226 resultados para Abdominal closure
Resumo:
INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. MATERIALS AND METHODS: One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. RESULTS: Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). CONCLUSION: Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.
Resumo:
OBJECTIVE: Anemia is a common comorbid condition in various inflammatory states and an established predictor of mortality in patients with chronic heart failure, ischemic heart disease, and end-stage renal disease. The present study of patients with abdominal aortic aneurysm (AAA) undergoing endovascular repair (EVAR) assessed the relationships between baseline hemoglobin concentration and AAA size, as well as anemia and long-term survival. METHODS: Between March 1994 and November 2006, 711 patients (65 women, mean age 75.8 +/- 7.8 years) underwent elective EVAR. Anemia was defined as a hemoglobin level <13 g/dL in men and <12 g/dL in women. Post-EVAR mean follow-up was 48.3 +/- 32.0 months. Association of hemoglobin level with AAA size was assessed with multiple linear regression. Mortality was determined with use of the internet-based Social Security Death Index and the electronic hospital record. Kaplan-Meier survival curves of anemic and nonanemic patient groups were compared by the log-rank method. Multivariable logistic regression models were used to determine the influence of anemia on vital status after EVAR. RESULTS: A total of 218/711 (30.7%) of AAA patients undergoing EVAR had anemia at baseline. After adjustment for various risk factors, hemoglobin level was inversely related to maximum AAA diameter (beta: - .144, 95%-CI: -1.482 - .322, P = .002). Post-EVAR survival was 65.5% at 5 years and 44.4% at 10 years. In long-term follow-up, survival was significantly lower in patients with anemia as compared to patients without anemia (P < .0001 by log-rank). Baseline hemoglobin levels were independently related to long-term mortality in multivariable Cox regression analysis adjusted for various risk factors (adjusted HR: 0.866, 95% CI: .783 to .958, P = .005). Within this model, statin use (adjusted HR: .517, 95% CI: .308 to .868, P = .013) was independently related to long-term survival, whereas baseline AAA diameter (adjusted HR: 1.022, 95% CI: 1.009 to 1.036, P = .001) was an independently associated with increased mortality. CONCLUSIONS: Baseline hemoglobin concentration is independently associated with AAA size and reduced long-term survival following EVAR. Thus, the presence or absence of anemia offers a potential refinement of existing risk stratification instruments.
Resumo:
The patient with abdominal aortic aneurysm (AAA) commonly is a nondiabetic, white man with a history of smoking. Moreover, AAA represents a leading cause of death in elderly men in Western countries. The purpose of this manuscript is to review current evidence as to the pathobiology of AAA as well as potential future drug targets to prevent progression of AAA.
Resumo:
OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.
Resumo:
BACKGROUND: The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. METHODS: On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. RESULTS: CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. CONCLUSIONS: In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure.
Resumo:
Migraine is a recurrent disabling disorder predominantly affecting middle-aged women. Migraine occurs with or without aura symptoms. Several studies have shown an increased prevalence of right-to-left shunts (RLSs) in migraine with aura. The overwhelming majority of these shunts were due to a patent foramen ovale (PFO). Furthermore, migraine with aura is more prevalent in clinical entities associated with a RLS, e.g. cryptogenic stroke, decompression illness in divers, or in patients with hereditary hemorrhagic teleangiectasia and pulmonary arteriovenous fistulas. Retrospective studies have consistently shown that shunt closure was associated with a significant reduction in migraine frequency. Its beneficial effect seemed to exceed the efficacy of conventional migraine therapy. Several randomized clinical trials to prospectively assess the benefit of shunt closure in migraine patients have been initiated. The only one completed, the MIST trial (Migraine Intervention with STARFLEX Technology), showed a significant reduction of migraine with aura after device implantation, compared with controls. However, the benefit of PFO closure was more modest than expected. This review recapitulates the current data regarding PFO closure and migraine with aura and summarizes in brief the current knowledge regarding migraine pathophysiology and the link to a RLS.
Resumo:
A patent foramen ovale (PFO) is a common finding present in 25% of the population. A relationship between PFO and several clinical conditions such as stroke, migraine, platypnea-orthodeoxia syndrome, neurological decompression illness in divers, high altitude pulmonary edema, sleep apnea, and economy class syndrome have been documented. Observational non-randomized studies have shown percutaneous PFO closure more effective than medical treatment for stroke prevention, in particular in patients with complete closure as well as in patients with more than one cerebrovascular event at baseline. In the case of migraine, PFO closure has been shown to result in a marked reduction in migraine burden or migraine days. PFO anatomy, epidemiological data on associated clinical conditions, comparison between percutaneous closure and medical treatment, as well as the technical aspect of the procedure are described in this review.
Resumo:
PURPOSE: To elucidate the association of impaired pulmonary status (IPS) and diabetes mellitus (DM) with clinical outcome and the incidences of aortic neck dilatation and type I endoleak after elective endovascular infrarenal aortic aneurysm repair (EVAR). METHODS: In 164 European institutions participating in the EUROSTAR registry, 6383 patients (5985 men; mean age 72.4+/-7.6 years) underwent EVAR. Patients were divided into patients without versus with IPS or with/without DM. Clinical assessment and contrast-enhanced computed tomography (CT) were performed at 1, 3, 6, 12, 18, and 24 months and annually thereafter. Cumulative endpoint analysis comprised death, aortic rupture, type I endoleak, endovascular reintervention, and surgical conversion. RESULTS: Prevalence of IPS was 2733/6383 (43%) and prevalence of DM was 810/6383 (13%). Mean follow-up was 21.1+/-18.4 months. Thirty-day mortality, AAA rupture, and conversion rates did not differ between patients with versus without IPS and between patients with versus without DM. All-cause and AAA-related mortality, respectively, were significantly higher in patients with IPS compared to patients with normal pulmonary status (31.0% versus 19.0%, p<0.0001 and 6.8% versus 3.3%, p = 0.0057) throughout follow-up. In multivariate analysis adjusted for smoking, age, gender, comorbidities, fitness for open repair, co-existing common iliac aneurysm, neck and aneurysm size, arterial angulations, aneurysm classification, endograft oversizing >or=15%, and type of stent-graft, the presence of IPS was not associated with significantly higher rates of aortic neck dilatation (30.6% versus 38.0%, p>0.05) and did not influence cumulative rates of type I endoleak, endovascular reintervention, or conversion to open surgery (p>0.05). Similarly, the presence of DM did not influence the above-mentioned study endpoints. CONCLUSION: In contrast to observations regarding the natural course of AAAs, impaired pulmonary status does not negatively influence aortic neck dilatation, while the presence of diabetes does not protect from these dismal events after EVAR.
Resumo:
Because of superior soft-tissue contrast compared to other imaging techniques, non-invasive abdominal magnetic resonance imaging (MRI) is ideal for monitoring organ regeneration, tissue repair, cancer stage, and treatment effects in a wide variety of experimental animal models. Currently, sophisticated MR protocols, including technically demanding procedures for motion artefact compensation, achieve an MRI resolution limit of < 100 microm under ideal conditions. However, such a high spatial resolution is not required for most experimental rodent studies. This article describes both a detailed imaging protocol for MR data acquisition in a ubiquitously and commercially available 1.5 T MR unit and 3-dimensional volumetry of organs, tissue components, or tumors. Future developments in MR technology will allow in vivo investigation of physiological and pathological processes at the cellular and even the molecular levels. Experimental MRI is crucial for non-invasive monitoring of a broad range of biological processes and will further our general understanding of physiology and disease.
Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.