151 resultados para Carotid arteries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this analysis was to compare vasoreactive properties of internal thoracic arteries (ITA) grafts from diabetic (DM) to those of non-diabetic (ND) patients. Ring segments of ITA, taken from patients undergoing coronary artery bypass grafting, were suspended in organ bath chambers filled with modified Krebs-Henseleit solution and contractile responses to potassium chloride (KCl), noradrenaline (NA), endothelin-1 (ET-l), and endothelium-dependent relaxant responses to acetylcholine (ACH) were recorded isometrically. The receptor-mediated agonists NA and ET-1 stimulated ITA from both groups within similar concentration ranges while ITA from DM patients proved to be significantly more sensitive to KCl than ITA from ND. Furthermore, maximal contractile responses indicated that KCl (3.79 +/- 0.30 g, n = 7 in DM and 2.50 +/- 0.23 g, n = 29 in ND, P < 0.05) evoked significantly higher responses in ITA from DM as compared to the ND control group while both NA and ET-l stimulated ITA from both groups with similar efficacies. Endothelium-dependent relaxant responses to ACH proved to be similar in both groups when expressed as percentages of the pre-existing tone. The present data support the contention that in comparison to ND controls arteries from DM patients are more sensitive to depolarization but endothelial dysfunction is less frequent in human ITA than expected from observations in systemic vascular beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent dramatic changes in surgical training resulting from working-hour regulations may lead to lack of competence. Traditionally, carotid surgery has been the domain of specialists. This study was designed to compare the outcome of carotid endarterectomy performed by vascular surgical trainees versus vascular surgeon (VS). METHODS: A retrospective study of 1,379 consecutive patients who underwent carotid endarterectomy as the sole procedure under local or general anesthesia (from 1995-2004) was performed. All patients were admitted to the intensive care unit for 24 hours. Trainees performed 475 (34.5%) and vascular specialists performed 904 (65.5%) operations. RESULTS: Patient characteristics with regard to preoperative neurological status were similar. Trainees operated on 61.4% symptomatic patients and VS on 56.8% (P = 0.09). Shunt use did not differ (16% trainee vs. 17.8% VS). Clamping time and total operating time were longer among trainees (41.9 vs. 33.5 min, P < 0.001; and 121.2 vs. 101.8 min, P < 0.001, respectively). Postoperative stroke and death rates (3.2% vs. 3.1% and 0.4% vs. 0.9%, respectively) did not differ. Peripheral nerve complications were more common among trainees (12.2% vs. 6.5%; P < 0.0001); 99.6% of these nerve injuries had resolved at 3 months' follow-up. CONCLUSIONS: Carotid endarterectomy can be performed safely by a trainee vascular surgeon when assisted and supervised by a specialist vascular surgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To prospectively compare the diagnostic accuracy of steady-state, high-spatial-resolution magnetic resonance (MR) angiography of the lower leg, performed with a blood pool contrast agent, with selective digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To examine the prevalence of sustained ventricular tachycardia (VT) and sudden death (SD) in adults with atrial repair of transposition of the great arteries (TGA) and to determine associated risk factors. METHODS AND RESULTS: In a single-centre review, we studied the outcome of 149 adults (mean age 28 +/- 7 years) who had undergone a Mustard operation for TGA. During a mean follow-up of 9 +/- 6 years, sustained VT and/or SD occurred in 9% (13/149) of the cohort. Sustained VT/SD was more likely to occur in patients with associated anatomic lesions [hazard ratio (HR) 4.9, 95% CI 1.5-16.0], with NYHA class >or=III (HR 9.8, 95% CI 3.0-31.6) and with an impaired subaortic right ventricular (RV) ejection fraction (EF) (HR 2.2, 95% CI 1.2-4.0 per 10% decrease in EF). There was an inverse correlation between the RV-EF and both age and QRS duration. Patients with a QRS duration >or=140 ms were at highest risk of sustained VT/SD (HR 13.6, 95% CI 2.9-63.4). Atrial tachyarrhythmia was detected in 66 (44%) patients, but was not a statistically significant predictor of sustained VT/SD in our adult population (HR 2.7, 95% CI 0.6-13.0). CONCLUSION: Sustained VT/SD in adults after a Mustard operation for TGA are more common than previously described. Age, systemic ventricular function, and QRS duration are interrelated and are associated with VT/SD. A QRS duration >or=140 ms helps to identify the high risk patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: No randomized study has yet compared efficacy and safety of aspirin and anticoagulants in patients with spontaneous dissection of the cervical carotid artery (sICAD). METHODS: Prospectively collected data from 298 consecutive patients with sICAD (56% men; mean age 46 +/- 10 years) treated with anticoagulants alone (n = 202) or aspirin alone (n = 96) were retrospectively analyzed. Admission diagnosis was ischemic stroke in 165, TIA in 37, retinal ischemia in 8, and local symptoms and signs (headache, neck pain, Horner syndrome, cranial nerve palsy) in 80 patients, while 8 patients were asymptomatic. Clinical follow-up was obtained after 3 months by neurologic examination (97% of patients) or structured telephone interview. Outcome measures were 1) new cerebral ischemic events, defined as ischemic stroke, TIA, or retinal ischemia, 2) symptomatic intracranial hemorrhage, and 3) major extracranial bleeding. RESULTS: During follow-up, ischemic events were rare (ischemic stroke, 0.3%; TIA, 3.4%; retinal ischemia, 1%); their frequency did not significantly differ between patients treated with anticoagulants (5.9%) and those treated with aspirin (2.1%). The same was true for hemorrhagic adverse events (anticoagulants, 2%; aspirin, 1%). New ischemic events were significantly more frequent in patients with ischemic events at onset (6.2%) than in patients with local symptoms or asymptomatic patients (1.1%). CONCLUSIONS: Within the limitations of a nonrandomized study, our data suggest that frequency of new cerebral and retinal ischemic events in patients with spontaneous dissection of the cervical carotid artery is low and probably independent of the type of antithrombotic treatment (aspirin or anticoagulants).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared continuous pullback from the left anterior descending artery (LAD) with pullback from the circumflex artery (CX) for the assessment of the left main coronary artery (LMCA) by intravascular ultrasound (IVUS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative characterisation of carotid atherosclerosis and classification into symptomatic or asymptomatic is crucial in planning optimal treatment of atheromatous plaque. The computer-aided diagnosis (CAD) system described in this paper can analyse ultrasound (US) images of carotid artery and classify them into symptomatic or asymptomatic based on their echogenicity characteristics. The CAD system consists of three modules: a) the feature extraction module, where first-order statistical (FOS) features and Laws' texture energy can be estimated, b) the dimensionality reduction module, where the number of features can be reduced using analysis of variance (ANOVA), and c) the classifier module consisting of a neural network (NN) trained by a novel hybrid method based on genetic algorithms (GAs) along with the back propagation algorithm. The hybrid method is able to select the most robust features, to adjust automatically the NN architecture and to optimise the classification performance. The performance is measured by the accuracy, sensitivity, specificity and the area under the receiver-operating characteristic (ROC) curve. The CAD design and development is based on images from 54 symptomatic and 54 asymptomatic plaques. This study demonstrates the ability of a CAD system based on US image analysis and a hybrid trained NN to identify atheromatous plaques at high risk of stroke.