110 resultados para Exhaled breath


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The implementation of complementary and alternative therapies into conventional treatment schemes is gaining popularity. However, their use is widely depending on patients’ drive. This case-report focuses on a patient’s experience of the integration of WATSU (WaterShiatsu) in rehabilitative care. Methods: Patient: A 52 year old woman survived a severe motorcycle-accident in which she sustained several fractures on the right side of her body, including ribs, pelvis, and femur. After discharge from stationary care, she independently added WATSU to her rehabilitative regimen. Treatment approach: WATSU is a passive form of hydrotherapy in warm water that aims at relaxation, pain relief, and a sense of secureness. In the reported case, an experienced WATSU-therapist who is also trained in physiotherapy and psychosomatics delivered weekly sessions of one hour duration. Measures used: Qualitative data were collected by patient’s diary. Also the therapist’s notes including The Patient Specific Functional Scale (PSFS) were considered. Results: The patient associated WATSU with trunk mobilization (followed by ameliorated breath), reconciliation with her body, and emotional discharge. She ascribed WATSU lasting effects on her body-image. The therapist employed WATSU for careful mobilization and to equalize awareness throughout the body. The PSFS displayed continuous improvement in all categories except usage of public transportation. Due to complications (elevated inflammation markers) only 6 of 8 scheduled sessions were administered. Conclusions: WATSU was experienced helpful in approaching conditions that are difficult to address by conventional physiotherapy. In early rehabilitation, additional medical/physiotherapeutic skills of contributing complementary therapists are advocated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prematurity is the most common disruptor of lung development. The aim of our study was to examine the function of the more vulnerable peripheral airways in former preterm children by multiple-breath washout (MBW) measurements.86 school-aged children, born between 24 and 35 weeks of gestation and 49 term-born children performed nitrogen MBW. Lung clearance index (LCI), and slope III-derived Scond and Sacin were assessed as markers for global, convection-dependent and diffusion-convection-dependent ventilation inhomogeneity, respectively.We analysed the data of 77 former preterm (mean (range) age 9.5 (7.2-12.8) years) and 46 term-born children (mean age 9.9 (6.0-15.9) years). LCI and Sacin did not differ between preterm and term-born children. Scond was significantly elevated in preterm compared to term-born participants (mean difference z-score 1.74, 95% CI 1.17-2.30; p<0.001), with 54% of former preterm children showing elevated Scond. In multivariable regression analysis Scond was significantly related only to gestational age (R(2)=0.37).Normal Sacin provides evidence for a functionally normal alveolar compartment, while elevated Scond indicates impaired function of more proximal conducting airways. Together, our findings support the concept of continued alveolarisation, albeit with "dysanaptic" lung growth in former preterm children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM Our aim was to challenge the validity of these software algorithms. METHODS We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold). Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.