detrusor thickness of 2.9 mm or greater had a positive predictive value of 100%, a negative predictive value of 54%, specificity of 100% and sensitivity of 43%. ROC analysis revealed that detrusor thickness had a high predictive value for BOO with an AUC of 0.88 (95% CI 0.81-0.94). CONCLUSIONS: In men with LUTS without prior treatment and/or neurological disorders, ultrasonographically assessed detrusor thickness 2.9 mm or greater has a high predictive value for BOO and can replace PFS for the diagnosis of BOO. However, this cutoff value needs to be validated in a larger study population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Preoperative chemoradiotherapy is generally recommended for locally advanced esophageal cancer (clinical stage T3 or T4 or nodal positive disease) but not for early cancer (clinical stage T0 to T2, N0). EUS has been described as the most accurate method to distinguish between early and locally advanced stage in several studies. Recently however, the high accuracy of EUS (90% or higher) was questioned by some investigators. This raises the issue whether the results of studies focused on EUS accuracy may be directly translated into daily clinical practice. Aim & Methods: The aim of this retrospective analysis was to assess the accuracy of preoperative EUS to distinguish between early and locally advanced esophageal cancer in daily clinical practice outside a study setting. EUS was performed by several investigators, including trainees in one university hospital. For this purpose, EUS reports and patient files (medical and surgical) including histological reports of 300 consecutive pts with esophageal tumors were reviewed. In pts with adenocarcinoma or squamous cell cancer and surgical resection without previous radio-/chemotherapy, EUS tumor staging was compared with histological diagnosis. Results: Out of the 300 consecutive pts with esophageal tumor and EUS 102 pts had esophageal surgery after EUS-staging without any radio-/chemotherapy. In 93 pts oesophageal cancer was confirmed, whereas 9 had other tumors. The mean age was 65 years (range 27-89), sex ratio female:male was 1:3.2. To distinguish between early and late tumor stage, the accuracy was 85%. The sensitivity and specificity for early cancer was 59%, and 93%, respectively. The diagnostic accuracy for local tumor spread was 90%, 90%, 68%, 69%, 89% for pT0, pT1, pT2, pT3 and pT4 lesions, respectively. The overall accuracy for T-stage was 74%. For pN-positive staging the accuracy of EUS was 73%. Conclusion: In daily clinical practice, the accuracy of EUS in assessing esophageal tumor staging is lower than in specific studies focusing on EUS accuracy. Mainly early esophageal cancer stages were overstaged. Thus, the implementation of recommendations for diagnostic work-up of esophageal cancer patients resulting from highly specific studies should consider the appropriate clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the score for disseminated intravascular coagulation (DIC) recently published by the International Society for Thrombosis and Haemostasis (ISTH) in a well-defined series of sepsis patients. Thirty-two patients suffering from severe sepsis and eight patients with septic shock were evaluated following the ISTH DIC score. Fibrin monomer and D-dimer were chosen as fibrin-related markers (FRM), respectively. DIC scores for nonsurvivors (n = 13) as well as for septic shock patients were higher (P < 0.04) compared with survivors and patients with severe sepsis, respectively. Using fibrin monomer and D-dimer, 30 and 25% of patients suffered from overt DIC. Overt DIC was associated with significantly elevated thrombin-antithrombin complexes and plasminogen activator inhibitor type-1 levels as well as with significantly lower factor VII clotting activity. Patients with overt DIC had a significantly higher risk of death and of developing septic shock. Since more than 95% of the sepsis patients had elevated FRM, the DIC score was strongly dependent on prolongation of the prothrombin time and platelet counts. The ISTH DIC score is useful to identify patients with coagulation activation, predicting fatality and disease severity. It mainly depends on the prolongation of the prothrombin time and platelet counts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sonography is an important diagnostic tool to examine the gastrointestinal tract of dogs with chronic diarrhea. Two-dimensional grayscale ultrasound parameters to assess for various enteropathies primarily focus on wall thickness and layering. Mild, generalized thickening of the intestinal wall with maintenance of the wall layering is common in inflammatory bowel disease. Quantitative and semi-quantitative spectral Doppler arterial waveform analysis can be utilized for various enteropathies, including inflammatory bowel disease and food allergies. Dogs with inflammatory bowel disease have inadequate hemodynamic responses during digestion of food. Dogs with food allergies have prolonged vasodilation and lower resistive and pulsatility indices after eating allergen-inducing foods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a standardized procedure for examination of the canine abdomen using endoscopic ultrasound and to describe the organs and structures that could be identified transgastrically. The abdomen of four healthy dogs and two cadavers were examined with endoscopic ultrasound. Five anatomic landmarks were used for standardized imaging of the cranial abdomen. These were the portal vein, splenic head and body, duodenum, left kidney, and aorta. High-resolution images of the following organs and structures could be made: distal esophagus, gastric wall from the cardia to the pylorus, liver, caudal vena cava, hepatic lymph nodes, liver hilus, and associated vessels, trifurcation of the celiac artery as well as the path of its branches and the left pancreatic limb and body. Structures that were more difficult to image were the distal duodenum and right pancreatic limb, the entire jejunum, ileum, and cecum as well as the tail of the spleen. Endoscopic ultrasound allowed excellent visualization of the gastric wall and regional structures without interference with gas artefacts. Centrally located organs such as the pancreas could be well examined transgastrically with endoscopic ultrasound without interference by overlying intestinal segments as is common with transabdominal ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal cancer represents accounts for approximately 3% of all adult malignancies with a rising incidence. Incidental diagnosis is mostly based upon ultrasound (US). US and Computed tomography (CT) are the standard imaging modalities for detecting renal cell cancer (RCC). Differentiation between malignant and benign renal tumors is of utmost importance. Contrast enhanced ultrasound (CUS) seems to be a promising new diagnostic option for diagnosis and preoperative treatment planning for patients with renal cancer. It is an additional examination to baseline ultrasound and CT. We report a case of a 37-year-old woman with a papillary renal cell cancer in which CUS helped to differentiate dignity of the tumor. CUS is an additional examination to baseline ultrasound and CT. It is a less invasive technique than contrast enhanced CT and shows even slight tumor blood flow. In addition it may allow a more rapid diagnosis, because of its bedside availability.